Introduction of Ultra-High-Field MR Imaging in Infants: Preparations and Feasibility

被引:12
|
作者
Annink, K., V [1 ]
van der Aa, N. E. [1 ]
Dudink, J. [1 ]
Alderliesten, T. [1 ]
Groenendaal, F. [1 ]
Lequin, M. [3 ]
Jansen, F. E. [2 ]
Rhebergen, K. S. [4 ]
Luijten, P. [3 ]
Hendrikse, J. [3 ]
Hoogduin, H. J. M. [3 ]
Huijing, E. R. [3 ]
Versteeg, E. [3 ]
Visser, F. [3 ]
Raaijmakers, A. J. E. [3 ]
Wiegers, E. C. [3 ]
Klomp, D. W. J. [3 ]
Wijnen, J. P. [3 ]
Benders, M. J. N. L. [1 ]
机构
[1] Univ Med Ctr Utrecht, Brain Ctr, Dept Neonatol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Paediat Neurol, Utrecht, Netherlands
[3] Univ Utrecht, Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[4] Univ Utrecht, Univ Med Ctr Utrecht, Dept Otorhinolaryngol & Head & Neck Surg, Utrecht, Netherlands
基金
欧盟地平线“2020”;
关键词
3; T; BRAIN; SAFETY;
D O I
10.3174/ajnr.A6702
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Cerebral MR imaging in infants is usually performed with a field strength of up to 3T. In adults, a growing number of studies have shown added diagnostic value of 7T MR imaging. 7T MR imaging might be of additional value in infants with unexplained seizures, for example. The aim of this study was to investigate the feasibility of 7T MR imaging in infants. We provide information about the safety preparations and show the first MR images of infants at 7T. MATERIALS AND METHODS: Specific absorption rate levels during 7T were simulated in Sim4life using infant and adult models. A newly developed acoustic hood was used to guarantee hearing protection. Acoustic noise damping of this hood was measured and compared with the 3T Nordell hood and no hood. In this prospective pilot study, clinically stable infants, between term-equivalent age and the corrected age of 3 months, underwent 7T MR imaging immediately after their standard 3T MR imaging. The 7T scan protocols were developed and optimized while scanning this cohort. RESULTS: Global and peak specific absorption rate levels in the infant model in the centered position and 50-mm feet direction did not exceed the levels in the adult model. Hearing protection was guaranteed with the new hood. Twelve infants were scanned. No MR imaging-related adverse events occurred. It was feasible to obtain good-quality imaging at 7T for MRA, MRV, SWI, single-shot T2WI, and MR spectroscopy. T1WI had lower quality at 7T. CONCLUSIONS: 7T MR imaging is feasible in infants, and good-quality scans could be obtained.
引用
收藏
页码:1532 / 1537
页数:6
相关论文
共 50 条
  • [1] Introduction of Ultra-High-Field MR Imaging in Infants: Preparations and Feasibility (vol 41, pg 1532, 2020)
    Annink, K. V.
    van der Aa, N. E.
    Dudink, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (10) : E41 - E42
  • [2] Ultra-High-Field MR Imaging in Polymicrogyria and Epilepsy
    De Ciantis, A.
    Barkovich, A. J.
    Cosottini, M.
    Barba, C.
    Montanaro, D.
    Costagli, M.
    Tosetti, M.
    Biagi, L.
    Dobyns, W. B.
    Guerrini, R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) : 309 - 316
  • [3] Ultra-high-field MR in Prostate cancer: Feasibility and Potential
    Tenbergen, Carlijn J. A.
    Metzger, Gregory J.
    Scheenen, Tom W. J.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (04) : 631 - 644
  • [4] Ultra-high-field MR imaging in multiple sclerosis
    Filippi, Massimo
    Evangelou, Nikos
    Kangarlu, Alayar
    Inglese, Matilde
    Mainero, Caterina
    Horsfield, Mark A.
    Rocca, Maria A.
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2014, 85 (01): : 60 - 66
  • [5] Ultra-high-field MR in Prostate cancer: Feasibility and Potential
    Carlijn J. A. Tenbergen
    Gregory J. Metzger
    Tom W. J. Scheenen
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 631 - 644
  • [6] Ultra-High-Field MR Neuroimaging
    Balchandani, P.
    Naidich, T. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (07) : 1204 - 1215
  • [7] CHARACTERIZATION OF GLIOMA USING ULTRA-HIGH-FIELD MR SPECTROSCOPIC IMAGING
    Li, Yan
    Larson, Peder
    Chen, Albert
    Lupo, Janine M.
    Kelley, Douglas
    Chang, Susan
    Nelson, Sarah J.
    NEURO-ONCOLOGY, 2012, 14 : 126 - 126
  • [8] Ultra-high-field MRI
    Reich, D. S.
    MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 25 - 25
  • [9] Ultra-High-Field Imaging of the Pediatric Brain and Spinal Cord
    Deelchand, Dinesh Kumar
    Ho, Mai-Lan
    Nestrasil, Igor
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2021, 29 (04) : 643 - 653
  • [10] ULTRA-HIGH-FIELD SUPERCONDUCTIVITY
    JACCARINO, V
    PETER, M
    PHYSICAL REVIEW LETTERS, 1962, 9 (07) : 290 - +