Contrast sensitivity after refractive lens exchange with a multifocal diffractive aspheric intraocular lens

被引:3
|
作者
Ferrer-Blasco, Teresa [1 ]
Garcia-Lazaro, Santiago [1 ]
Albarran-Diego, Cesar [1 ]
Perez-Vives, Cari [1 ]
Montes-Mico, Robert [1 ]
机构
[1] Univ Valencia, Dept Opt, E-46100 Burjassot, Valencia, Spain
关键词
Lens implantation; intraocular; Lens cristalline/surgery; Myopia/surgery; Hyperopia/physiopathology; Phacoemulsification; Visual acuity; VISUAL FUNCTION; IMPLANTATION; DISTANCE; OUTCOMES; QUALITY; DISCRIMINATION; PERFORMANCE; CLEAR; EYES;
D O I
10.1590/S0004-27492013000200002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate distance and near contrast sensitivity (CS) under photopic and mesopic conditions before and after refractive lens exchange (RLE) and implantation of the aspheric AcrySof (R) ReSTOR (R) (SN6AD3 model) intraocular lens (IOL). Methods: Seventy-four eyes of 37 patients after RLE underwent bilateral implantation with the aspheric AcrySof ReSTOR IOL. The patient sample was divided into myopic and hyperopic groups. Monocular uncorrected visual acuity at distance and near (UCVA and UCNVA, respectively) and monocular best corrected visual acuity at distance and near (BCVA and BCNVA, respectively) were measured before and 6 months postoperatively. Monocular CS function was measured at three different luminance levels (85, 5 and 2.5 cd/m(2)) before and after RLE. Post-implantation results at 6 months were compared with those found before surgery. Results: Our results revealed that patients in both groups obtained good UCVA and BCVA after RLE at distance and near vision in relation to pre-surgery values. No statistically significant differences were found between the values of CS pre and post-RLE at distance and near, at any lighting condition and spatial frequency (p>0.002). Conclusions: Refractive lens exchange with aspheric AcrySof ReSTOR IOL in myopic and hyperopic population provided good visual function and yield good distance and near CS under photopic and mesopic conditions.
引用
下载
收藏
页码:63 / 68
页数:6
相关论文
共 50 条
  • [1] Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (03) : 192 - 196
  • [2] Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Cervino, Alejandro
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (12): : 2043 - 2048
  • [3] Clinical evaluation of a multifocal aspheric diffractive intraocular lens
    Schmickler, Stefanie
    Palomino Bautista, Carlos
    Goes, Frank
    Shah, Sunil
    Wolffsohn, James S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (12) : 1560 - 1564
  • [4] Refractive lens exchange with the diffractive multifocal Tecnis ZM900 intraocular lens
    Goes, Frank Joseph
    JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (03) : 243 - 250
  • [5] Visual performance after implantation of an aspheric multifocal diffractive intraocular lens
    Akaishi, Leonardo
    Messias, Camila Brito
    de Moraes Tzelikis, Patrick Frensel
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2010, 69 (04) : 230 - 235
  • [6] Refractive outcomes after multifocal intraocular lens exchange
    Kim, Eric J.
    Sajjad, Ahmar
    de Oca, Ildamaris Montes
    Koch, Douglas D.
    Wang, Li
    Weikert, Mitchell P.
    Al-Mohtaseb, Zaina N.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06): : 761 - 766
  • [7] Refractive lens exchange with the Array multifocal intraocular lens
    Packer, M
    Fine, IH
    Hoffman, RS
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (03): : 421 - 424
  • [8] Refractive lens exchange with an array multifocal intraocular lens
    Dick, HB
    Gross, S
    Tehrani, M
    Eisenmann, D
    Pfeiffer, N
    JOURNAL OF REFRACTIVE SURGERY, 2002, 18 (05) : 509 - 518
  • [9] CONTRAST SENSITIVITY AND GLARE IN PATIENTS WITH A DIFFRACTIVE MULTIFOCAL INTRAOCULAR-LENS
    WINTHERNIELSEN, A
    CORYDON, L
    OLSEN, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (02): : 254 - 257
  • [10] Visual Outcomes and Patient Satisfaction after Refractive Lens Exchange with a Single-Piece Diffractive Multifocal Intraocular Lens
    Chang, John S. M.
    Ng, Jack C. M.
    Chan, Vincent K. C.
    Law, Antony K. P.
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014