Introduction of Ultra-High-Field MR Imaging in Infants: Preparations and Feasibility

被引:12
|
作者
Annink, K., V [1 ]
van der Aa, N. E. [1 ]
Dudink, J. [1 ]
Alderliesten, T. [1 ]
Groenendaal, F. [1 ]
Lequin, M. [3 ]
Jansen, F. E. [2 ]
Rhebergen, K. S. [4 ]
Luijten, P. [3 ]
Hendrikse, J. [3 ]
Hoogduin, H. J. M. [3 ]
Huijing, E. R. [3 ]
Versteeg, E. [3 ]
Visser, F. [3 ]
Raaijmakers, A. J. E. [3 ]
Wiegers, E. C. [3 ]
Klomp, D. W. J. [3 ]
Wijnen, J. P. [3 ]
Benders, M. J. N. L. [1 ]
机构
[1] Univ Med Ctr Utrecht, Brain Ctr, Dept Neonatol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Paediat Neurol, Utrecht, Netherlands
[3] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[4] Univ Utrecht, Univ Med Ctr Utrecht, Dept Otorhinolaryngol & Head & Neck Surg, Utrecht, Netherlands
基金
欧盟地平线“2020”;
关键词
3; T; BRAIN; SAFETY;
D O I
10.3174/ajnr.A6702
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Cerebral MR imaging in infants is usually performed with a field strength of up to 3T. In adults, a growing number of studies have shown added diagnostic value of 7T MR imaging. 7T MR imaging might be of additional value in infants with unexplained seizures, for example. The aim of this study was to investigate the feasibility of 7T MR imaging in infants. We provide information about the safety preparations and show the first MR images of infants at 7T. MATERIALS AND METHODS: Specific absorption rate levels during 7T were simulated in Sim4life using infant and adult models. A newly developed acoustic hood was used to guarantee hearing protection. Acoustic noise damping of this hood was measured and compared with the 3T Nordell hood and no hood. In this prospective pilot study, clinically stable infants, between term-equivalent age and the corrected age of 3 months, underwent 7T MR imaging immediately after their standard 3T MR imaging. The 7T scan protocols were developed and optimized while scanning this cohort. RESULTS: Global and peak specific absorption rate levels in the infant model in the centered position and 50-mm feet direction did not exceed the levels in the adult model. Hearing protection was guaranteed with the new hood. Twelve infants were scanned. No MR imaging-related adverse events occurred. It was feasible to obtain good-quality imaging at 7T for MRA, MRV, SWI, single-shot T2WI, and MR spectroscopy. T1WI had lower quality at 7T. CONCLUSIONS: 7T MR imaging is feasible in infants, and good-quality scans could be obtained.
引用
收藏
页码:1532 / 1537
页数:6
相关论文
共 50 条
  • [31] Ultra-high-field magnetic resonance: Why and when?
    Moser, Ewald
    WORLD JOURNAL OF RADIOLOGY, 2010, 2 (01): : 37 - 40
  • [32] Progress of ultra-high-field superconducting magnets in China
    Wang, Qiuliang
    Liu, Jianhua
    Zheng, Jinxing
    Qin, Jinggang
    Ma, Yanwei
    Xu, Qingjin
    Wang, Dongliang
    Chen, Wenge
    Qu, Timing
    Zhang, Xingyi
    Jiang, Donghui
    Wang, Yaohui
    Zhou, Benzhe
    Qin, Lang
    Jin, Huan
    Liu, Huajun
    Zhai, Yujia
    Liu, Feng
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2022, 35 (02):
  • [33] Microvascular functional MR angiography with ultra-high-field 7 t MRI: Comparison with BOLD fMRI
    Cho, Zang-Hee
    Kang, Chang-Ki
    Park, Chan-A
    Hong, Suk-Min
    Kim, Sang-Hoon
    Oh, Seung-Taek
    Kim, Young-Bo
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2012, 22 (01) : 18 - 22
  • [34] Synthesizing PET images from high-field and ultra-high-field MR images using joint diffusion attention model
    Xie, Taofeng
    Cao, Chentao
    Cui, Zhuo-xu
    Guo, Yu
    Wu, Caiying
    Wang, Xuemei
    Li, Qingneng
    Hu, Zhanli
    Sun, Tao
    Sang, Ziru
    Zhou, Yihang
    Zhu, Yanjie
    Liang, Dong
    Jin, Qiyu
    Zeng, Hongwu
    Chen, Guoqing
    Wang, Haifeng
    MEDICAL PHYSICS, 2024, 51 (08) : 5250 - 5269
  • [35] Ultra-high-field imaging distinguishes MS lesions from asymptomatic white matter lesions
    Tallantyre, E. C.
    Dixon, J. E.
    Donaldson, I.
    Owens, T.
    Morgan, P. S.
    Morris, P. G.
    Evangelou, N.
    NEUROLOGY, 2011, 76 (06) : 534 - 539
  • [36] Moyamoya Vessel Pathology Imaged by Ultra-High-Field Magnetic Resonance Imaging at 7.0 T
    Dengler, Nora F.
    Madai, Vince I.
    Wuerfel, Jens
    von Samson-Himmelstjerna, Federico C.
    Dusek, Petr
    Niendorf, Thoralf
    Sobesky, Jan
    Vajkoczy, Peter
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2016, 25 (06): : 1544 - 1551
  • [37] First Clinical Study on Ultra-High-Field MR Imaging in Patients with Multiple Sclerosis: Comparison of 1.5T and 7T
    Kollia, K.
    Maderwald, S.
    Putzki, N.
    Schlamann, M.
    Theysohn, J. M.
    Kraff, O.
    Ladd, M. E.
    Forsting, M.
    Wanke, I.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (04) : 699 - 702
  • [38] In vivo ultra-high-field magnetic resonance imaging of trabecular bone microarchitecture at 7 T
    Krug, Roland
    Carballido-Gamio, Julio
    Banerjee, Suchandrima
    Burghardt, Andrew J.
    Link, Thomas M.
    Majumdar, Sharmila
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 854 - 859
  • [39] Ultra-high-field MRI improves detection of epileptic lesions
    Wood, Heather
    NATURE REVIEWS NEUROLOGY, 2020, 16 (12) : 654 - 654
  • [40] Characterization of a miniature, ultra-high-field, ion mobility spectrometer
    Wilks, Ashley
    Hart, Matthew
    Koehl, Andrew
    Somerville, John
    Boyle, Billy
    Ruiz-Alonso, David
    INTERNATIONAL JOURNAL FOR ION MOBILITY SPECTROMETRY, 2012, 15 (03) : 199 - 222