Investigation of a small-diameter decellularised artery as a potential scaffold for vascular tissue engineering; biomechanical evaluation and preliminary cell seeding

被引:32
|
作者
Campbell, E. M. [1 ]
Cahill, P. A. [2 ]
Lally, C. [1 ]
机构
[1] Dublin City Univ, Sch Mech & Mfg Engn, Dublin 9, Ireland
[2] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
基金
爱尔兰科学基金会;
关键词
Tissue engineering; Vascular scaffold; Decellularised artery; Biomechanics; MECHANICAL-PROPERTIES; BLOOD-VESSELS; CAROTID ARTERIES; EX-VIVO; PORCINE; MATRICES; GRAFTS; BEHAVIOR; VEIN;
D O I
10.1016/j.jmbbm.2012.06.001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The development of a small-diameter tissue engineered blood vessel (TEBV), with equivalent mechanical properties to the vessel being replaced, may provide a potential solution to the limitations associated with natural and synthetic bypass grafts of small-diameter vessels. This study presents the biomechanical properties of small-diameter (<4 mm) porcine coronary arteries (PCA) and the corresponding natural matrix scaffold of the artery achieved through short-term decellularisation. Tubular segments, up to 50 mm in length, of PCA were perfused with 0.1 M sodium hydroxide (NaOH) for 3 to 12 h to achieve the natural matrix scaffold. Uniaxial tensile, inflation and permeability tests were performed on non-decellularised and decellularised sections within 24 h of slaughter to determine the alteration in mechanical properties as a result of decellularisation. A treatment time of 9 h achieved decellularisation as all cell nuclei were appropriately disrupted and there was an absence of smooth muscle in the vascular wall. Uniaxial tensile and inflation tests confirmed the scaffold maintains its non-linear response, however a less stiff, more distensible low-load response and stiffer high-load response was found compared to non-decellularised sections. Vascular smooth muscle cells were successfully seeded to the lumen, abluminal side and lateral edges of decellularised sections and attachment and infiltration of the xenogeneic cells after 15 days confirmed the viability of the PCA scaffold as a suitable environment for cell growth and infiltration. An extended decellularisation treatment time increased the porosity whilst maintaining the mechanical integrity of the scaffold and this may optimise the repopulation of the scaffold. This study provides valuable information for the development of an optimum TEBV, while also establishing the potential of this natural matrix scaffold to be used as a graft or vascular tissue engineering scaffold. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:130 / 142
页数:13
相关论文
共 50 条
  • [31] Vascular Damage and Repair- Are Small-Diameter Vascular Grafts Still the "Holy Grail" of Tissue Engineering?
    Bacakova, Lucie
    Chlupac, Jaroslav
    Filova, Elena
    Musilkova, Jana
    Tomsu, Julia
    Wu, Yu-Chieh
    Svobodova, Lucie
    Prazak, Simon
    Broz, Antonin
    PHYSIOLOGICAL RESEARCH, 2024, 73 : S335 - S363
  • [32] Tissue engineering of small-diameter arteries using human adipose stem cells on an electrospun scaffold.
    Dhanasopon, A. P.
    Hagvall, S. H.
    Beygui, R. E.
    Samueli, H.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2007, 55 (01) : S154 - S154
  • [33] Development and Validation of Small-diameter Vascular Tissue From a Decellularized Scaffold Coated With Heparin and Vascular Endothelial Growth Factor
    Zhou, Min
    Liu, Zhao
    Wei, Zhiqing
    Liu, Changjian
    Qiao, Tong
    Ran, Feng
    Bai, Yan
    Jiang, Xuefeng
    Ding, Ying
    ARTIFICIAL ORGANS, 2009, 33 (03) : 230 - 239
  • [34] Mesenchymal stem cell-based tissue engineering of small-diameter blood vessels
    Dong, Jian-De
    Huang, Jin-Hong
    Gao, Feng
    Zhu, Zhao-Hui
    Zhang, Jian
    VASCULAR, 2011, 19 (04) : 206 - 213
  • [35] Evaluation of a xenogeneic acellular collagen matrix as a small-diameter vascular graft in dogs - Preliminary observations
    Nemcova, S
    Noel, AA
    Jost, CJ
    Gloviczki, P
    Miller, VM
    Brockbank, KGM
    JOURNAL OF INVESTIGATIVE SURGERY, 2001, 14 (06) : 321 - 330
  • [36] Electrostatic endothelial cell seeding technique for small-diameter (&lt;6 mm) vascular prostheses:: Feasibility testing
    Bowlin, GL
    Rittgers, SE
    CELL TRANSPLANTATION, 1997, 6 (06) : 623 - 629
  • [37] In vivo regeneration of small-diameter arteries using a novel tissue-engineered biodegradable vascular graft without ex vivo cell seeding
    Yokota, Takenori
    Ichikawa, Hajime
    Matsumiya, Gorou
    Torikai, Kei
    Kitabayasi, Katsukiyo
    Hirakawa, Kouichirou
    Sawa, Yoshiki
    CIRCULATION, 2006, 114 (18) : 34 - 34
  • [38] A Potential Nonthrombogenic Small-Diameter Vascular Scaffold with Polyurethane/Poly(ethylene glycol) Hybrid Materials by Electrospinning Technique
    Wang, Heyun
    Feng, Yakai
    Zhao, Haiyang
    Fang, Zichen
    Khan, Musammir
    Guo, Jintang
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (02) : 1578 - 1582
  • [39] Preliminary Investigation of Seeding Mesenchymal Stem Cells on Biodegradable Scaffolds for Vascular Tissue Engineering In Vitro
    Li, Chun-Min
    Wang, Zhong-Gao
    Gu, Yong-Quan
    Dong, Jian-De
    Qiu, Rong-Xin
    Bian, Ce
    Liu, Xiao-Fei
    Feng, Zeng-Guo
    ASAIO JOURNAL, 2009, 55 (06) : 614 - 619
  • [40] Small-Diameter Vessels Reconstruction Using Cell Tissue-Engineering Graft Based on the Polycaprolactone
    Yudintceva N.M.
    Nashchekina Y.A.
    Shevtsov M.A.
    Karpovich V.B.
    Popov G.I.
    Samusenko I.A.
    Mikhailova N.A.
    Cell and Tissue Biology, 2021, 15 (6) : 577 - 585