Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging

被引:18
|
作者
Schleipman, A. Robert
Castronovo, Frank P., Jr.
Di Carli, Marcelo F.
Dorbala, Sharmila
机构
[1] Brigham & Womens Hosp, Div Hlth Phys, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Div Radiopharmacol, Boston, MA USA
[3] Brigham & Womens Hosp, Div Nucl Med, Boston, MA USA
[4] Brigham & Womens Hosp, Div Cardiovasc Imaging, Boston, MA USA
[5] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
关键词
myocardial perfusion imaging; positron emission tomography; rubidium; 82; radiation dose; exercise stress testing;
D O I
10.1016/j.nuclcard.2006.03.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We determined staff radiation dose during rest and stress rubidium 82 myocardial perfusion positron emission tomography (PET) imaging. Methods and Results. Patients received 1587 +/- 163 MBq (42.9 +/- 4.4 mCi) Rb-82 during rest or pharmacologic stress. A pressurized ion chamber was used to monitor radiation exposure in 50 examinations. For comparison, staff exposure during pharmacologic stress in 20 other patients receiving 1204 +/- 55.5 MBq (32.54 +/- 1.5 mCi) technetium 99m 2-methoxy isobutyl isonitrile (MIBI) was measured. For Rb-82 infusion and PET acquisition, the mean dose was 0.45 +/- 0.25 mu Sv (0.045 +/- 0.025 mrem). Exposure for routine stress testing at variable distances from the patient was equivalent to background. Similar exposure for pharmacologic stress testing through 7 minutes after injection of Tc-99m MIBI at variable distances was 1.075 +/- 0.32 mu Sv (0.108 +/- 0.03 mrem). However, exposure for stress tests starting 7 minutes after Rb-82 infusion at 0.5 m was estimated at 0.4 mu Sv (0.04 mrem). To determine the potential radiation dose for those responding to a medical emergency or otherwise in close proximity to a patient, we measured the mean cumulative dose at 0.5 m from 0 to 7 minutes of Rb-82 infusion, which resulted in 19.1 +/- 5.8 mu Sv (1.9 +/- 0.58 mrem). Conclusions. Radiation doses for all tasks during routine Rb-82 stress-rest PET are lower than measured Tc-99m MIBI values. However, the radiation dose in close proximity to the patient during or immediately after Rb-82 infusion can be considerably higher, underscoring the need for strict attention to source distance and contact times.
引用
收藏
页码:378 / 384
页数:7
相关论文
共 50 条
  • [1] Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging
    A. Robert Schleipman
    Frank P. Castronovo
    Marcelo F. Di Carli
    Sharmila Dorbala
    Journal of Nuclear Cardiology, 2006, 13 : 378 - 384
  • [2] Occupational radiation dose associated with Rb-82 myocardial perfusion positron emission tomography imaging (vol 13, pg 378, 2006)
    Schleipman, A. R.
    Castronovo, F. P., Jr.
    Di Carli, M. F.
    Dorbala, S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (04) : 600 - 600
  • [3] Prognostic value of Rb-82 positron emission tomography myocardial perfusion imaging in coronary artery bypass patients
    Pen, Ally
    Yam, Yeung
    Chen, Li
    Dorbala, Sharmila
    Di Carli, Marcelo F.
    Merhige, Michael E.
    Williams, Brent A.
    Veladar, Emir
    Min, James K.
    Pencina, Michael J.
    Berman, Daniel S.
    Beanlands, Rob S.
    Shaw, Leslee J.
    Chow, Benjamin J. W.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (07) : 787 - 792
  • [4] Prognostic significance of blood pressure response during vasodilator stress Rb-82 positron emission tomography myocardial perfusion imaging
    Witbrodt, Bradley
    Goyal, Abhinav
    Kelkar, Anita A.
    Dorbala, Sharmila
    Chow, Benjamin J. W.
    Di Carli, Marcelo F.
    Williams, Brent A.
    Merhige, Michael E.
    Berman, Daniel S.
    Germano, Guido
    Beanlands, Robert S.
    Min, James K.
    Arasaratnam, Punitha
    Sadreddini, Masoud
    van Velthuijsen, Marjolein Lidwine
    Shaw, Leslee J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (06) : 1966 - 1975
  • [5] Prognostic significance of blood pressure response during vasodilator stress Rb-82 positron emission tomography myocardial perfusion imaging
    Bradley Witbrodt
    Abhinav Goyal
    Anita A. Kelkar
    Sharmila Dorbala
    Benjamin J. W. Chow
    Marcelo F. Di Carli
    Brent A. Williams
    Michael E. Merhige
    Daniel S. Berman
    Guido Germano
    Robert S. Beanlands
    James K. Min
    Punitha Arasaratnam
    Masoud Sadreddini
    Marjolein Lidwine van Velthuijsen
    Leslee J. Shaw
    Journal of Nuclear Cardiology, 2017, 24 : 1966 - 1975
  • [6] MYOCARDIAL EXTRACTION OF RB-82 VS FLOW DETERMINED BY POSITRON EMISSION TOMOGRAPHY
    BUDINGER, TF
    YANO, Y
    MOYER, B
    TWITCHELL, J
    HUESMAN, RH
    CIRCULATION, 1983, 68 (04) : 81 - 81
  • [7] Characterization of a Rb-82 Generator for Positron Emission Tomography
    Chudakov, V. M.
    Zhuikov, B. L.
    Ermolaev, S. V.
    Kokhanyuk, V. M.
    Mostova, M. I.
    Zaitsev, V. V.
    Shatik, S. V.
    Kostenikov, N. A.
    Ryzhkova, D. V.
    Tyutin, L. A.
    RADIOCHEMISTRY, 2014, 56 (05) : 535 - 543
  • [8] IMPLEMENTATION AND EVALUATION OF A 2-COMPARTMENT MODEL FOR QUANTIFICATION OF MYOCARDIAL PERFUSION WITH RB-82 AND POSITRON EMISSION TOMOGRAPHY
    HERRERO, P
    MARKHAM, J
    SHELTON, ME
    BERGMANN, SR
    CIRCULATION RESEARCH, 1992, 70 (03) : 496 - 507
  • [9] IMPLEMENTATION OF A 2-COMPARTMENT MODEL FOR QUANTIFICATION OF MYOCARDIAL PERFUSION WITH RB-82 AND POSITRON EMISSION TOMOGRAPHY (PET)
    HERRERO, P
    MARKHAM, J
    SHELTON, ME
    BERGMANN, SR
    CIRCULATION, 1990, 82 (04) : 478 - 478
  • [10] NONINVASIVE QUANTIFICATION OF REGIONAL MYOCARDIAL PERFUSION WITH RB-82 AND POSITRON EMISSION TOMOGRAPHY - EXPLORATION OF A MATHEMATICAL-MODEL
    HERRERO, P
    MARKHAM, J
    SHELTON, ME
    WEINHEIMER, CJ
    BERGMANN, SR
    CIRCULATION, 1990, 82 (04) : 1377 - 1386