Theoretical analysis of R1234ze(E), R152a, and R1234ze(E)/R152a mixtures as replacements of R134a in vapor compression system

被引:28
|
作者
Meng, Zhaofeng [1 ]
Zhang, Hua [1 ]
Qiu, Jinyou [1 ]
Lei, Mingjing [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Energy & Power Engn, 516 Jungong Rd, Shanghai 200093, Peoples R China
来源
ADVANCES IN MECHANICAL ENGINEERING | 2016年 / 8卷 / 11期
基金
中国国家自然科学基金;
关键词
R1234ze(E); R152a; R134a; vapor compression system; mixed refrigerants; ENERGY PERFORMANCE EVALUATION; LOW-GWP REFRIGERANTS; DOMESTIC REFRIGERATOR; EXERGY ANALYSIS; DROP; ALTERNATIVES; TEMPERATURE; R1234YF; R450A;
D O I
10.1177/1687814016676945
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this article, R1234ze(E), R152a, and three mixtures M1, M2, and M3 composed of R152a and R1234ze(E) (in the ratio of 60: 40, 50: 50, and 40: 60, by mass, respectively) as drop-in replacements of R134a in vapor compression system were theoretically analyzed. The performance of the vapor compression system was compared in terms of compressor discharge temperature, volumetric cooling capacity, cooling capacity, compressor power consumption, and coefficient of performance. The results showed that R152a had better coefficient of performance as well as nearly equal volumetric cooling capacity and cooling capacity compared to R134a; however, flammable R152a running with high compressor discharge temperature was restricted. Cooling capacity of R1234ze(E) was far lower than that of R134a. M2 was selected as the best alternative for R134a. Volumetric cooling capacity of M2 and R134a was similar so that M2 can be used in R134a vapor compressor system without modifying compressor. Coefficient of performance of M2 was higher than that of R134a by about 3% with 7% lower cooling capacity and 10% lower compressor power consumption. Compressor discharge temperature of M2 was higher than that of R134a by about 2 degrees C-5 degrees C. It was concluded that M2 can primely be an energy conservation and environmental protection alternative to R134a in vapor compression system.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] Analysis the characteristics of R1234yf, R1234ze, R134a on reefer container
    Ding, Defeng
    Zhu, Zhenxiang
    Chen, Wu
    Liu, Shijie
    Zheng, Chaoyu
    2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING (ICAESEE 2019), 2020, 446
  • [22] Experimental study of an R1234ze(E)/R134a mixture (R450A) as R134a replacement
    Mota-Babiloni, Adrian
    Navarro-Esbri, Joaquin
    Barragan-Cervera, Angel
    Moles, Francisco
    Peris, Bernardo
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 51 : 52 - 58
  • [23] Energy and exergy investigation of R1234ze as R134a replacement in vapor compression chillers
    Ben Jemaa, Radhouane
    Mansouri, Rami
    Boukholda, Ismail
    Bellagi, Ahmed
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (17) : 12877 - 12887
  • [24] Investigation of pρTx properties for R1234ze(E)+R134a mixtures in the gas phase
    Zhang, Haiyang
    Dong, Xueqiang
    Zhong, Quan
    Li, Huiya
    Gong, Maoqiong
    Shen, Jun
    Wu, Jianfeng
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 73 : 144 - 153
  • [25] The Effect of Heat Exchanger Tube Structure on the Condensation Heat Transfer of R1234ze(E)/R152a Inside Smooth Tubes
    Dai, Yuande
    Tang, Qingqing
    Xu, Chaoping
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2024, 16 (01)
  • [26] Surface tension and liquid viscosity measurement for binary mixtures of R134a with R1234yf and R1234ze(E)
    Bi, Shengshan
    Cui, Junwei
    Zhao, Guanjia
    Wu, Jiangtao
    FLUID PHASE EQUILIBRIA, 2016, 414 : 60 - 64
  • [27] Liquid Viscosity Measurements for the Binary and Ternary Refrigerant Mixtures of R134a, R1234ze(E), and R1234yf
    Liang, Ximei
    Sun, Qingyu
    Meng, Xianyang
    Wu, Jiangtao
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2022, 67 (08): : 1872 - 1881
  • [28] R1234yf and R1234ze(E) as environmentally friendly replacements of R134a: Assessing flow boiling on an experimental basis
    Longo, Giovanni A.
    Mancin, Simone
    Righetti, Giulia
    Zilio, Claudio
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 108 : 336 - 346
  • [29] Evaporation of R1234yf, R1234ze(E) and R1234ze(Z) on Cu surface: A molecular dynamics study
    Deng, Xinxin
    Xiao, Yitian
    Li, Qibin
    He, Chao
    Wang, Shukun
    JOURNAL OF MOLECULAR LIQUIDS, 2021, 344
  • [30] Exergy Analysis of a Solar Vapor Compression Refrigeration System Using R1234ze(E) as an Environmentally Friendly Replacement of R134a
    Triki, Zakaria
    Selloum, Ahmed
    Chiba, Younes
    Tahraoui, Hichem
    Mansour, Dorsaf
    Amrane, Abdeltif
    Zamouche, Meriem
    Kebir, Mohammed
    Zhang, Jie
    FRONTIERS IN HEAT AND MASS TRANSFER, 2024, 22 : 1107 - 1128