Handheld X-ray Fluorescence Spectrometers: Radiation Exposure Risks of Matrix-Specific Measurement Scenarios

被引:6
|
作者
Rouillon, Marek [1 ]
Kristensen, Louise J. [1 ]
Gore, Damian B. [1 ]
机构
[1] Macquarie Univ, Fac Sci & Engn, Dept Environm Sci, Sydney, NSW 2109, Australia
关键词
Radiation; X-ray fluorescence; XRF; Handheld XRF; Exposure risk; Matrix; Scattering; Dose rates; XRF;
D O I
10.1366/14-07809
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This study investigates X-ray intensity and dispersion around handheld X-ray fluorescence (XRF) instruments during the measurement of a range of sample matrices to establish radiation exposure risk during operation. Four handheld XRF instruments representing three manufacturers were used on four smooth, flat-lying materials of contrasting matrix composition. Dose rates were measured at 10, 20, 30, and 40 cm intervals every 300 around the instrument at 0 and 450 from the horizontal, as well as vertically from the instrument screen. The analysis of polyethylene recorded dose rates 156 times higher (on average) than steel measurements and 34 times higher than both quartz sand and quartz sandstone. A worst-case exposure scenario was assumed where a user analyses a polyethylene material at arms reach for 1 h each working day for one year. This scenario resulted in an effective body dose of 73.5 mu Sv, equivalent to three to four chest X-rays (20 mu Sv) a year, 20 times lower than the average annual background radiation exposure in Australia and well below the annual exposure limit of 1 mSv for non-radiation workers. This study finds the advantages of using handheld XRF spectrometers far outweighs the risk of low radiation exposure linked to X-ray scattering from samples.
引用
收藏
页码:815 / 822
页数:8
相关论文
共 50 条
  • [1] Calcium and Phosphorus Detection Using Benchtop Versus Handheld X-ray Fluorescence Spectrometers
    Kuzel, Aaron R.
    Christensen, Angi M.
    Marvin, Susan M.
    JOURNAL OF FORENSIC SCIENCES, 2016, 61 : S190 - S192
  • [2] Validation of handheld X-ray fluorescence for in situ measurement of mercury in soils
    Brent, Robert N.
    Wines, Hunter
    Luther, Joseph
    Irving, Nathan
    Collins, Joshua
    Drake, Brandon L.
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2017, 5 (01): : 768 - 776
  • [3] Technical note: Application of Handheld X-ray fluorescence spectrometers in forensic analysis of cigarette ash
    Senra, Beatriz P.
    Ribeiro, Helena
    Guedes, Alexandra
    FORENSIC SCIENCE INTERNATIONAL, 2024, 361
  • [4] The potential of microcalorimeter X-ray spectrometers for measurement of relative fluorescence-line intensities
    Fowler, J. W.
    Miaja-Avila, L.
    O'Neil, G. C.
    Ullom, J. N.
    Whitelock, H.
    Swetz, D. S.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 202
  • [5] Handheld Portable X-Ray Fluorescence of Aegean Obsidians
    Frahm, E.
    Doonan, R.
    Kilikoglou, V.
    ARCHAEOMETRY, 2014, 56 (02) : 228 - 260
  • [6] Spectrometers for Elemental Spectrochemical Analysis, Part II: X-Ray Fluorescence Spectrometers
    Thomsen, Volker
    Coutinho, Carlos Augusto
    SPECTROSCOPY, 2010, 25 (07) : 38 - 43
  • [7] Effect of the sample matrix on measurement uncertainty in X-ray fluorescence analysis
    Morgenstern, P
    Brüggemann, L
    Wennrich, R
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (9-10) : 1373 - 1379
  • [8] EFFECT OF DISTANCE BETWEEN X-RAY TUBE AND SAMPLE ON SENSITIVITY OF FLUORESCENCE X-RAY SPECTROMETERS
    NIKOLSKI.AP
    KORDONSK.GA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1965, (03): : 659 - &
  • [9] X-RAY EXPOSURE AND RADIATION PROTECTION IN X-RAY DIAGNOSTICS
    SCHMIDT, T
    ATOMKERNENERGIE, 1973, 22 (02): : 129 - 133
  • [10] Analysis of mineral cosmetics with a handheld X-ray fluorescence analyzer
    Thomas, Sara
    Nguyen, Grace
    Stokes, Diamond
    Ngo, Tiffany Tieu
    Benvenuto, Mark
    Roberts-Kirchhoff, Elizabeth
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253