Calibration and characterization of a digital camera for bidirectional reflectance distribution function retrieval of vicarious calibration sites

被引:5
|
作者
Czapla-Myers, Jeffrey S. [1 ]
Thome, Kurtis J. [1 ]
Biggar, Stuart F. [1 ]
机构
[1] Univ Arizona, Remote Sensing Grp, Coll Opt Sci, Tucson, AZ 85721 USA
来源
关键词
Digital camera; calibration; radiometry; bidirectional reflectance; ABSOLUTE RADIOMETRIC CALIBRATION; LANDSAT-7 ETM+; TERRA ASTER; BRDF DATA; MODIS; INSTRUMENT; SENSORS; SYSTEM; MISR;
D O I
10.1117/1.3116662
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This work describes the calibration and characterization of a commercial digital camera that is being evaluated as a potential inexpensive imaging system to measure the bidirectional reflectance factor of the test site surfaces that are used by the Remote Sensing Group for the ground-based vicarious calibration of airborne and spaceborne systems. The main advantage to using a lightweight digital camera in combination with a fisheye lens is that a test site can be simultaneously spatially and spectrally sampled with greater ease. The motivation for using an inexpensive, lightweight digital camera to measure surface bidirectional distribution factor is the ability to spatially sample many points on the ground. An additional benefit to such cameras is their ability to operate without the need for cooling, which was required on a previous camera system developed at the Remote Sensing Group. Laboratory measurements include the gain and offset, spectral responsivity, linearity, cosine response, and point spread function. The results show that the uniformity of the Nikon detector array ranges from 0.7%-1.2%. The spectral bandwidth is approximately 90 nm for the blue channel, and 110 nm for the green, and 75 nm for the red channel. Linearity measurements show that the camera responsivity is nonlinear due to the internal image-processing algorithms, and a logarithmic fitting function is suggested. Measurements of the camera response versus the angle of incidence reveal that the camera does not exhibit a cos(4) falloff on detector irradiance as one would expect, which is another consequence of the internal algorithms.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Intercomparison of Approaches to the Empirical Line Method for Vicarious Hyperspectral Reflectance Calibration
    Ortiz, Joseph D.
    Avouris, Dulcinea
    Schiller, Stephen
    Luvall, Jeffrey C.
    Lekki, John D.
    Tokars, Roger P.
    Anderson, Robert C.
    Shuchman, Robert
    Sayers, Michael
    Becker, Richard
    FRONTIERS IN MARINE SCIENCE, 2017, 4
  • [22] Pre-Launch Calibration of the Bidirectional Reflectance Distribution Function (BRDF) of Ultraviolet-Visible Hyperspectral Sensor Diffusers
    Mao, Jinghua
    Wang, Yongmei
    Shi, Entao
    Wang, Jinduo
    Yao, Shun
    Zhu, Jun
    APPLIED SCIENCES-BASEL, 2024, 14 (16):
  • [23] REFLECTANCE CALIBRATION SCHEME FOR AIRBORNE FRAME CAMERA IMAGES
    Beisl, U.
    XXII ISPRS CONGRESS, TECHNICAL COMMISSION VII, 2012, 39 (B7): : 1 - 5
  • [24] Assessment of VIIRS Radiometric Performance using Vicarious Calibration Sites
    Uprety, Sirish
    Cao, Changyong
    Blonski, Slawomir
    Wang, Wenhui
    EARTH OBSERVING SYSTEMS XIX, 2014, 9218
  • [25] Characterization and calibration of a high-resolution multispectral airborne digital camera
    Déliot, P
    Duffaut, J
    Lacan, A
    ICO20: REMOTE SENSING AND INFRARED DEVICES AND SYSTEMS, 2006, 6031
  • [26] Vicarious spaceborne polarimetric camera calibration using solar power stations
    Bertschy, Yannick
    Schechner, Yoav Y.
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING XV, 2022, 12112
  • [27] Vicarious Radiometric Calibration of the Ground-based Hyperspectral Camera Image
    Shin, Jung-Ii
    Maghsoudi, Yasser
    Kim, Sun-Hwa
    Kang, Sung-Jin
    Lee, Kyu-Sung
    KOREAN JOURNAL OF REMOTE SENSING, 2008, 24 (02) : 213 - 222
  • [28] Vicarious Radiometric Calibration of a Multispectral Camera on Board an Unmanned Aerial System
    Del Pozo, Susana
    Rodriguez-Gonzalvez, Pablo
    Hernandez-Lopez, David
    Felipe-Garcia, Beatriz
    REMOTE SENSING, 2014, 6 (03) : 1918 - 1937
  • [29] Calibration of illumination loss to measure luminance and chromaticity distribution by using digital camera
    Akimoto, Manabu
    Yamaguchi, Hideki
    Shinoda, Hiroyuki
    I-PERCEPTION, 2011, 2 (04): : 379 - 379
  • [30] NGST Phase Retrieval Camera design and calibration details
    Faust, JA
    Lowman, AE
    Redding, DC
    Basinger, SA
    Green, JJ
    Ohara, CM
    Shi, F
    IR SPACE TELESCOPES AND INSTRUMENTS, PTS 1 AND 2, 2003, 4850 : 398 - 406