Pharmacokinetics, safety and efficacy of a recombinant factor IX product, trenonacog alfa in previously treated haemophilia B patients

被引:15
|
作者
Collins, P. W. [1 ]
Quon, D. V. K.
Makris, M. [2 ]
Chowdary, P. [3 ]
Kempton, C. L. [4 ]
Apte, S. J. [5 ]
Ramanan, M. V. [6 ]
Hay, C. R. M. [7 ]
Drobic, B. [8 ]
Hua, Y. [8 ]
Babinchak, T. J. [9 ]
Gomperts, E. D. [10 ]
机构
[1] Cardiff Univ, Sch Med, Arthur Bloom Haemophilia Ctr, Cardiff, S Glam, Wales
[2] Royal Hallamshire Hosp, Dept Haematol, Sheffield, S Yorkshire, England
[3] Royal Free Hosp NHS Trust, Katharine Dormandy Haemophilia Care & Thrombosis, London, England
[4] Emory Univ, Dept Hematol & Med Oncol, Atlanta, GA 30322 USA
[5] Sahyadri Specialty Hosp, Pune, Maharashtra, India
[6] Jehangir Hosp, Jehangir Clin Dev Ctr, Pune, Maharashtra, India
[7] Manchester Haemophilia Comprehens Care Ctr, Manchester, Lancs, England
[8] Emergent BioSolut Canada Inc, Clin Res, Winnipeg, MB, Canada
[9] Emergent BioSolut Inc, Clin Dev & Med Affairs, Berwyn, IL USA
[10] Consultant Emergent BioSolut Inc, Montrose, CO USA
关键词
efficacy; haemophilia B; IB1001; pharmacokinetics; recombinant factor IX; safety; MODERATELY SEVERE; PROTEIN; IB1001;
D O I
10.1111/hae.13324
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionTrenonacog alfa (IB1001) is a recombinant factor IX (rFIX) manufactured in Chinese hamster ovary (CHO) cells. IB1001 was evaluated in a multicentre clinical trial with haemophilia B patients. AimThe aim was to establish IB1001 pharmacokinetic non-inferiority to comparator rFIX, safety and efficacy in previously treated patients (PTPs) with haemophilia B. MethodsSubjects were severe or moderately severe haemophilia B adult and adolescent PTPs with no history of FIX inhibitors. ResultsIB1001 PK non-inferiority to comparator rFIX was demonstrated through ratio of AUC(0-) in 32 subjects. IB1001 was well tolerated in all 76 treated subjects; the most common adverse drug reaction was headache (2.6% of subjects) and there were no reports of FIX inhibitors. Transient non-inhibitory binding FIX antibodies and anti-CHO cell protein antibodies developed in 21% and 29% of subjects respectively; no safety concerns were associated with development of these antibodies. Prophylaxis (mean durationSD: 17.9 +/- 9.6months, mean dose: 55.5 +/- 12.9IU/kg, median 1.0 infusion per week) was effective in preventing bleeds (median annual bleed rate: 1.52, interquartile range: 0.0-3.46). One or two IB1001 infusions resolved 84% of the bleeds, while for 84% of treatments haemostatic efficacy of IB1001 was rated excellent or good. IB1001 haemostatic efficacy for all 19 major surgeries was rated adequate or better than adequate. ConclusionsIB1001 is safe and efficacious for treatment of bleeds, routine prophylaxis and perioperative management in haemophilia B patients.
引用
收藏
页码:104 / 112
页数:9
相关论文
共 50 条
  • [21] Evaluation of pharmacokinetics, efficacy and safety of Immunate® solvent detergent in previously treated patients with severe haemophilia A
    Nemes, L.
    Lissitchkov, T.
    Klukowska, A.
    Dobaczewski, G.
    Komrska, V.
    Zimmermann, R.
    Auerswald, G.
    Engl, W.
    Pavlova, B.
    Abbuehl, B.
    Ehrilch, H. J.
    [J]. HAEMOPHILIA, 2007, 13 (01) : 9 - 11
  • [22] The use of recombinant factor VIII products in previously treated patients with hemophilia A: Pharmacokinetics, efficacy, safety, and inhibitor development
    Lee, C
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2002, 28 (03): : 241 - 246
  • [23] Plasma and albumin-free recombinant factor VIII: pharmacokinetics, efficacy and safety in previously treated pediatric patients
    Blanchette, V. S.
    Shapiro, A. D.
    Liesner, R. J.
    Navarro, F. Hernandez
    Warrier, I.
    Schroth, P. C.
    Spotts, G.
    Ewenstein, B. M.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2008, 6 (08) : 1319 - 1326
  • [24] Prospective study of a novel recombinant factor IX in previously treated patients with hemophilia B
    Windyga, J.
    Lissitchkov, T.
    Stasyshyn, O.
    Mamonov, V
    Oh, M-S
    Chapman, M.
    Pavlova, B. G.
    Wong, W. Y.
    Abbuehl, B. E.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 830 - 830
  • [25] Recombinant factor IX in the treatment of previously-treated patients with hemophilia B.
    White, G
    Lusher, J
    Shapiro, A
    Tubridy, K
    Courter, S
    [J]. BLOOD, 1996, 88 (10) : 1296 - 1296
  • [26] Efficacy and inhibitor development in previously treated patients with haemophilia A switched to a B domain-deleted recombinant factor VIII
    Gringeri, A
    Tagliaferri, A
    Tagariello, G
    Morfini, M
    Santagostino, E
    Mannucci, P
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 2004, 126 (03) : 398 - 404
  • [27] Pharmacokinetics of a new B-domain truncated recombinant factor VIII (turoctocog alfa) in patients with haemophilia A
    Jimenez-Yuste, V.
    Lejniece, S.
    Klamroth, R.
    Suzuki, T.
    Santagostino, E.
    Karim, F. Abdul
    Saugstrup, T.
    Moss, J.
    [J]. HAEMOPHILIA, 2014, 20 : 30 - 31
  • [28] Pharmacokinetics, Efficacy and Safety Of a Recombinant Factor IX (BAX326) In Previously-Treated Pediatric Patients < 12 Years Of Age With Severe Or Moderately Severe Hemophilia B
    Urasinski, Tomasz
    Stasyshyn, Oleksandra
    Andreeva, Tatiana
    Rusen, Luminita
    Perina, Farida
    Oh, MyungShin
    Chapman, Miranda
    Pavlova, Borislava G.
    Wong, Wing Yen
    Abbuehl, Brigitt E.
    [J]. BLOOD, 2013, 122 (21)
  • [29] Evaluation of the safety and efficacy of recombinant factor VIII (moroctocog alfa [AF-CC]) in minimally treated and previously treated chinese patients with hemophilia A
    Renchi, Y.
    Zhao, Y.
    Wang, X.
    Sun, J.
    Jin, J.
    Wu, D.
    Charnigo, R.
    O'Brien, A.
    Kollmer, C.
    Rendo, P.
    Zhong, Z.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 357 - 357
  • [30] Recombinant factor IX is an effective and safe replacement therapy for previously treated patients with hemophilia B
    Kessler, C
    Poon, M
    Negrier, C
    Fernands, A
    Gencarella, N
    [J]. THROMBOSIS AND HAEMOSTASIS, 1999, : 331 - 331