Optimisation of Glucose Biosensors Based on Sol-Gel Entrapment and Prussian Blue-Modified Screen-Printed Electrodes for Real Food Analysis

被引:21
|
作者
Albanese, Donatella [1 ]
Sannini, Adriana [1 ]
Malvano, Francesca [1 ]
Pilloton, Roberto [2 ]
Di Matteo, Marisa [1 ]
机构
[1] Univ Salerno, Dept Ind Engn, I-84084 Fisciano, SA, Italy
[2] CNR, Inst Photon & Nanotechnol CNR IFN, I-00156 Rome, Italy
关键词
Glucose biosensor; Prussian Blue; Screen-printed electrodes; Food analysis; ASCORBIC-ACID; IMMOBILIZATION; OXIDASE; ENZYME; FILM; CONSTRUCTION; STABILITY; MEMBRANES; SENSOR; GOLD;
D O I
10.1007/s12161-013-9705-6
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, we report the construction of amperometric screen-printed glucose biosensors for food analysis by using two procedures for Prussian Blue (PB) deposition and different membranes for enzymatic immobilisation. The comparison between the screen-printed electrodes modified with PB by electrochemical and chemical deposition showed higher analytical performance (detection limit of 1 mu M, linear range from 0.5 to 500 mu M and a sensitivity of 823 mu A mM(-1) cm(-2)) when the latter was employed. Then, the immobilisation of glucose oxidase (GOD) by silica sol-gel and polyvinyl alcohol (PVA) hydrogel was performed on electrochemically modified PB electrodes. The electrochemical response of two glucose biosensors was evaluated by flow injection analysis. Biosensors constructed by silica sol-gel entrapment showed a wider linear range (0.005-1 mM) and a detection limit (0.02 mM) that was 10-fold lower than using entrapped GOD in PVA. The selected glucose biosensor showed negligible interference from ascorbic acid when the Nafion membrane was used to cover the PB-modified electrode surface. Additionally, it exhibited an operating lifetime of 8 h under continuous glucose injections ranging from 0.01 to 2 mM. Finally, the biosensor was applied for specific determination of glucose in red and white wines, juices and dried fruit.
引用
收藏
页码:1002 / 1008
页数:7
相关论文
共 50 条
  • [31] Cholesterol biosensors based on cholesterol oxidase immobilized in a silica sol-gel matrix on a Prussian blue modified electrode
    Li, Jian-Ping
    Peng, Tu-Zhi
    Gaodeng Xuexiao Huaxue Xuebao/Chemical Journal of Chinese Universities, 2003, 24 (05):
  • [32] Improvement of NADH detection using Prussian blue modified screen-printed electrodes and different strategies of immobilisation
    Gurban, Ana-Maria
    Noguer, Thierry
    Bala, Camelia
    Rotariu, Lucian
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 128 (02) : 536 - 544
  • [33] Detection of sodium ion in aqueous soil extract using Prussian blue modified screen-printed electrodes
    Gonzalez-Nava, V. J.
    Solis-Valdez, S.
    Manriquez, J.
    Sepulveda-Guzman, S.
    Stortini, A. M.
    Bustos, E.
    ELECTROCHIMICA ACTA, 2025, 513
  • [34] A Choline Oxidase Amperometric Bioassay for the Detection of Mustard Agents Based on Screen-Printed Electrodes Modified with Prussian Blue Nanoparticles
    Arduini, Fabiana
    Scognamiglio, Viviana
    Covaia, Corrado
    Amine, Aziz
    Moscone, Danila
    Palleschi, Giuseppe
    SENSORS, 2015, 15 (02): : 4353 - 4367
  • [35] Electrode Kinetics of Ion Jelly and Ion Sol-Gel Redox Materials on Screen-Printed Electrodes
    Carvalho, Rui N. L.
    Cordas, Cristina M.
    da Fonseca, Luis J. P.
    APPLIED SCIENCES-BASEL, 2022, 12 (04):
  • [36] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    TENG YuanJie
    Research Center of Analysis Test
    Science China(Chemistry), 2010, (12) : 2581 - 2586
  • [37] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    TENG YuanJieCHEN ChenZHOU ChangXiangZHAO HongLi LAN MinBo Shanghai key Laboratory of Functional Materials Chemistry
    Research Center of Analysis TestEast China University of Science and TechnologyShanghai China
    Science China(Chemistry), 2010, 53 (12) : 2581 - 2586
  • [38] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    Teng YuanJie
    Chen Chen
    Zhou ChangXiang
    Zhao HongLi
    Lan MinBo
    SCIENCE CHINA-CHEMISTRY, 2010, 53 (12) : 2581 - 2586
  • [39] Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens
    Vasilescu, Alina
    Nunes, Gilvanda
    Hayat, Akhtar
    Latif, Usman
    Marty, Jean-Louis
    SENSORS, 2016, 16 (11)
  • [40] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    YuanJie Teng
    Chen Chen
    ChangXiang Zhou
    HongLi Zhao
    MinBo Lan
    Science China Chemistry, 2010, 53 : 2581 - 2586