Detection of tachyarrhythmia with a dual chamber defibrillator connected to a defibrillation lead with a free-floating atrial bipole

被引:0
|
作者
Schuchert, A
Lemke, B
Schmitz, D
Wiegand, U
Bondke, HJ
Zerm, T
Aydin, MA
Meinertz, T
机构
[1] Univ Hosp Hamburg Eppendorf, Dept Cardiol, Hamburg, Germany
[2] BG Clin Bergmannsheil, Bochum, Germany
[3] St Johannis Hosp, Dortmund, Germany
[4] Univ Lubeck, Lubeck, Germany
[5] Univ Hosp Charite, Berlin, Germany
[6] Karl Gustav Univ, Dresden, Germany
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
下载
收藏
页码:357 / 357
页数:1
相关论文
共 26 条
  • [21] Optimization of atrial defibrillation pathways without use of coronary sinus leads in patients receiving medtronic 7250 dual chamber defibrillator (Jewel AF)
    Chaudhry, GM
    Warman, E
    Casavant, D
    Satti, SD
    Vinch, CS
    Pacetti, P
    Marchese, T
    Haffajee, CI
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 104A - 104A
  • [22] Subclinical atrial fibrillation detection with a floating atrial sensing dipole in single lead implantable cardioverter-defibrillator systems: Results of the SENSE trial
    Thomas, George
    Choi, Daniel Y.
    Doppalapudi, Harish
    Richards, Mark
    Iwai, Sei
    Daoud, Emile G.
    Houmsse, Mahmoud
    Kanagasundram, Arvindh N.
    Mainigi, Sumeet K.
    Lubitz, Steven A.
    Cheung, Jim W.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (10) : 1994 - 2001
  • [23] Comparison study on sensing and identification of Single-Lead Atrial Sensing System, Single-Chamber and Dual-Chamber Implantable Cardioverter Defibrillator System
    Long, Qilin
    Sun, Jie
    Dong, Jianting
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 72 (16) : C135 - C135
  • [24] Preliminary assessment of a new algorithm for automatic detection of fast atrial fibrillation in a dual-chamber implantable cardioverter-defibrillator
    Montenero, AS
    Nitzsche, R
    DeChillou, C
    Iscolo, N
    Sadoul, N
    Aliot, E
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 915 - 920
  • [25] Comparison of a Novel, Single-Lead Atrial Sensing System With a Dual-Chamber Implantable Cardioverter-Defibrillator System in Patients Without Antibradycardia Pacing Indications Results of a Randomized Study
    Sticherling, Christian
    Zabel, Markus
    Spencker, Sebastian
    Meyerfeldt, Udo
    Eckardt, Lars
    Behrens, Steffen
    Niehaus, Michael
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (01): : 56 - 63
  • [26] Feasibility of dual-chamber (DDD) pacing via a single-pass (VDD) pacing lead employing a floating atrial ring (dipole): Case series, future considerations, and refinements
    Kassotis, J
    Voigt, L
    Mongwa, M
    Reddy, CVR
    ANGIOLOGY, 2005, 56 (03) : 323 - 329