Reusable Fundus Model for Laser Retinopexy Simulation and Training

被引:0
|
作者
Hudson, Julia L. [1 ]
Salazar, Humberto [1 ]
Kunkler, Anne L. [1 ]
Fan, Kenneth C. [1 ]
Sridhar, Jayanth S. [1 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Dept Ophthalmol, Miami, FL 33136 USA
来源
关键词
D O I
10.3928/23258160-20221019-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To describe a simulation technique for laser barrier retinopexy as an option for ophthalmologists in training to practice slit lamp and laser indirect ophthalmoscopy (LIO) retinopexy. MATERIALS AND METHODS: A commercially available fundus model and laser printer labels were used to simulate laser retinopexy of horseshoe tears (HST). At two time points, seven first-year residents and seven second-year residents were asked to complete three rows of laser burns around HSTs and the times were recorded. RESULTS: Second-year residents completed simulated retinopexies in less time than first-year residents on both the slit lamp (P =.001) and with LIO (P =.001). Second-year residents were also statistically more efficient when retested at the second time point (P =.003 and P =.005, slit lamp and LIO, respectively). CONCLUSION: This novel educational model is able to capture differences in training level and increased experience among ophthalmology trainees, and may be beneficial as part of a structured teaching program.
引用
收藏
页码:606 / 609
页数:4
相关论文
共 50 条
  • [11] The design of the laser simulation training device
    Sun Rong-xia
    Chen Xiaofeng
    THIRD INTERNATIONAL CONFERENCE ON KNOWLEDGE DISCOVERY AND DATA MINING: WKDD 2010, PROCEEDINGS, 2010, : 71 - 74
  • [12] Relationship of Gender With Laser Retinopexy for Retinal Breaks
    Hussain, Syed Zohaib Maroof
    Jeeva, Irfan
    Siddiqui, M. A. Rehman
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [13] Reusable Component Model Development Approach for Parallel and Distributed Simulation
    Zhu, Feng
    Yao, Yiping
    Chen, Huilong
    Yao, Feng
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [14] A Novel, Reusable, Ultrasound-Guided Pericardiocentesis Simulation Model
    Pezeshki, Bryan
    Boodaie, Benjamin
    Kessel, Matthew
    Grewal, Ekjot
    Alexander, Dorian
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (08) : 1657 - 1663
  • [15] A library of reusable model components for visual simulation of the NCSTRL system
    Balci, O
    Ulusaraç, C
    Shah, P
    Fox, EA
    1998 WINTER SIMULATION CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 1451 - 1459
  • [16] A metamodel-based representation method for reusable simulation model
    Lei, Yonglin
    Song, Lili
    Wang, Weiping
    Jiang, Caiyun
    PROCEEDINGS OF THE 2007 WINTER SIMULATION CONFERENCE, VOLS 1-5, 2007, : 830 - 837
  • [17] Preventing Retinal Detachment: The Encircling Laser Retinopexy Technique
    Morris, Robert E.
    Kuhn, Ferenc
    Richardson, Cole
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 1505 - 1513
  • [18] TRANSSCLERAL RETINOPEXY WITH A CW ND-YAG LASER
    MESSMER, E
    FANKHAUSER, F
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S849 - S849
  • [19] Frugal retinal laser training simulation eyes
    Kousha, Obaid
    Staniszewski, Blazej
    Ulloa, Juan Lopez
    Tarafdar, Sonali
    Ellis, John
    Blaikie, Andrew
    EYE, 2022, 36 (05) : 1129 - 1130
  • [20] ND-YAG LASER AUGMENTED PNEUMATIC RETINOPEXY
    FLECK, BW
    DHILLON, BJ
    KHANNA, V
    MCCONNELL, JMS
    CHAWLA, HB
    OPHTHALMIC SURGERY AND LASERS, 1988, 19 (12): : 855 - 858