Verification of Acuros Dose Calculation Accuracy in Lung SBRT

被引:0
|
作者
Wang, L. [1 ]
Bush, K. [1 ]
Xing, L. [1 ]
Mok, E. [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA 94305 USA
关键词
D O I
10.1118/1.4735620
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3827 / 3827
页数:1
相关论文
共 50 条
  • [31] Dosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans
    Kroon, Petra S.
    Hol, Sandra
    Essers, Marion
    [J]. RADIATION ONCOLOGY, 2013, 8
  • [32] Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma
    Kan, Monica W. K.
    Leung, Lucullus H. T.
    So, Ronald W. K.
    Yu, Peter K. N.
    [J]. MEDICAL PHYSICS, 2013, 40 (03)
  • [33] Phantom Verification of AAA and Acuros Dose Calculations for Lung Cancer: Do Tumor Size and Regression Matter?
    Shiraishi, Satomi
    de los Santos, Luis E. Fong
    Antolak, John A.
    Olivier, Kenneth R.
    Garces, Yolanda I.
    Park, Sean S.
    Grams, Michael P.
    [J]. PRACTICAL RADIATION ONCOLOGY, 2019, 9 (01) : 29 - 37
  • [34] ACCURACY OF MODERN DOSE CALCULATION ALGORITHMS IN LUNG TISSUE
    Piersma, H.
    Nuver, T.
    Koken, P.
    Damen, E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S71 - S71
  • [35] Dosimetric comparison of peripheral NSCLC SBRT using Acuros XB and AAA calculation algorithms
    Ong, Chloe C. H.
    Ang, Khong Wei
    Soh, Roger C. X.
    Tin, Kah Ming
    Yap, Jerome H. H.
    Lee, James C. L.
    Bragg, Christopher M.
    [J]. MEDICAL DOSIMETRY, 2017, 42 (03) : 216 - 222
  • [36] Accuracy and sensitivity of four-dimensional dose calculation to systematic motion variability in stereotatic body radiotherapy (SBRT) for lung cancer
    Chan, Mark K. H.
    Kwong, Dora L. W.
    Ng, Sherry C. Y.
    Tong, Anthony S. M.
    Tam, Eric K. W.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (06): : 303 - 317
  • [37] Evaluation of Acuros XB Algorithm for Lung SBRT Using Flattening Filter Free
    Sandrini, E.
    da Silva, A.
    Silva, C.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2963 - 2963
  • [38] VERIFICATION DOSIMETRY FOR LUNG SBRT VMAT
    Lilley, J.
    Derbyshire, S.
    Cosgrove, V.
    Thompson, C.
    Thwaites, D. I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S514 - S515
  • [39] Dosimetric Impact of Dose Calculation Algorithms on Lung SBRT Plan for COPD Patients
    Jang, S.
    Lee, S.
    Zhang, X.
    Mak, K.
    Hirsch, A.
    Truong, M.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [40] OPTIMIZING DOSE PRESCRIPTION IN SBRT FOR LUNG LESIONS USING MONTE CARLO CALCULATION
    Widder, J.
    Hollander, M.
    Ubbels, F.
    Bolt, R.
    Langendijk, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S248 - S248