Utility of endoscopic anatomical optical coherence tomography in functional rhinoplasty

被引:4
|
作者
Balakrishnan, Santosh [1 ]
Bu, Ruofei [1 ]
Waters, Candace M. [2 ]
Brandon, Bryan M. [2 ]
Kimbell, Julia S. [2 ]
Stepp, Wesley H. [2 ]
Shockley, William W. [2 ]
Clark, J. Madison [2 ]
Oldenburg, Amy L. [1 ,3 ,4 ]
机构
[1] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27515 USA
[2] Univ N Carolina, Sch Med, Dept Otolaryngol Head & Neck Surg, Chapel Hill, NC 27515 USA
[3] Univ N Carolina, Dept Phys & Astron, Chapel Hill, NC 27515 USA
[4] Univ N Carolina, Biomed Res Imaging Ctr, Chapel Hill, NC 27515 USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; endoscopic OCT; nasal valve compromise; functional rhinoplasty; nasal valve surgery; INTERNAL NASAL VALVE; COMPUTED-TOMOGRAPHY; DIAGNOSIS;
D O I
10.1117/1.JBO.25.1.016001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Objective measurement of the nasal valve region is valuable for the assessment of functional rhinoplasty surgical outcomes. Anatomical optical coherence tomography (aOCT) is an imaging modality that may be used to obtain real-time, quantitative, and volumetric scans of the nasal airway. We aim to evaluate if volumetric aOCT imaging is useful for the examination of the nasal valve region before and after functional rhinoplasty procedures. aOCT scans of the nasal valves were performed on four cadaveric heads before and after spreader graft and butterfly graft procedures. The resulting aOCT images were compared against video endoscopy images, and the segmented volumes of the nasal airway obtained from aOCT scans were compared with computed tomography (CT) derived volumes acquired under the same conditions. The aOCT-derived volumes match the CT volumes closely, with a mean Dice similarity coefficient of 0.88 and a mean Hausdorff distance of 2.3 mm. Furthermore, the aOCT images were found to represent the shape of the nasal cavity accurately. Due to its ability to perform real-time, quantitative, and accurate evaluation of the nasal airway, aOCT imaging is a promising modality for the objective assessment of the nasal valves before and after functional rhinoplasty procedures. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Criteria for the diagnosis of dysplasia by endoscopic optical coherence tomography
    Pfau, PR
    Sivak, MV
    Chak, A
    Kinnard, M
    Wong, RCK
    Isenberg, GA
    Izatt, JA
    Rollins, A
    Westphal, V
    GASTROINTESTINAL ENDOSCOPY, 2003, 58 (02) : 196 - 202
  • [32] Endoscopic optical coherence tomography and angiography for gastroenterology applications
    Lee, Hsiang-Chieh
    Liang, Kaicheng
    Ahsen, Osman O.
    Wang, Zhao
    Figueiredo, Marisa
    Potsaid, Benjamin
    Jayaraman, Vijaysekhar
    Huang, Qin
    Mashimo, Hiroshi
    Fujimoto, James G.
    BIOMEDICAL IMAGING AND SENSING CONFERENCE, 2018, 10711
  • [33] Endoscopic optical coherence tomography for imaging the tympanic membrane
    Burkhardt, Anke
    Walther, Julia
    Cimalla, Peter
    Bornitz, Matthias
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES V, 2011, 8091
  • [34] MEMS-Based Endoscopic Optical Coherence Tomography
    Sun, Jingjing
    Xie, Huikai
    INTERNATIONAL JOURNAL OF OPTICS, 2011, 2011
  • [35] Endoscopic optical coherence tomography at the middle ear diagnostics
    Schindler, Martin
    Kirsten, Lars
    Morgenstern, Joseph
    Golde, Jonas
    Walter, Julia
    Kemper, Max
    Bornitz, Matthias
    Neudert, Marcus
    Zahnert, Thomas
    Koch, Edmund
    CLINICAL AND PRECLINICAL OPTICAL DIAGNOSTICS II, 2019, 11073
  • [36] Endoscopic optical coherence tomography based on a microelectromechanical mirror
    Pan, YT
    Xie, HK
    Fedder, GK
    OPTICS LETTERS, 2001, 26 (24) : 1966 - 1968
  • [37] Advances in Endoscopic Optical Coherence Tomography Catheter Designs
    Adams, David C.
    Wang, Yan
    Hariri, Lida P.
    Suter, Melissa J.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2016, 22 (03) : 210 - 221
  • [38] Piezoelectric scanning mirrors for endoscopic optical coherence tomography
    Gilchrist, Kristin H.
    McNabb, Ryan P.
    Izatt, Joseph A.
    Grego, Sonia
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (09)
  • [39] Ultrahigh speed endoscopic optical coherence tomography for gastroenterology
    Tsai, Tsung-Han
    Lee, Hsiang-Chieh
    Ahsen, Osman O.
    Liang, Kaicheng
    Giacomelli, Michael G.
    Potsaid, Benjamin M.
    Tao, Yuankai K.
    Jayaraman, Vijaysekhar
    Figueiredo, Marisa
    Huang, Qin
    Cable, Alex E.
    Fujimoto, James
    Mashimo, Hiroshi
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (12): : 4387 - 4404
  • [40] Methods and application areas of endoscopic optical coherence tomography
    Yaqoob, Zahid
    Wu, Jigang
    McDowell, Emily J.
    Heng, Xin
    Yang, Changhuei
    JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (06)