Cholinesterase biosensor construction - A review

被引:29
|
作者
Pohanka, Miroslav [2 ]
Jun, Daniel [1 ,3 ]
Kalasz, Huba [4 ,5 ]
Kuca, Kamil [1 ,3 ,6 ]
机构
[1] Univ Def, Ctr Adv Studies, Fac Mil Med, Hradec Kralove, Czech Republic
[2] Cent Mil Inst Hlth, Ctr Biol Def, Techonin, Czech Republic
[3] Univ Def, Dept Toxicol, Fac Mil Med, Hradec Kralove, Czech Republic
[4] Semmelweis Univ, Dept Pharmacodynam, H-1085 Budapest, Hungary
[5] UAE Univ, Dept Pharmacol & Therapeut, FMHS, Al Ain, U Arab Emirates
[6] Univ JE Purkyne, Dept Chem, Fac Sci, Usti Nad Labem, Czech Republic
来源
PROTEIN AND PEPTIDE LETTERS | 2008年 / 15卷 / 08期
关键词
cholinesterase; immobilization; biosensor; carbamate; organophosphate; pesticide;
D O I
10.2174/092986608785203665
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Biosensors using cholinesterases as the biorecognition component have been used to assay organophosphates and carbamates for a long time. In this review, some strategies convenient for biosensor construction are presented. Solutions for cholinesterase immobilization and output signal monitoring are presented as the basic presumptions for successful biosensor construction.
引用
收藏
页码:795 / 798
页数:4
相关论文
共 50 条
  • [1] Cholinesterase Biosensor for Detection of Nerve Agents
    Vymazalova, K.
    Halamek, E.
    Kadlcak, J.
    [J]. CHEMICKE LISTY, 2016, 110 (09): : 645 - 650
  • [2] A Review of the Construction of the Nanomaterial & Nanocomposite Based Biosensor forDifferent Applications
    Munshe, Fahad
    Khan, Md. Arifur Rahman
    [J]. Nanoscience and Nanotechnology - Asia, 2022, 12 (04): : 10 - 28
  • [3] Versatile method of cholinesterase immobilisation via affinity bonds using Concanavalin A applied to the construction of a screen-printed biosensor
    Bucur, B
    Danet, AF
    Marty, JL
    [J]. BIOSENSORS & BIOELECTRONICS, 2004, 20 (02): : 217 - 225
  • [4] Nerve Agents Assay Using Cholinesterase Based Biosensor
    Pohanka, Miroslav
    Dobes, Petr
    Drtinova, Lucie
    Kuca, Kamil
    [J]. ELECTROANALYSIS, 2009, 21 (10) : 1177 - 1182
  • [5] Elements of biosensor construction
    Davis, J
    Vaughan, DH
    Cardosi, MF
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1995, 17 (12) : 1030 - 1035
  • [6] Reactivation of immobilized acetyl cholinesterase in an amperometric biosensor for organophosphorus pesticide
    Gulla, KC
    Gouda, MD
    Thakur, MS
    Karanth, NG
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEIN STRUCTURE AND MOLECULAR ENZYMOLOGY, 2002, 1597 (01): : 133 - 139
  • [7] Amperometric flow-through biosensor for the determination of cholinesterase inhibitors
    Evtugyn, GA
    Ivanov, AN
    Gogol, EV
    Marty, JL
    Budnikov, HC
    [J]. ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) : 13 - 21
  • [8] Potentiometric cholinesterase biosensor with a membrane modified with calix[4]resorcinolarene
    Evtyugin, GA
    Muslinkina, LA
    Budnikov, GK
    Kazakova, EK
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 54 (04) : 367 - 371
  • [9] Electrochemical acetylcholinesterase biosensor for detection of cholinesterase inhibitors: study with eserine
    Lokar, Nina
    Kononenko, Veno
    Drobne, Damjana
    Vrtacnik, Danilo
    [J]. INFORMACIJE MIDEM-JOURNAL OF MICROELECTRONICS ELECTRONIC COMPONENTS AND MATERIALS, 2018, 48 (04): : 235 - 240
  • [10] Cholinesterase-based biosensor using surface photovoltage technique
    Fedosseeva, OV
    Uchida, H
    Katsube, T
    Ishimaru, Y
    Iida, T
    [J]. ELECTROCHEMISTRY, 1999, 67 (07) : 755 - 759