Highly sensitive and selective lateral flow immunoassay based on magnetic nanoparticles for quantitative detection of carcinoembryonic antigen

被引:60
|
作者
Liu, Fangming [1 ,2 ]
Zhang, Honglian [2 ]
Wu, Zhenhua [2 ]
Dong, Haidao [2 ,4 ]
Zhou, Lin [2 ]
Yang, Dawei [3 ]
Ge, Yuqing [2 ]
Jia, Chunping [2 ]
Liu, Huiying [4 ]
Jin, Qinghui [2 ]
Zhao, Jianlong [2 ]
Zhang, Qiqing [1 ]
Mao, Hongju [2 ]
机构
[1] Fuzhou Univ, Inst Biomed & Pharmaceut Technol, 523 Gongye Rd, Fuzhou 350002, Fujian Province, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Dept Pulm Med, Shanghai 200032, Peoples R China
[4] Dalian Med Univ, Sch Stomatol, Dept Oral & Maxillofacial, Dalian 116023, Peoples R China
基金
美国国家科学基金会;
关键词
Lateral-flow immunoassay; Magnetic nanoparticles; Carcinoembryonic antigen; Diagnosis; GOLD NANOPARTICLES; TEST STRIP; CANCER; CYFRA21-1;
D O I
10.1016/j.talanta.2016.08.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carcinoembryonic antigen (CEA) is an important biomarker in cancer diagnosis. Here, we present an efficient, selective lateral-flow immunoassay (LFIA) based on magnetic nanoparticles (MNPs) for in situ sensitive and accurate point-of-care detection of CEA. Signal amplification mechanism involved linking of detection MNPs with signal MNPs through biotin-modified single-stranded DNA (ssDNA) and streptavidin. To verify the effectiveness of this modified LFIA system, the sensitivity and specificity were evaluated. Sensitivity evaluation showed a broad detection range of 0.25-1000 ng/ml for CEA protein by the modified LFIA, and the limit of detection (LOD) of the modified LFIA was 0.25 ng/ml, thus producing significant increase in detection threshold compared with the traditional LFIA. The modified LFIA could selectively recognize CEA in presence of several interfering proteins. In addition, this newly developed assay was applied for quantitative detection of CEA in human serum specimens collected from 10 randomly selected patients. The modified LFIA system detected minimum 0.27 ng/ml of CEA concentration in serum samples. The results were consistent with the clinical data obtained using commercial electrochemiluminescence immunoassay (ECLIA) (p < 0.01). In conclusion, the MNPs based LFIA system not only demonstrated enhanced signal to noise ratio, it also detected CEA with higher sensitivity and selectivity, and thus has great potential to be commercially applied as a sensitive tumor marker filtration system. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [31] Highly Sensitive Chemiluminescence-Based Lateral Flow Immunoassay for Cardiac Troponin I Detection in Human Serum
    Han, Gyeo-Re
    Kim, Min-Gon
    SENSORS, 2020, 20 (09)
  • [32] Flower-shaped magnetic fluorescent nanoparticles based lateral flow biosensor for highly sensitive detection of cardiac troponin I
    Liu, Guan
    Chen, Mingrui
    Wang, Jiulin
    Cui, Xinyuan
    Wang, Kan
    Yang, Ziyang
    Gao, Ang
    Zhang, Amin
    Zhang, Qian
    Shen, Yulan
    Gao, Guo
    Cui, Daxiang
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 414
  • [33] A sensitive detection method of carcinoembryonic antigen based on dsDNA-templated copper nanoparticles
    Chen, Mingjian
    Khusbu, Farjana Yeasmin
    Ma, Changbei
    Wu, Kefeng
    Zhao, Han
    Chen, Hanchun
    Wang, Kemin
    NEW JOURNAL OF CHEMISTRY, 2018, 42 (16) : 13702 - 13707
  • [34] Lateral flow immunoassay based on gold nanoparticles for rapid and sensitive detection of zoxamide in grape, tomato and cucumber samples
    Cheng, Yuan
    Wu, Aihong
    Guo, Lingling
    Sun, Maozhong
    Gao, Rui
    Kuang, Hua
    Xu, Chuanlai
    Xu, Liguang
    FOOD CHEMISTRY, 2023, 426
  • [35] An Inexpensive, Fast and Sensitive Quantitative Lateral Flow Magneto-Immunoassay for Total Prostate Specific Antigen
    Barnett, Jacqueline M.
    Wraith, Patrick
    Kiely, Janice
    Persad, Raj
    Hurley, Katrina
    Hawkins, Peter
    Luxton, Richard
    BIOSENSORS-BASEL, 2014, 4 (03): : 204 - 220
  • [36] Isoniazide modified Ag nanoparticles triggered photothermal immunoassay for carcinoembryonic antigen detection
    Xiang, Jiawang
    Zhang, Bing
    Shi, Yani
    Wen, Yanfei
    Yuan, Yuan
    Lin, Jianying
    Zhao, Zhihuan
    Li, Jing
    Cheng, Yan
    ANALYTICAL BIOCHEMISTRY, 2023, 683
  • [37] Immunoassay for Carcinoembryonic Antigen Based on Fluorescence Induced by Laser and Labeled with Nanoparticles
    Zhang Xiaoming
    Zhang Zhujun
    Xue Pan
    ACTA CHIMICA SINICA, 2011, 69 (02) : 199 - 203
  • [38] DEVELOPMENT OF A RAPID QUANTITATIVE DETECTION OF NT-PROBNP BASED ON SUPERPARAMAGNETIC NANOPARTICLES AS LABELS IN THE LATERAL FLOW IMMUNOASSAY
    Wang Yanyan
    Wei Meng
    Li Jingbo
    Zhu Wei
    Xu Quanfu
    Gu Shuiming
    HEART, 2010, 96 : A210 - A211
  • [39] Rapid and sensitive lateral flow immunoassay for influenza antigen using fluorescently-doped silica nanoparticles
    Bamrungsap, Suwussa
    Apiwat, Chayachon
    Chantima, Warangkana
    Dharakul, Tararaj
    Wiriyachaiporn, Natpapas
    MICROCHIMICA ACTA, 2014, 181 (1-2) : 223 - 230
  • [40] Rapid and sensitive lateral flow immunoassay for influenza antigen using fluorescently-doped silica nanoparticles
    Suwussa Bamrungsap
    Chayachon Apiwat
    Warangkana Chantima
    Tararaj Dharakul
    Natpapas Wiriyachaiporn
    Microchimica Acta, 2014, 181 : 223 - 230