Development and Validation of RP-HPLC Method for Simultaneous Estimation of Atorvastatin Calcium and Fenofibrate in Tablet Dosage Forms

被引:0
|
作者
Jain, N. [1 ]
Raghuwanshi, R. [1 ]
Jain, Deepti [1 ]
机构
[1] Rajiv Gandhi Proudhyogiki Vishwavidhyalaya, Sch Pharmaceut Sci, Bhopal 462036, India
关键词
RP-HPLC; simultaneous determination; atorvastatin; calcium; fenofibrate; development and validation;
D O I
暂无
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
A reverse phase high performance liquid chromatographic method was developed for the simultaneous estimation of atorvastatin calcium and fenofibrate in tablet formulation. The separation was achieved by Luna C18 column and methanol: acetate buffer pH 3.7 ( 82: 18 v/v) as mobile phase, at a flow rate of 1.5 ml/min. Detection was carried out at 248 nm. Retention time of atorvastatin calcium and fenofibrate was found to be 3.02+0.1 and 9.05+0.2 min, respectively. The method has been validated for linearity, accuracy and precision. Linearity for atorvastatin calcium and Fenofibrate were in the range of 1-5 mu g/ml and 16-80 mu g/ml, respectively. The mean recoveries obtained for Atorvastatin calcium and fenofibrate were 101.76% and 100.06%, respectively. Developed method was found to be accurate, precise, selective and rapid for simultaneous estimation of atorvastatin calcium and fenofibrate in tablets.