Micro-computed Tomography Study of Oval-shaped Canals Prepared with the Self-adjusting File, Reciproc, WaveOne, and ProTaper Universal Systems

被引:126
|
作者
Versiani, Marco Aurelio [1 ]
Leoni, Graziela Bianchi [1 ]
Steien, Liviu [2 ]
De-Deus, Gustavo [3 ]
Tassani, Simone [4 ]
Pecora, Jesus Djalma [1 ]
de Sousa-Neto, Manoel Damiao [1 ]
机构
[1] Univ Sao Paulo, Dept Restorat Dent, Dent Sch Ribeirao Preto, Sao Paulo, Brazil
[2] Univ Warwick, Coventry CV4 7AL, W Midlands, England
[3] Unigranrio, Sch Dent, Rio De Janeiro, Brazil
[4] Natl Tech Univ Athens, Inst Commun & Comp Syst, Athens, Greece
基金
巴西圣保罗研究基金会;
关键词
Micro-computed tomography; nickel-titanium instruments; reciprocating motion; root canal preparation; self-adjusting file; CURVED ROOT CANALS; SINGLE-FILE; SHAPING ABILITY; DEBRIDEMENT QUALITY; ROTARY; MOLARS; TEETH; INSTRUMENT; DEBRIS;
D O I
10.1016/j.joen.2013.04.009
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The newly developed single-file systems claimed to be able to prepare the root canal space with only 1 instrument. The present study was designed to test the null hypothesis that there is no significant difference in the preparation of oval-shaped root canals using single- or multiple-file systems. Methods: Seventy-two single-rooted mandibular canines were matched based on similar morphologic dimensions of the root canal achieved in a micro-computed tomographic evaluation and assigned to 1 of 4 experimental groups (n = 18) according to the preparation technique (ie, Self-Adjusting File [ReDent-Nova, Ra'anana, Israel], WaveOne [Dentsply Maillefer, Ballaigues, Switzerland], Reciproc [VDW, Munich, Germany], and ProTaper Universal [Dentsply Maillefer] systems). Changes in the 2- and 3-dimensional geometric parameters were compared with preoperative values using analysis of variance and the post hoc Tukey test between groups and the paired sample t test within groups (alpha = 0.05). Results: Preparation significantly increased the analyzed parameters; the outline of the canals was larger and showed a smooth taper in all groups. Untouched areas occurred mainly on the lingual side of the middle third of the canal. Overall, a comparison between groups revealed that SAF presented the lowest, whereas WaveOne and ProTaper Universal showed the highest mean increase in most of the analyzed parameters (P < .05). Conclusions: All systems performed similarly in terms of the amount of touched dentin walls. Neither technique was capable of completely preparing the oval-shaped root canals.
引用
收藏
页码:1060 / 1066
页数:7
相关论文
共 50 条
  • [21] Self-Adjusting File Cleaning-Shaping-Irrigation System Optimizes the Filling of Oval-shaped Canals with Thermoplasticized Gutta-percha
    De-Deus, Gustavo
    Burino, Bianca
    Marins, Juliana
    Magalhaes, Karen
    Thuanne, Erika
    Kfir, Anda
    JOURNAL OF ENDODONTICS, 2012, 38 (06) : 846 - 849
  • [22] The Challenge of C-shaped Canal Systems: A Comparative Study of the Self-Adjusting File and ProTaper
    Solomonov, Michael
    Paque, Frank
    Fan, Bing
    Eilat, Yuval
    Berman, Louis H.
    JOURNAL OF ENDODONTICS, 2012, 38 (02) : 209 - 214
  • [23] Removal of Filling Materials from Oval-shaped Canals Using Laser Irradiation: A Micro-computed Tomographic Study
    Keles, Ali
    Arslan, Hakan
    Kamalak, Aliye
    Akcay, Merve
    Sousa-Neto, Manoel D.
    Versiani, Marco Aurelio
    JOURNAL OF ENDODONTICS, 2015, 41 (02) : 219 - 224
  • [24] Preparation of Oval-shaped Root Canals in Mandibular Molars Using Nickel-Titanium Rotary Instruments: A Micro-computed Tomography Study
    Paque, Frank
    Balmer, Marc
    Attin, Thomas
    Peters, Ove A.
    JOURNAL OF ENDODONTICS, 2010, 36 (04) : 703 - 707
  • [25] Efficacy of ProTaper Universal Rotary Retreatment System for Gutta-percha Removal from Oval Root Canals: A Micro-Computed Tomography Study
    Ma, Jingzhi
    Al-Ashaw, Ahmed Jawad
    Shen, Ya
    Gao, Yuan
    Yang, Yan
    Zhang, Chengfei
    Haapasalo, Markus
    JOURNAL OF ENDODONTICS, 2012, 38 (11) : 1516 - 1520
  • [26] Retreatment of flat-oval root canals with a self-adjusting file: An SEM study
    Keles, Ali
    Simsek, Neslihan
    Alcin, Hatice
    Ahmetoglu, Fuat
    Yologlu, Saim
    DENTAL MATERIALS JOURNAL, 2014, 33 (06) : 786 - 791
  • [27] Comparison of the Self-Adjusting File with Rotary and Hand Instrumentation in Long-oval-shaped Root Canals
    Ruckman, Jim E.
    Whitten, Brian
    Sedgley, Christine M.
    Svec, Timothy
    JOURNAL OF ENDODONTICS, 2013, 39 (01) : 92 - 95
  • [28] Comparison of Obturation Removal Efficiency from Straight Root Canals with ProTaper Gold or Reciproc Blue: A Micro-Computed Tomography Study
    Faus-Matoses, Vicente
    Pasarin-Linares, Cristina
    Faus-Matoses, Ignacio
    Foschi, Federico
    Sauro, Salvatore
    Faus-Llacer, Vicente J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (04)
  • [29] Comparison of newly formed microcracks after instrumentation using Protaper Next, Reciproc and Self-Adjusting File systems
    Cakici, Fatih
    Cakici, Elif Bahar
    Sadik, Burak
    Keles, Ali
    Kucukekenci, Funda Fundaoglu
    EUROPEAN ORAL RESEARCH, 2019, 53 (01) : 21 - 24
  • [30] Self-Adjusting Files in Retreatment: A High-resolution Micro-Computed Tomography Study
    Solomonov, Michael
    Paque, Frank
    Kaya, Sadullah
    Adzguzel, Ozkan
    Kfir, Anda
    Yigit-Ozer, Senem
    JOURNAL OF ENDODONTICS, 2012, 38 (09) : 1283 - 1287