A Stand-alone MATLAB Application for the Detection of Optic Disc and Macula

被引:0
|
作者
Ramasubramanian, B. [1 ]
Selvaperumal, S. [2 ]
机构
[1] Syed Ammal Engn Coll, Dept Elect & Commun Engn, Ramanathapuram, Tamil Nadu, India
[2] Syed Ammal Engn Coll, Dept Elect & Elect Engn, Ramanathapuram, Tamil Nadu, India
关键词
Bilateral filter; Diabetic Retinopathy; Glaucoma; Macula; Optic Disc; AUTOMATED SEGMENTATION; BLOOD-VESSELS; NERVE HEAD; IMAGES;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Glaucoma and Diabetic Retinopathy are the leading common cause of vision loss. Optic Disc and macula are the important landmark for the detection of these retinal pathology. Even though, the manual screening of Optic Disc and macula are available, they consume more time and have more human error. Therefore, there is a need of an automated application for the reliable and efficient localization of OD and macula. This paper presents a novel and fast stand-alone MATLAB application for the segmentation of these anatomical structures. This application uses colour K-means segmentation for locating macula and for detecting Optic Disc, bilateral filtering followed by Morphological operation is used. The application were evaluated on 135 glaucomatous images collected from local eye hospital and 200 diabetic retinopathy images from DIARETDB1 and DRIVE database. This stand-alone application consumes an average computation time of 13s for macula localization and 32s for OD segmentation with a success rate of 98%. Overall, the proposed application obtain an efficient result in the segmentation of both OD and macula, which in turn helps to detect glaucoma and Diabetic Retinopathy.
引用
收藏
页码:241 / 245
页数:5
相关论文
共 50 条
  • [31] MIMS is not a stand-alone resource
    Donohoo, Elizabeth A.
    MEDICAL JOURNAL OF AUSTRALIA, 2007, 186 (09) : 484 - 484
  • [32] Stand-alone and network capable pocket radiation detection system
    Aryaeinejad, R.
    Spencer, D. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (03): : 604 - 608
  • [33] An Improvized Fuel Cell System for Stand-Alone Mode Application
    Roy, Amit Kumar
    Biswal, Gyan Ranjan
    Padhy, Narayana Prasad
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [34] Precise Positioning using Stand-alone GPS for Maritime Application
    Park, Sul Gee
    Cho, Deuk Jae
    OCEANS, 2012 - YEOSU, 2012,
  • [35] Optic disc and macula detection in fundus images by means of template matching
    Garduno-Alvarado, Tzolkin
    Elena Martinez-Perez, M.
    Martinez-Castellanos, Maria A.
    Rodriguez-Quinones, Luvia
    Salinas-Longoria, Samantha M.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 134 - 137
  • [36] Combining algorithms for automatic detection of optic disc and macula in fundus images
    Qureshi, Rashid Jalal
    Kovacs, Laszlo
    Harangi, Balazs
    Nagy, Brigitta
    Peto, Tunde
    Hajdu, Andras
    COMPUTER VISION AND IMAGE UNDERSTANDING, 2012, 116 (01) : 138 - 145
  • [37] Simulation and Analysis of Stand-alone Photovoltaic System with Boost Converter using MATLAB/Simulink
    Mohammed, S. Sheik
    Devaraj, D.
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 814 - 821
  • [38] Java']Java Stand-Alone Application for Linear Control Systems Simulation
    Brito Palma, L.
    Costa Cruz, J.
    Sousa Gil, P.
    Vieira Coito, F.
    2014 11TH INTERNATIONAL CONFERENCE ON REMOTE ENGINEERING AND VIRTUAL INSTRUMENTATION (REV), 2014, : 361 - 369
  • [39] Compatibility and bundling of stand and No stand-alone use complements
    Vamosiu, Adriana
    INTERNATIONAL JOURNAL OF PRODUCTION ECONOMICS, 2018, 201 : 62 - 74
  • [40] PSOslope: A Stand-Alone Windows Application for Graphical Analysis of Slope Stability
    Chen, Walter
    Chen, Powen
    ADVANCES IN SWARM INTELLIGENCE, PT I, 2011, 6728 : 56 - 63