A Three-Phase Unbalanced Line Model with Grounded Neutrals through a Resistance

被引:0
|
作者
Kersting, W. H.
机构
关键词
Distribution systems; modeling; analysis; power-flow studies; short-circuit studies;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Distribution Analysis power-flow and short-circuit studies typically model overhead and underground lines assuming that the neutrals are solidly grounded. That assumption has come under question since grounded wye lines will not actually have zero resistance between the neutral conduction and ground. Without a solid ground there will be a voltage between the neutral and ground. In order to determine the voltage under typical operating conditions a model for the grounded wye lines must be developed. The purpose of this paper is to present the data for a simple three-phase overhead line that is grounded at regular intervals through a resistance. Companion papers will use this data to develop models that can be used in power-flow and short-circuit studies. The final result will be a "standard" line model that will include the grounded neutrals through a resistance.
引用
收藏
页码:2651 / 2652
页数:2
相关论文
共 50 条
  • [21] A Fast Estimation Method for Unbalanced Three-Phase Systems
    Galeshi, Soleiman
    Iman-Eini, Hosein
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 383 - 388
  • [22] An asymmetrical power measurement in an unbalanced three-phase system
    Graczyk, Adam
    Kusmierek, Zygmunt
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (09): : 23 - 26
  • [23] Effect of the Neutral Interruption on the Unbalanced Three-Phase Consumers
    Lepadat, Ionel
    Helerea, Elena
    Abagiu, Sorin
    2014 INTERNATIONAL CONFERENCE ON OPTIMIZATION OF ELECTRICAL AND ELECTRONIC EQUIPMENT (OPTIM), 2014, : 192 - 197
  • [24] Three-phase SEPIC PFC for three-phase IM drive under unbalanced and distorted voltage supply
    Al-Gahtani, Saad F.
    Azazi, Haitham Z.
    Elbarbary, Z. M. Salem
    ELECTRICAL ENGINEERING, 2021, 103 (01) : 357 - 371
  • [25] Three-phase SEPIC PFC for three-phase IM drive under unbalanced and distorted voltage supply
    Saad F. Al-Gahtani
    Haitham Z. Azazi
    Z. M. Salem Elbarbary
    Electrical Engineering, 2021, 103 : 357 - 371
  • [26] Methods for Stability Analysis of Unbalanced Three-Phase Systems
    Cespedes, Mauricio
    Sun, Jian
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 3090 - 3097
  • [27] An Adaptive Parameter Estimator for Unbalanced Three-Phase System
    Chen, Yuan
    Huang, Long-Ting
    Sun, Weize
    So, H. C.
    2017 22ND INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING (DSP), 2017,
  • [28] Accurate Parameter Estimation for Unbalanced Three-Phase System
    Chen, Yuan
    So, Hing Cheung
    SCIENTIFIC WORLD JOURNAL, 2014,
  • [29] Evaluation of the losses in unbalanced three-phase power systems
    Caramia, P
    Verde, P
    Menniti, D
    MELECON '96 - 8TH MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, PROCEEDINGS, VOLS I-III: INDUSTRIAL APPLICATIONS IN POWER SYSTEMS, COMPUTER SCIENCE AND TELECOMMUNICATIONS, 1996, : 715 - 720
  • [30] A novel PLL for unbalanced three-phase grid voltage
    Wang, Lujun (wanglujun@zju.edu.cn), 1600, Science Press (35):