The Limit of the Lateral Fundamental Frequency and Comfort Analysis of a Straddle-Type Monorail Tour Transit System

被引:3
|
作者
Guo, Fengqi [1 ]
Ji, Yanqiang [1 ]
Liao, Qiaoyun [2 ]
Liu, Bo [2 ]
Li, Chenjia [1 ]
Wei, Shiqi [1 ]
Xiang, Ping [1 ]
机构
[1] Cent South Univ, Sch Civil Engn, Changsha 410075, Peoples R China
[2] Zhuzhou CRRC Special Equipment Technol Co Ltd, Zhuzhou 412004, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 20期
关键词
straddle-type monorail tour transit system; lateral vibration; human-induced vibration; comfort level; VERTICAL BENDING VIBRATION; RAILWAY; SUPPRESSION; REDUCTION; BODY;
D O I
10.3390/app122010434
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The straddle-type monorail tour transit system is a light overhead steel structure, and the lateral stiffness is generally low. However, the limit of the lateral natural vibration frequency is not clear in the current codes of China, and designers may ignore it. Weak lateral stiffness will lead to a violent vibration during vehicle operation and crowds walking, affecting human comfort and structural safety. Based on a practical project, we tested the acceleration of a monorail vehicle under full load conditions, and its running stability and ride comfort were assessed. Then, the impact of pedestrians on lateral vibration under some working conditions was measured and analyzed. Furthermore, the influence of different structural parameters on the lateral fundamental frequency was investigated. The results showed the following: (i) The vehicle's running stability and riding comfort was good. However, human comfort was poor due to the weak lateral stiffness of the structure, which was affected by human-induced vibration. (ii) The comprehensive response of the structure increased with the increase in walking frequency, increased with the increase in the number of people working or weight, and the growth speed slowed down. (iii) The structural stiffness was most sensitive to the change in steel column diameter. (iv) The recommended value of the lateral fundamental frequency limit for different spans of the straddle-type monorail tour transit system was put forward. The recommended lower limit of fundamental frequency for a 15 m span is 5.0 Hz, for an 18 m span it is 3.5 Hz, and for a 25 m span it is 2.8 Hz.
引用
收藏
页数:18
相关论文
共 27 条
  • [21] VEHICLE-BRIDGE COUPLING VIBRATION ANALYSIS ON SLIDING TURNOUT GIRDER OF STRADDLE-TYPE MONORAIL TRANSPORTATION
    Lu, M. Q.
    Zhang, X. T.
    ENVIRONMENTAL VIBRATIONS: PREDICTION, MONITORING, MITIGATION AND EVALUATION, VOLS I AND II, 2009, : 1092 - 1095
  • [22] Operational safety assessment of straddle-type monorail vehicle system based on cloud model and improved CRITIC method
    Wen, Xiaoxia
    Nie, Yi
    Du, Zixue
    Huang, Linkui
    ENGINEERING FAILURE ANALYSIS, 2022, 139
  • [23] Random vibration analysis of the straddle type monorail train-bridge system
    Zhou Z.
    Xiao S.
    He X.
    Jian Z.
    Cai C.
    Journal of Railway Science and Engineering, 2023, 20 (11) : 4210 - 4220
  • [24] Sensitivity-based, space rod system multi-objective design of straddle-type monorail vehicle with single-axle bogies
    Zhou, Junchao
    Zhang, Binghao
    Yin, Jilong
    Gao, Jianjie
    Liao, Yinghua
    Liu, Fuhua
    MECHANICS BASED DESIGN OF STRUCTURES AND MACHINES, 2024, 52 (02) : 611 - 627
  • [25] Curving Performance of Straddle-Type Monorail Vehicle with Single-Axle Bogies Based on Spatial Multi-Body Dynamic Analysis
    Zhou, Junchao
    Du, Zixue
    Yang, Zhen
    Xu, Zhouzhou
    MECHANIKA, 2021, 27 (02): : 148 - 154
  • [26] Dynamic analysis of a coupled system of a monorail train of straddle type and a continuous track beam
    School of Civil Engineering and Architecture, Central South University, Changsha 410075, China
    J Vib Shock, 2009, 7 (139-142):
  • [27] Optimisation of Longitudinal Seismic Energy Dissipation System for Straddle-type Monorail-Cum-Road Long-Span Cable-Stayed Bridge
    Liang, Xiong
    Li, Baomu
    Liu, Xiaolu
    Liang, Linong
    SHOCK AND VIBRATION, 2019, 2019