Small displacement measurement based on surface plasmon resonance and heterodyne interferometry

被引:0
|
作者
Chiu, MH [1 ]
Shih, BY [1 ]
Shih, CH [1 ]
Kao, LC [1 ]
Shyu, LH [1 ]
机构
[1] Natl Formosa Univ, Dept Electroopt Engn, 64 Wunhua Rd, Huwei Yunlin 632, Taiwan
关键词
surface plasmon resonance (SPR); heterodyne interferometry (HI);
D O I
10.1117/12.637737
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new method for small displacement measurement based on surface plasmon resonance and heterodyne interferometry is presented. A heterodyne light is focused on a mirror and reflected from it, and then it is incident on a prism which was coated with a thin gold film. When the mirror or the objective lens has a small displacement, the light will be converging or diverging into the prism, and the phase variation between two parts of the test beam under the condition of surface plasmon resonance (SPR) can be measured by using a two-segment photodiode and a lock-in amplifier. This phase difference between two parts of the test beam is proportional to the departure of the mirror from the focal plane, so the displacement can be obtained in real-time. It has some merits, such as, simple, stable, very high sensitivity and resolution. And its resolution is better than 1 nm.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry
    Wu, CM
    Jian, ZC
    Joe, SF
    Chang, LB
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2003, 92 (1-2): : 133 - 136
  • [12] Measuring physical parameters with surface plasmon resonance heterodyne interferometry
    Chen, Kun-Huang
    Lin, Jiun-You
    Chen, Jing-Heng
    [J]. OPTIK, 2009, 120 (01): : 29 - 34
  • [13] High-sensitivity small-angle sensor based on surface plasmon resonance technology and heterodyne interferometry
    Wang, Shinn-Fwu
    Chiu, Ming-Hung
    Lai, Chih-Wen
    Chang, Rong-Seng
    [J]. APPLIED OPTICS, 2006, 45 (26) : 6702 - 6707
  • [14] Surface plasmon resonance heterodyne interferometry from measuring physical parameters
    Su, DC
    Chen, JH
    Chen, KH
    Lin, JY
    [J]. OPTICAL METROLOGY IN PRODUCTION ENGINEERING, 2004, 5457 : 566 - 573
  • [15] Improved Small-Angle Sensor Based on Total-Internal Reflection and Surface Plasmon Resonance in Heterodyne Interferometry
    Wang, Shinn-Fwu
    Tsai, Hung-Shing
    Chu, Yi
    Wei, Jeng-Hua
    Chau, Yuan-Fong
    Liu, An-Li
    Kao, Fu-Hsi
    [J]. SENSORS AND MATERIALS, 2013, 25 (06) : 417 - 422
  • [16] Measurement of refractive index variation of liquids by surface plasmon resonance and wavelength-modulated heterodyne interferometry
    Lee, Ju-Yi
    Tsai, Shin-Kai
    [J]. OPTICS COMMUNICATIONS, 2011, 284 (04) : 925 - 929
  • [17] D-type fiber biosensor based on surface-plasmon resonance technology and heterodyne interferometry
    Chiu, MH
    Wang, SF
    Chang, RS
    [J]. OPTICS LETTERS, 2005, 30 (03) : 233 - 235
  • [18] Heterodyne grating interferometry based on sinusoidal phase modulation for displacement measurement
    Lee, Ju-Yi
    Hsieh, Hung-Lin
    Lin, Zhi Ying
    [J]. OPTICAL MEASUREMENT SYSTEMS FOR INDUSTRIAL INSPECTION X, 2017, 10329
  • [19] Enhanced sensitivity to surface plasmon resonance phase in wavelength-modulated heterodyne interferometry
    Lee, Ju-Yi
    Mai, Li-Wei
    Hsu, Cheng-Chih
    Sung, Yuan-Yuan
    [J]. OPTICS COMMUNICATIONS, 2013, 289 : 28 - 32
  • [20] Development of an Angular Displacement Measurement by Birefringence Heterodyne Interferometry
    Chen, Lin-Yu
    Lee, Ju-Yi
    Chang, Hung-Sheng
    Yang, Yang
    [J]. SMART SCIENCE, 2015, 3 (04) : 188 - 192