Three-Dimensional Finite Element Analysis of Maxillary Sinus Floor Augmentation with Optimal Positioning of a Bone Graft Block

被引:5
|
作者
Schuller-Goetzburg, Peter [1 ]
Forte, Thomas [1 ,3 ]
Pomwenger, Werner [2 ]
Petutschnigg, Alexander [3 ]
Watzinger, Franz [4 ]
Entacher, Karl [2 ]
机构
[1] Paracelsus Med Univ, Biomech & Biomat Res, Prosthet, Strubergasse 21, A-5020 Salzburg, Austria
[2] Salzburg Univ Appl Sci, Dept Informat Technol & Syst Management, Urstein Sud 1, A-5412 Puch, Austria
[3] Salzburg Univ Appl Sci, Dept Forest Prod Technol & Wood Construct, Markt 136a, A-5431 Kuchl, Austria
[4] Landesklinikum St Polten Lilienfeld, Dept Maxillofacial Surg, Probst Fuhrer Str 4, A-3100 St Polten, Austria
来源
SYMMETRY-BASEL | 2018年 / 10卷 / 02期
基金
奥地利科学基金会;
关键词
sinus lift; bone grafting; finite element analysis; 3D modeling; dental implant; STRESS-DISTRIBUTION; FORCE MEASUREMENTS; POSTERIOR MAXILLA; CORTICAL BONE; IMPLANT; LAW; INTERFACE; REGION;
D O I
10.3390/sym10020033
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: the aim of the computational 3D-finite element study is to evaluate the influence of an augmented sinus lift with additional inserted bone grafting. The bone graft block stabilizes the implant in conjunction with conventional bone augmentation. Two finite element models were applied: the real geometry based bone models and the simplified geometry models. The bone graft block was placed in three different positions. The implants were loaded first with an axial force and then with forces simulating laterotrusion and protrusion. This study examines whether the calculated stress behavior is symmetrical for both models. Having established a symmetry between the primary axis, the laterotrusion and protrusion behavior reduces calculation efforts, by simplifying the model. Material and Methods: a simplified U-shaped 3D-finite element model of the molar region of the upper jaw and a more complex anatomical model of the left maxilla with less cortical bone were created. The bone graft block was placed in the maxillary sinus. Then the von Mises stress distribution was calculated and analyzed at three block positions: at contact with the sinus floor, in the middle of the implant helix and in the upper third of the implant. The two finite element models were then compared to simplify the modelling. Results: the position of the bone graft block significantly influences the magnitude of stress distribution. A bone graft block positioned in the upper third or middle of the implant reduces the quantity of stress compared to the reference model without a bone graft block. The low bone graft block position is clearly associated with lower stress distribution in compact bone. We registered no significant differences in stress in compact bone with regard to laterotrusion or protrusion. Conclusions: maximum values of von Mises stresses in compact bone can be reduced significantly by using a bone graft block. The reduction of stress is nearly the same for positions in the upper third and the middle of the implant. It is much more pronounced when the bone graft block is in the lower third of the implant near the sinus floor, which appeared to be the best position in the present study.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Evaluation of Three-Dimensional Volumetric Changes After Sinus Floor Augmentation with Mineralized Cortical Bone Allograft
    Berberi A.
    Bouserhal L.
    Nader N.
    Assaf R.B.
    Nassif N.B.
    Bouserhal J.
    Salameh Z.
    Journal of Maxillofacial and Oral Surgery, 2015, 14 (3) : 624 - 629
  • [22] Three-dimensional volumetric measurements and analysis of the maxillary sinus
    Deeb, Robert
    Malani, Preeti N.
    Gil, Baljinder
    Jafari-Khouzani, Kourosh
    Soltanian-Zadeh, Hamid
    Patel, Suresh
    Zacharek, Mark A.
    AMERICAN JOURNAL OF RHINOLOGY & ALLERGY, 2011, 25 (03) : 152 - 156
  • [23] STRAIN ANALYSIS OF MAXILLARY COMPLETE DENTURE WITH THREE-DIMENSIONAL FINITE ELEMENT METHOD
    Cheng, Yi Y.
    Cheung, Wai L.
    Chow, Tak W.
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (05): : 309 - 318
  • [24] Three-dimensional finite element analysis of maxillary protraction with labiolingual arches and implants
    Liu, Chang
    Zhu, Xianchun
    Zhang, Xing
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 148 (03) : 466 - 478
  • [25] Two Composite Bone Graft Substitutes for Maxillary Sinus Floor Augmentation: Histological, Histomorphometric, and Radiographic Analyses
    Ahmet, Safak
    Gultekin, Bahattin Alper
    Karabuda, Zihni Cuneyt
    Olgac, Vakur
    IMPLANT DENTISTRY, 2016, 25 (03) : 313 - 321
  • [26] The Effect of Bovine Bone Graft With or Without Platelet-Rich Plasma on Maxillary Sinus Floor Augmentation
    Cabbar, Fatih
    Guler, Nurhan
    Kurkcu, Mehmet
    Iseri, Ufuk
    Sencift, Kemal
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (10) : 2537 - 2547
  • [27] Association between implant apex and sinus floor in posterior maxilla dental implantation: A three-dimensional finite element analysis
    Yan, Xu
    Zhang, Xinwen
    Chi, Weichao
    Ai, Hongjun
    Wu, Lin
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 9 (03) : 868 - 876
  • [28] Three-dimensional finite element analysis of stress in the periodontal ligament of the maxillary first molar with simulated bone loss
    Jeon, PD
    Turley, PK
    Ting, K
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2001, 119 (05) : 498 - 504
  • [29] Three-Dimensional Evaluation of Implant Positioning in the Maxillary Sinus Septum: A Retrospective Study
    Dragan, Eliza
    Guillaume, Odri A.
    Haba, Danisia
    Olszewski, Raphael
    MEDICAL SCIENCE MONITOR, 2015, 21
  • [30] Three-dimensional finite element modeling of composite floor beams
    Tahmasebinia, F.
    Ranzi, G.
    INCORPORATING SUSTAINABLE PRACTICE IN MECHANICS OF STRUCTURES AND MATERIALS, 2011, : 71 - 75