Glow Discharge Mass Spectrometry for Cobalt Alloys Analysis

被引:0
|
作者
Itoh, Shinji [1 ]
Yamada, Katsura [1 ]
Kobayashi, Takeshi [1 ]
机构
[1] Natl Inst Mat Sci, Mat Anal Stn, Tsukuba, Ibaraki 3050047, Japan
关键词
relative sensitivity factor; cobalt alloys; glow discharge mass spectrometry; fundamental parameter/X-ray fluorescence spectrometry;
D O I
10.2116/bunsekikagaku.58.27
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A comparison of results obtained using argon/glow discharge mass spectrometry (Ar/GD-MS) and fundamental parameter/X-ray fluorescence analysis (FP/XRF) was made by analyzing of cobalt (Co) alloys. The relative sensitivity factors (RSF) used for GD-MS quantitative analysis were determined using six commercial Co alloy standard reference materials. The analysis objects comprised 16 elements contained in Co alloys: C, Al, Si, P, S, Ti, Cr, Mn, Fe, Ni, Cu, Nb, Mo, Sn, La, and W. A glow-discharge cell for disk samples was used. A sample mask made from Ta, a part of the anode, was employed; it had an internal diameter of 12 mm. The discharge parameters were 1 kV and 3 mA. Samples were put on a liquid sample CLIP with an adherent 6.3-mu m-thick polypropylene film and subjected to a FP/XRF measurement. The sensitivity coefficients (K(ij)) of XRF for Co alloys were determined through measuring identical standard substances, such as GD-MS, and processing thereof using UQ5 software. A commercial Co alloy, Haynes 188, was subjected to chemical analysis; the GD-MS, chemical analysis, and FP/XRF results were compared. The FP/XRF results of the main components (Cr, Fe, Ni, and W) agreed well with the GD-MS and chemical analysis results. The analytical accuracy was satisfactory as 0.18% (Cr) similar to 0.46% (W) in RSD. However, some overestimation occurred for minor, elements such as Cu and La, at low concentrations, where RSD was 10 similar to 17%. On the other hand, the GD-MS results agreed well with results of chemical analysis obtained from P and S at the trace impurity level, minor components, to main components. The analytical accuracy of GD-MS was shown to be within 2% as RSD for most elements, from main components, such as Cr (RSD : 1.2%), Ni (1.0%), and W (0.89%), to elements of trace impurity level, like S (4.5%), including minor components.
引用
收藏
页码:27 / 31
页数:5
相关论文
共 50 条
  • [31] Determination of elemental composition of Zr-Nb alloys by glow discharge quadrupole mass spectrometry
    Shekhar, R
    Arunachalam, J
    Krishna, GR
    Ravindra, HR
    Gopalan, B
    ATOMIC SPECTROSCOPY, 2004, 25 (04) : 157 - 164
  • [32] Compositions of Co-Cr-Mo alloys examined by glow-discharge mass spectrometry
    Kurochkin, VD
    POWDER METALLURGY AND METAL CERAMICS, 2004, 43 (7-8) : 411 - 416
  • [33] ANALYSIS OF ALUMINUM-ALLOYS USING INDUCTIVELY-COUPLED PLASMA AND GLOW-DISCHARGE MASS-SPECTROMETRY
    FENG, XB
    HORLICK, G
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (08) : 823 - 831
  • [34] Determination of oxygen in magnesium by glow discharge mass spectrometry
    Kikuta, Emi
    Asano, Hiloshi
    Kikuchi, Tadashi
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2007, 93 (02): : 128 - 131
  • [35] Mass spectrometry of molecules and radicals in glow discharge plasma
    Belikov, A. E.
    Sakhapov, S. Z.
    Smith, M. A.
    Tikhonov, G.
    JOURNAL OF ENGINEERING THERMOPHYSICS, 2011, 20 (01) : 42 - 54
  • [36] Elemental analysis of Fe-based powders by glow discharge mass spectrometry
    Inoue, M
    Saka, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1998, 84 (04): : 261 - 266
  • [37] Depth Profile Analysis of Molybdenum Disulfide Film by Glow Discharge Mass Spectrometry
    Wang, Mengli
    Zhao, Bin
    Zhuo, Shangjun
    Zhu, Yueqin
    Huang, Lei
    Qian, Rong
    ATOMIC SPECTROSCOPY, 2021, 42 (04) : 183 - 189
  • [38] The Analysis of High purity Silicon wafers using Glow Discharge Mass Spectrometry
    Milton, D. M. P.
    Clark, J.
    Potter, D.
    Hutton, R. C.
    ANALYTICAL SCIENCES, 1991, 7 : 1243 - 1246
  • [39] Detection of negative ions in glow discharge mass spectrometry for analysis of solid specimens
    Stela Canulescu
    Igor S. Molchan
    C. Tauziede
    Agnes Tempez
    J. A. Whitby
    George E. Thompson
    Peter Skeldon
    P. Chapon
    Johann Michler
    Analytical and Bioanalytical Chemistry, 2010, 396 : 2871 - 2879
  • [40] GLOW-DISCHARGE MASS-SPECTROMETRY - A VERSATILE TOOL FOR ELEMENTAL ANALYSIS
    STUEWER, D
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (07): : 737 - 742