Highly sensitive and selective lateral flow immunoassay based on magnetic nanoparticles for quantitative detection of carcinoembryonic antigen

被引:60
|
作者
Liu, Fangming [1 ,2 ]
Zhang, Honglian [2 ]
Wu, Zhenhua [2 ]
Dong, Haidao [2 ,4 ]
Zhou, Lin [2 ]
Yang, Dawei [3 ]
Ge, Yuqing [2 ]
Jia, Chunping [2 ]
Liu, Huiying [4 ]
Jin, Qinghui [2 ]
Zhao, Jianlong [2 ]
Zhang, Qiqing [1 ]
Mao, Hongju [2 ]
机构
[1] Fuzhou Univ, Inst Biomed & Pharmaceut Technol, 523 Gongye Rd, Fuzhou 350002, Fujian Province, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Dept Pulm Med, Shanghai 200032, Peoples R China
[4] Dalian Med Univ, Sch Stomatol, Dept Oral & Maxillofacial, Dalian 116023, Peoples R China
基金
美国国家科学基金会;
关键词
Lateral-flow immunoassay; Magnetic nanoparticles; Carcinoembryonic antigen; Diagnosis; GOLD NANOPARTICLES; TEST STRIP; CANCER; CYFRA21-1;
D O I
10.1016/j.talanta.2016.08.048
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Carcinoembryonic antigen (CEA) is an important biomarker in cancer diagnosis. Here, we present an efficient, selective lateral-flow immunoassay (LFIA) based on magnetic nanoparticles (MNPs) for in situ sensitive and accurate point-of-care detection of CEA. Signal amplification mechanism involved linking of detection MNPs with signal MNPs through biotin-modified single-stranded DNA (ssDNA) and streptavidin. To verify the effectiveness of this modified LFIA system, the sensitivity and specificity were evaluated. Sensitivity evaluation showed a broad detection range of 0.25-1000 ng/ml for CEA protein by the modified LFIA, and the limit of detection (LOD) of the modified LFIA was 0.25 ng/ml, thus producing significant increase in detection threshold compared with the traditional LFIA. The modified LFIA could selectively recognize CEA in presence of several interfering proteins. In addition, this newly developed assay was applied for quantitative detection of CEA in human serum specimens collected from 10 randomly selected patients. The modified LFIA system detected minimum 0.27 ng/ml of CEA concentration in serum samples. The results were consistent with the clinical data obtained using commercial electrochemiluminescence immunoassay (ECLIA) (p < 0.01). In conclusion, the MNPs based LFIA system not only demonstrated enhanced signal to noise ratio, it also detected CEA with higher sensitivity and selectivity, and thus has great potential to be commercially applied as a sensitive tumor marker filtration system. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 210
页数:6
相关论文
共 50 条
  • [1] Carbon dots and gold nanoparticles based "sandwich" type immunoassay for sensitive and selective carcinoembryonic antigen detection
    Luo, Yuanping
    Xu, Wenjun
    Zhu, Minjie
    Zhang, Zongwen
    Peng, Zhili
    MICROCHEMICAL JOURNAL, 2025, 212
  • [2] Development of a highly sensitive immunoassay based on pentameric nanobodies for carcinoembryonic antigen detection
    Gu, Yi
    Guo, Yang
    Deng, Yang
    Song, Haipeng
    Nian, Rui
    Liu, Wenshuai
    ANALYTICA CHIMICA ACTA, 2023, 1279
  • [3] Lateral flow immunoassay based on gold magnetic nanoparticles for the protein quantitative detection: Prostate-specific antigen
    Cai, Yu
    Zhang, Shanshan
    Dong, Chen
    Yang, Jiangcun
    Ma, Ting
    Zhang, Hua
    Cui, Yali
    Hui, Wenli
    ANALYTICAL BIOCHEMISTRY, 2021, 627
  • [4] Sensitive detection of carcinoembryonic antigen with magnetic nano-bead and upconversion nanoparticles-based immunoassay
    Huang, Zhaohui
    Wu, Shijia
    Duan, Nuo
    Hua, Dong
    Hu, Yu
    Wang, Zhouping
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 225 - 231
  • [5] Highly sensitive immunoassay of carcinoembryonic antigen by capillary electrophoresis with gold nanoparticles amplified chemiluminescence detection
    Jiang, Jing
    Zhao, Shulin
    Huang, Yong
    Qin, Guoxin
    Ye, Fanggui
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1282 : 161 - 166
  • [6] Highly Sensitive and Quantitative Magnetic Nanoparticle-Based Lateral Flow Immunoassay with an Atomic Magnetometer
    Wang, Boyu
    Peng, Tao
    Jiang, Zhiyuan
    Xu, Jinxin
    Qu, Jifeng
    Dai, Xinhua
    ACS SENSORS, 2023, 8 (12): : 4512 - 4520
  • [7] A fluorescent aptasensor for highly sensitive and selective detection of carcinoembryonic antigen based on upconversion nanoparticles and WS2 nanosheets
    Yuan, Yunxia
    Di, Yi
    Chen, Yuan
    Yu, Huichun
    Li, Ruhuan
    Yu, Songwei
    Li, Fang
    Li, Zhaozhou
    Yin, Yong
    ANALYTICAL METHODS, 2024, 16 (08) : 1225 - 1231
  • [8] Rapid, highly sensitive and quantitative detection of interleukin 6 based on SERS magnetic immunoassay
    Wang, Xiaomei
    Ma, Li
    Sun, Shijiao
    Liu, Tingwei
    Zhou, Hao
    Liu, Xinghui
    Guan, Ming
    ANALYTICAL METHODS, 2021, 13 (15) : 1823 - 1831
  • [9] Dual sensitivity enhancement in gold nanoparticle-based lateral flow immunoassay for visual detection of carcinoembryonic antigen
    Mahmoudi, Tohid
    Shirdel, Behnaz
    Mansoori, Behzad
    Baradaran, Behzad
    ANALYTICAL SCIENCE ADVANCES, 2020, 1 (03): : 161 - 172
  • [10] Magnetic bead-based photoelectrochemical immunoassay for sensitive detection of carcinoembryonic antigen using hollow cadmium sulfide
    Zeng, Ruijin
    Tang, Dianping
    TALANTA, 2020, 219