Accuracy of guideline recommendations for two-dimensional quantification of the right ventricle by echocardiography

被引:184
|
作者
Lai, Wyman W. [1 ,2 ]
Gauvreau, Kimberlee [1 ,2 ]
Rivera, Ernesto S. [1 ,2 ]
Saleeb, Susan [1 ,2 ]
Powell, Andrew J. [1 ,2 ]
Geva, Tal [1 ,2 ]
机构
[1] Childrens Hosp, Dept Cardiol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Dept Pediat, Boston, MA 02115 USA
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2008年 / 24卷 / 07期
关键词
echocardiography; magnetic resonance imaging; right ventricle;
D O I
10.1007/s10554-008-9314-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The accuracy of the guidelines of the American Society of Echocardiography (ASE) for the two-dimensional (2D) quantitative assessment of right ventricular (RV) size and function has not been evaluated against MRI-derived RV volumes in patients with congenital heart disease and RV volume overload. Methods Three groups of patients were studied: a normal RV group (Group I, n = 31), a repaired tetralogy of Fallot group (Group II, n = 33), and an unrepaired atrial septal defect and/or partially anomalous pulmonary venous connection group (Group III, n = 23). Recommended 2D linear and cross-sectional area measurements were made on clinical echocardiographic and MRI studies performed less than 6 months apart. Results Most 2D RV parameters were smaller by echocardiography versus MRI. There was weak correlation between 2D RV measurements by echocardiography and MRI-derived RV volumes (Group I: r = 0.15-0.54, Group II: r = 0.33-0.61, Group III: r = 0.32-0.85), and only modest improvement when the same 2D measurements were performed by MRI (Group I: r = 0.37-0.61, Group II: r = 0.44-0.69, Group III: r = 0.28-0.74). The difference between 2D RV measurements by echocardiography and MRI-derived RV volumes was more pronounced in the RV volume overload groups. Conclusions The correlation between currently recommended 2D RV measurements by echocardiography and MRI-derived RV volumes was weak, and improved only modestly when MRI was used to make the same 2D measurements. Moreover, 2D echocardiographic assessment of the RV appears to be less accurate in patients with congenital heart disease and a dilated RV.
引用
收藏
页码:691 / 698
页数:8
相关论文
共 50 条
  • [21] Three-dimensional visual guidance improves the accuracy of calculating right ventricular volume with two-dimensional echocardiography
    Dorosz, JL
    Bolson, EL
    Waiss, MS
    Sheehan, FH
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2003, 16 (06) : 675 - 681
  • [22] Assessment of right ventricular function by two-dimensional strain in patients with left ventricular dysfunction and normal right ventricle by standard echocardiography
    Dinis Valbom Mesquita, D.
    Caetano, F.
    Sousa, C.
    Almeida, H.
    Pinto, A.
    Santos, L.
    Tavares, J.
    EUROPEAN JOURNAL OF HEART FAILURE, 2015, 17 : 229 - 229
  • [23] Right ventricular imaging by two-dimensional and three-dimensional echocardiography
    Mangion, Judy R.
    CURRENT OPINION IN CARDIOLOGY, 2010, 25 (05) : 423 - 429
  • [24] Reference ranges and determinants of right ventricle outflow tract acceleration time in healthy adults by two-dimensional echocardiography
    Alberto M. Marra
    Nicola Benjamin
    Francesco Ferrara
    Olga Vriz
    Michele D’Alto
    Antonello D’Andrea
    Anna Agnese Stanziola
    Luna Gargani
    Antonio Cittadini
    Ekkehard Grünig
    Eduardo Bossone
    The International Journal of Cardiovascular Imaging, 2017, 33 : 219 - 226
  • [25] DIFFERENTIATION OF VARIOUS FORMS OF SINGLE VENTRICLE USING TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    RUPPRATH, G
    VOGT, J
    BEUREN, AJ
    ZEITSCHRIFT FUR KARDIOLOGIE, 1981, 70 (04): : 326 - 326
  • [26] Reference ranges and determinants of right ventricle outflow tract acceleration time in healthy adults by two-dimensional echocardiography
    Marra, Alberto M.
    Benjamin, Nicola
    Ferrara, Francesco
    Vriz, Olga
    D'Alto, Michele
    D'Andrea, Antonello
    Stanziola, Anna Agnese
    Gargani, Luna
    Cittadini, Antonio
    Gruenig, Ekkehard
    Bossone, Eduardo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (02): : 219 - 226
  • [27] THE TWO-DIMENSIONAL ECHOCARDIOGRAPHIC FINDINGS IN DOUBLE OUTLET RIGHT VENTRICLE
    DISESSA, TG
    HAGAN, AD
    TI, CC
    POPE, C
    SAMTOY, LM
    FRIEDMAN, WF
    PEDIATRIC CARDIOLOGY, 1980, 1 (02) : 175 - 175
  • [28] Reference values and determinants of right ventricle outflow tract acceleration time in healthy adults by two-dimensional echocardiography
    Marra, A. M.
    Benjamin, N.
    Ferrara, F.
    Vritz, O.
    Gargani, L.
    D'Alto, M.
    Stanziola, A. A.
    Carannante, L.
    Cittadini, A.
    Gruenig, E.
    Bossone, E.
    EUROPEAN HEART JOURNAL, 2016, 37 : 859 - 859
  • [29] QUANTIFICATION OF LEFT-VENTRICULAR FUNCTION BY TWO-DIMENSIONAL ECHOCARDIOGRAPHY
    ERBEL, R
    SCHWEIZER, P
    MEYER, J
    KREBS, W
    EFFERT, S
    ULTRASCHALL IN DER MEDIZIN, 1983, 4 (04): : 228 - 236
  • [30] Software for quantification of pericardial effusion volume by two-dimensional echocardiography
    Lucariello, RJ
    Sun, Y
    Paturu, P
    Chiaramida, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 495A - 495A