GTEM cell as an Alternative Method for Radiated Immunity Tests A comparison with an Anechoic Chamber

被引:0
|
作者
Salhi, Mohammed A. [1 ]
Cakir, Soydan [1 ]
Cinar, Mehmet [1 ]
Tektas, Bahadir [1 ]
Cetintas, Mustafa [1 ]
机构
[1] TUBITAK Ulusal Metrol Enstitusu UME, Electromagnet Compatibil Dept, Gebze, Turkey
关键词
EMC; GTEM cell; Anechoich chamber; radiated immunity; Alternative Test Methods;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radiated immunity tests are among the main Electromagnetic Compatibility (EMC) prerequisites which need to be met for any electrical and electronic product before entering the market. That gave this topic a great interest by the stakeholders from industry, where such tests are commonly performed. In general, EMC tests are performed using alternative methods since tests in laboratories are either costly or technically not possible due to different hurdles. GTEM cells are widely used for radiated immunity tests as an alternative to anechoic chambers. In this paper we present an experimental investigation of this method according to the standard EN61000-4-20 on self-made metallic Equipment Under Test (EUT) to simulate products in industrial environment. Under the same conditions and using the same receiver cables, we also present a comparison between this method and the common method employing a semi-anechoic chamber according to the standard EN61000-4-3.
引用
收藏
页码:251 / 256
页数:6
相关论文
共 41 条
  • [21] Comparison of site attenuation analysis results between FDTD and ray-tracing method using compact anechoic chamber
    Kawabata, M
    Ishida, Y
    Shimada, K
    Kuwabara, N
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2005, E88B (08) : 3152 - 3157
  • [22] A comparison of methods and results using the semi-anechoic and reverberation chamber radiated RF susceotibility test procedures in RTCA/DO-160D, change one
    Borgstrom, EJ
    2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, SYMPOSIUM RECORD, 2002, : 184 - 188
  • [23] A comparison of methods and results using the semi-anechoic and reverberation chamber radiated RF susceptibility test procedures in RTCA/DO-160D, change one
    Borgstrom, EJ
    2004 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SYMPOSIUM RECORD 1-3, 2004, : 245 - 250
  • [24] Comparison of Active Levelling and Pre-Calibrating/Substitution Method for Radiated Immunity Testing of Large Equipment
    Mandaris, Dwi
    Cakir, Soydan
    Sen, Osman
    Jimenez Lorenzo, Maria
    Lopez Sanz, Daniel
    Svoboda, Marek
    Hamouz, Pavel
    Leferink, Frank
    PROCEEDINGS OF THE 2016 INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY - EMC EUROPE, 2016, : 507 - 513
  • [25] Comparison Test and Error Analysis of the TEM Cell Method in IC Radiated Emission
    Li, Y.
    Wu, J.
    Li, H.
    Zhang, H.
    Ma, H.
    Wu, J.
    2018 JOINT IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY AND 2018 IEEE ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC/APEMC), 2018, : 1208 - 1211
  • [26] Estimating Termination Effect on Electric and Magnetic Field-to-Line Coupling for Radiated Immunity Tests Using a TEM Cell
    Shi, Chunlei
    Chai, Changchun
    Yang, Yintang
    Fang, Wenxiao
    PROGRESS IN ELECTROMAGNETICS RESEARCH LETTERS, 2016, 60 : 39 - 44
  • [27] Radiated electromagnetic field immunity test method for wireless LAN using opened parallel wired cell
    Tokuda, M
    Kitora, M
    Honma, Y
    Ichikawa, K
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2005, E88B (08) : 3229 - 3234
  • [28] New radiated immunity/susceptibility test method using four-septum TEM cell: Measurements and field analysis
    Murano, Kimitoshi
    Kawahara, Hiroko
    Tayarani, Majid
    Xiao, Fengchao
    Kami, Yoshio
    2007 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY: WORKSHOP AND TUTORIAL NOTES, VOLS 1-3, 2007, : 719 - +
  • [29] Comparison of 1D transfer matrix method and finite element method with tests for acoustic performance of multi-chamber perforated resonator
    Guo, Rong
    Tang, Wen-bo
    Zhu, Wei-wei
    APPLIED ACOUSTICS, 2016, 112 : 140 - 146
  • [30] An alternative test for determining autologous stem cell transplantation cell harvesting outcome: Comparison between predictive values of two tests
    Mohammadi, Saeed
    Jalili, Mahdi
    Mohammadi, Ashraf Malek
    Nikbahht, Mohsen
    Aminian, Privash
    Bagherian, Maryam
    Mousavi, Syed Asadollah
    Heshmati, Farhad
    TRANSFUSION AND APHERESIS SCIENCE, 2020, 59 (04)