Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging

被引:18
|
作者
Schleipman, A. Robert
Castronovo, Frank P., Jr.
Di Carli, Marcelo F.
Dorbala, Sharmila
机构
[1] Brigham & Womens Hosp, Div Hlth Phys, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Div Radiopharmacol, Boston, MA USA
[3] Brigham & Womens Hosp, Div Nucl Med, Boston, MA USA
[4] Brigham & Womens Hosp, Div Cardiovasc Imaging, Boston, MA USA
[5] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
myocardial perfusion imaging; positron emission tomography; rubidium; 82; radiation dose; exercise stress testing;
D O I
10.1016/j.nuclcard.2006.03.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We determined staff radiation dose during rest and stress rubidium 82 myocardial perfusion positron emission tomography (PET) imaging. Methods and Results. Patients received 1587 +/- 163 MBq (42.9 +/- 4.4 mCi) Rb-82 during rest or pharmacologic stress. A pressurized ion chamber was used to monitor radiation exposure in 50 examinations. For comparison, staff exposure during pharmacologic stress in 20 other patients receiving 1204 +/- 55.5 MBq (32.54 +/- 1.5 mCi) technetium 99m 2-methoxy isobutyl isonitrile (MIBI) was measured. For Rb-82 infusion and PET acquisition, the mean dose was 0.45 +/- 0.25 mu Sv (0.045 +/- 0.025 mrem). Exposure for routine stress testing at variable distances from the patient was equivalent to background. Similar exposure for pharmacologic stress testing through 7 minutes after injection of Tc-99m MIBI at variable distances was 1.075 +/- 0.32 mu Sv (0.108 +/- 0.03 mrem). However, exposure for stress tests starting 7 minutes after Rb-82 infusion at 0.5 m was estimated at 0.4 mu Sv (0.04 mrem). To determine the potential radiation dose for those responding to a medical emergency or otherwise in close proximity to a patient, we measured the mean cumulative dose at 0.5 m from 0 to 7 minutes of Rb-82 infusion, which resulted in 19.1 +/- 5.8 mu Sv (1.9 +/- 0.58 mrem). Conclusions. Radiation doses for all tasks during routine Rb-82 stress-rest PET are lower than measured Tc-99m MIBI values. However, the radiation dose in close proximity to the patient during or immediately after Rb-82 infusion can be considerably higher, underscoring the need for strict attention to source distance and contact times.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 50 条
  • [21] SERIAL ASSESSMENT OF RENAL PERFUSION IN EXPERIMENTAL RENOVASCULAR HYPERTENSION BY POSITRON TOMOGRAPHY WITH RB-82
    TAMAKI, N
    RABITO, CA
    ALPERT, NM
    KANKE, M
    YASUDA, T
    STRAUSS, HW
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (02) : A113 - A113
  • [22] SPECTAttenuation artifacts in normal and overweight persons - Insights from a retrospective comparison of Rb-82 positron emission tomography and Tl-201SPECT myocardial perfusion imaging
    Freedman, N
    Schechter, D
    Klein, M
    Marciano, R
    Rozenman, Y
    Chisin, R
    CLINICAL NUCLEAR MEDICINE, 2000, 25 (12) : 1019 - 1023
  • [23] Ability of PET Rb-82 myocardial perfusion imaging to predict death.
    Tallet, J
    Eisner, RL
    Mansour, CS
    Patterson, RE
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 2P - 2P
  • [24] NONINVASIVE DETECTION OF CORONARY COLLATERALS USING DIPYRIDAMOLE RB-82 POSITRON EMISSION TOMOGRAPHY
    GARZA, D
    VANTOSH, A
    ROBERTI, R
    REIMERS, C
    FOX, J
    HOROWITZ, SF
    CLINICAL RESEARCH, 1994, 42 (02): : A159 - A159
  • [25] Feasibility of exercise rubidium-82 positron emission tomography myocardial perfusion imaging
    Chow, BJ
    Ruddy, TD
    Dalipaj, MM
    de Kemp, RA
    Nadeau, C
    Ukkonen, H
    Ananthasubramaniam, K
    Beanlands, RS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 428A - 428A
  • [26] AN AUTOMATED MICROPROCESSOR-CONTROLLED RB-82 GENERATOR FOR POSITRON EMISSION TOMOGRAPHY STUDIES
    YANO, Y
    BUDINGER, TF
    CAHOON, JL
    HUESMAN, RH
    ACS SYMPOSIUM SERIES, 1984, 241 : 97 - 122
  • [27] SERIAL ANALYSIS OF RENAL BLOOD-FLOW BY POSITRON EMISSION TOMOGRAPHY WITH RB-82
    TAMAKI, N
    RABITO, CA
    ALPERT, NM
    KANKE, M
    YASUDA, T
    BARLAIKOVACH, M
    NEDELMAN, MA
    CORREIA, JA
    STRAUSS, HW
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 941 - 941
  • [28] Prognosis of a Normal Positron Emission Tomography 82Rb Myocardial Perfusion Imaging Study in Women with No History of Coronary Disease
    Van Tosh, Andrew
    Supino, Phyllis G.
    Nichols, Kenneth J.
    Garza, Dahlia
    Horowitz, Steven F.
    Reichek, Nathaniel
    CARDIOLOGY, 2010, 117 (04) : 301 - 306
  • [29] Influence of dose, mode and patient size in Rb-82 myocardial PET imaging
    Knesaurek, K
    Machac, J
    Krynyckyi, BR
    Almeida, OD
    Kim, CK
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 211P - 212P
  • [30] MYOCARDIAL POSITRON SCINTIGRAPHY WITH SHORT-LIVED RB-82
    HOOP, B
    BEH, RA
    BELLER, GA
    BROWNELL, GL
    BURNHAM, CA
    HNATOWICH, DJ
    MOORE, RH
    PARKER, JA
    ROUXLOUGH, PO
    SMITH, TW
    BUDINGER, TF
    CHU, P
    YANO, Y
    BARNES, JW
    GRANT, PM
    OGARD, AE
    OBRIEN, HA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 584 - 589