Handheld X-ray Fluorescence Spectrometers: Radiation Exposure Risks of Matrix-Specific Measurement Scenarios

被引:6
|
作者
Rouillon, Marek [1 ]
Kristensen, Louise J. [1 ]
Gore, Damian B. [1 ]
机构
[1] Macquarie Univ, Fac Sci & Engn, Dept Environm Sci, Sydney, NSW 2109, Australia
关键词
Radiation; X-ray fluorescence; XRF; Handheld XRF; Exposure risk; Matrix; Scattering; Dose rates; XRF;
D O I
10.1366/14-07809
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study investigates X-ray intensity and dispersion around handheld X-ray fluorescence (XRF) instruments during the measurement of a range of sample matrices to establish radiation exposure risk during operation. Four handheld XRF instruments representing three manufacturers were used on four smooth, flat-lying materials of contrasting matrix composition. Dose rates were measured at 10, 20, 30, and 40 cm intervals every 300 around the instrument at 0 and 450 from the horizontal, as well as vertically from the instrument screen. The analysis of polyethylene recorded dose rates 156 times higher (on average) than steel measurements and 34 times higher than both quartz sand and quartz sandstone. A worst-case exposure scenario was assumed where a user analyses a polyethylene material at arms reach for 1 h each working day for one year. This scenario resulted in an effective body dose of 73.5 mu Sv, equivalent to three to four chest X-rays (20 mu Sv) a year, 20 times lower than the average annual background radiation exposure in Australia and well below the annual exposure limit of 1 mSv for non-radiation workers. This study finds the advantages of using handheld XRF spectrometers far outweighs the risk of low radiation exposure linked to X-ray scattering from samples.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 50 条
  • [41] The ARL 9400 XP and XP+ sequential X-ray fluorescence spectrometers
    不详
    ZKG INTERNATIONAL, 1999, 52 (03): : A8 - +
  • [42] Total reflection X-ray fluorescence spectrometers for multielement analysis:: status of equipment
    Jiménez, REA
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2331 - 2336
  • [43] Development and application of portable, hand-held X-ray fluorescence spectrometers
    Bosco, Gerra L.
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 45 : 121 - 134
  • [44] MEASUREMENT OF SYNCHROTRON RADIATION IN X-RAY REGION
    BATHOW, G
    FREYTAG, E
    HAENSEL, R
    JOURNAL OF APPLIED PHYSICS, 1966, 37 (09) : 3449 - &
  • [45] Matrix Effect Corrections in X-ray Fluorescence Spectrometry
    Bowers, Chris
    JOURNAL OF CHEMICAL EDUCATION, 2019, 96 (11) : 2597 - 2599
  • [46] Characterization of the advantages and limitations of the use of handheld x-ray fluorescence for the analysis of ceramics
    Munro, Hannah
    Hornak, Jonathon
    Deibel, Corinne
    Deibel, Michael
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [47] Recycled Aggregate Mortar Content and Composition Using Handheld X-Ray Fluorescence
    Dey, Arindam
    Cavalline, Tara L.
    Mamirov, Miras
    Hu, Jiong
    ACI MATERIALS JOURNAL, 2023, 120 (05)
  • [48] Analysis of Cosmetic Mineral Eyeshadows and Foundations with a Handheld X-ray Fluorescence Analyzer
    Ngo, Tiffany Tieu
    Thomas, Sara
    Stokers, Diamond
    Benvenuto, Mark A.
    Roberts-Kirchhoff, Elizabeth S.
    ENVIRONMENTAL CHEMISTRY: UNDERGRADUATE AND GRADUATE CLASSROOM, LABORATORY, AND LOCAL COMMUNITY LEARNING EXPERIENCES, 2018, 1276 : 89 - 103
  • [49] Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers
    Elshafiey, A. T.
    Chalmers, N. G.
    Pikuz, S. A.
    Shelkovenko, T. A.
    Hammer, D. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (08):
  • [50] Measurement of K series of X-ray fluorescence spectra of Ce and Gd by high energy X-ray from synchrotron radiation source
    Harada, Masaaki
    Shoji, Masahiko
    Kawata, Hiroshi
    Sakurai, Kenji
    BUNSEKI KAGAKU, 2006, 55 (06) : 433 - 439