Mechanical properties of cervical dura mater

被引:1
|
作者
Mazgajczyk, Emilia [1 ]
Scigala, Krzysztof [3 ]
Czyz, Marcin [2 ]
Jarmundowicz, Wlodzimierz [2 ]
Bedzinski, Romuald [3 ]
机构
[1] Wroclaw Univ Technol, Fac Mech Engn, Ctr Adv Mat Technol, PL-50370 Wroclaw, Poland
[2] Wroclaw Univ Hosp, Dept Neurosurg, Wroclaw, Poland
[3] Wroclaw Univ Technol, Fac Mech Engn, PL-50371 Wroclaw, Poland
关键词
dura mater; mechanical properties; orthotropy; tensile test; FINITE-ELEMENT APPROACH; SPINAL-CORD-INJURY; MODEL; MATTER; WHITE;
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The aim of the study was to determine experimentally the stress as strain function as well as the orthotropy and heterogeneity of porcine dura mater of the cervical spinal cord. Material was divided into groups based on the place of collection, considering the dorsal side and ventral side, specifying the number of cervical vertebra, and the direction of tension of the sample - longitudinal or circumferential. Experimental studies were conducted with the MTS Synergie 100 testing machine. The tensile test was performed for each sample at a speed of 2 mm/min until the sample's break. There were determined the characteristics of stress as a function of strain in particular samples. Distribution maps of the stress and strain values at the characteristic points were then drawn (the beginning and the end of the linear range of the stress-strain characteristic and the point corresponding to the complete sample damage) for each set of samples, taking account of their collection place and direction of tension. The results confirmed the orthotropy of mechanical properties of dura mater. Stress and strain differed also in the value at the height of each vertebra and exhibited diversification on the ventral side compared to dorsal one.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [21] Mechanical behavior of fetal dura mater under large axisymmetric inflation
    Kriewall, T.J.
    Akkas, N.
    Bylski, D.I.
    Journal of Biomechanical Engineering, 1983, 105 (01) : 71 - 76
  • [22] INFLUENCE OF FREEZE-DRYING AND GAMA STERILIZATION ON THE MECHANICAL-PROPERTIES OF HUMAN DURA MATER GRAFTS
    PETROV, N
    MECHKARSKY, S
    BIORHEOLOGY, 1978, 15 (5-6) : 492 - 492
  • [23] A sewing needle in contact with the cervical dura mater and vertebral artery A case report
    Fumihiro, Arizumi
    Shinichi, Inoue
    Toshiya, Tachibana
    Keishi, Maruo
    Shinichi, Yoshiya
    MEDICINE, 2016, 95 (52)
  • [24] MECHANICAL-BEHAVIOR OF FETAL DURA MATER IN AXISYMMETRIC BIAXIAL TENSION
    BYLSKI, DI
    KRIEWALL, TJ
    AKKAS, N
    MELVIN, JW
    JOURNAL OF BIOMECHANICS, 1985, 18 (03) : 228 - 228
  • [25] Rupture of the dura mater in two dogs caused by the peracute extrusion of a cervical disc
    McKee, W. M.
    Downes, C. J.
    VETERINARY RECORD, 2008, 162 (15) : 479 - 481
  • [26] Control of rabbit dura mater optical properties with osmotical liquids
    Yao, L
    Cheng, HY
    Luo, QM
    Zhang, W
    Zeng, SQ
    Tuchin, VV
    INTERNATIONAL WORKSHOP ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE, 2001, 4536 : 147 - 152
  • [27] ALLOGRAFT DURA MATER MYRINGOPLASTY
    FROOTKO, NJ
    TING, A
    FABRE, JW
    CLINICAL OTOLARYNGOLOGY, 1982, 7 (02): : 134 - 135
  • [28] PIGMENT IN DURA MATER OF MAMMALS
    SOKOLOV, W
    NATURE, 1963, 198 (487) : 105 - &
  • [29] ANATOMIC AND BIOMECHANICAL PROPERTIES OF HUMAN LUMBAR DURA-MATER
    PATIN, DJ
    ECKSTEIN, EC
    HARUM, K
    PALLARES, VS
    ANESTHESIA AND ANALGESIA, 1993, 76 (03): : 535 - 540
  • [30] The swelling of the dura mater.
    Engert, F