Balloon-expandable versus self-expanding transcatheter aortic valve replacement for bioprosthetic dysfunction: A systematic review and meta-analysis

被引:14
|
作者
Lee, Hsiu-An [1 ,2 ]
Chou, An-Hsun [3 ]
Wu, Victor Chien-Chia [4 ]
Chen, Dong-Yi [4 ]
Lee, Hsin-Fu [4 ]
Lee, Kuang-Tso [4 ]
Chu, Pao-Hsien [4 ]
Cheng, Yu-Ting [1 ]
Chang, Shang-Hung [4 ]
Chen, Shao-Wei [1 ,5 ]
机构
[1] Chang Gung Univ, Div Thorac & Cardiovasc Surg, Chang Gung Mem Hosp, Dept Surg,Linkou Med Ctr, Taoyuan, Taiwan
[2] Chang Bing Show Chwan Mem Hosp, Dept Surg, Div Cardiovasc Surg, Changhua, Taiwan
[3] Chang Gung Univ, Linkou Med Ctr, Chang Gung Mem Hosp, Dept Anesthesiol, Taoyuan, Taiwan
[4] Chang Gung Univ, Chang Gung Mem Hosp, Dept Cardiol, Linkou Med Ctr, Taoyuan, Taiwan
[5] Chang Gung Mem Hosp, Linkou Med Ctr, Ctr Big Data Analyt & Stat, Taoyuan, Taiwan
来源
PLOS ONE | 2020年 / 15卷 / 06期
关键词
PERMANENT PACEMAKER IMPLANTATION; IN-VALVE; TECHNICAL CONSIDERATIONS; SURGICAL BIOPROSTHESES; MEDTRONIC COREVALVE; PROSTHESIS; PREDICTORS; OUTCOMES; PERFORMANCE; MISMATCH;
D O I
10.1371/journal.pone.0233894
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Transcatheter aortic valve-in-valve (VIV) procedure is a safe alternative to conventional reoperation for bioprosthetic dysfunction. Balloon-expandable valve (BEV) and self-expanding valve (SEV) are the 2 major types of devices used. Evidence regarding the comparison of the 2 valves remains scarce. Methods A systematic review and meta-analysis was conducted to compare the outcomes of BEV and SEV in transcatheter VIV for aortic bioprostheses dysfunction. A computerized search of Medline, PubMed, Embase, and Cochrane databases was performed. Englishlanguage journal articles reporting SEV or BEV outcomes of at least 10 patients were included. Results In total, 27 studies were included, with 2,269 and 1,671 patients in the BEV and SEV groups, respectively. Rates of 30-day mortality and stroke did not differ significantly between the 2 groups. However, BEV was associated with significantly lower rates of postprocedural permanent pacemaker implantation (3.8% vs. 12%; P < 0.001). Regarding echocardiographic parameters, SEV was associated with larger postprocedural effective orifice area at 30 days (1.53 cm(2) vs. 1.23 cm(2); P < 0.001) and 1 year (1.55 cm(2) vs. 1.22 cm(2); P < 0.001). Conclusions For patients who underwent transcatheter aortic VIV, SEV was associated with larger post-procedural effective orifice area but higher rates of permanent pacemaker implantation. These findings provide valuable information for optimizing device selection for transcatheter aortic VIV.
引用
收藏
页数:14
相关论文
共 50 条
  • [22] Comparative meta-analysis of balloon-expandable and self-expandable valves for transcatheter aortic valve replacement
    Agarwal, Shikhar
    Parashar, Akhil
    Kumbhani, Dharam J.
    Svensson, Lars G.
    Krishnaswamy, Amar
    Tuzcu, E. Murat
    Kapadia, Samir R.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 197 : 87 - 97
  • [23] Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve
    Kiramijyan, Sarkis
    Magalhaes, Marco A.
    Koifman, Edward
    Didier, Romain
    Escarcega, Ricardo O.
    Baker, Nevin C.
    Negi, Smita I.
    Minha, Sa'ar
    Torguson, Rebecca
    Gai Jiaxiang
    Asch, Federico M.
    Wang, Zuyue
    Okubagzi, Petros
    Gaglia, Michael A., Jr.
    Ben-Dor, Itsik
    Satler, Lowell F.
    Pichard, Augusto D.
    Waksman, Ron
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (09): : 1502 - 1510
  • [24] Comparison of Transcatheter Aortic Valve Replacement between Self-Expanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus
    Lee, Yong-Joon
    Lee, Seung-Jun
    Hong, Sung-Jin
    Shim, Chi-Young
    Ahn, Chul-Min
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Hong, Geu-Ru
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    KOREAN CIRCULATION JOURNAL, 2021, 51 (03) : 222 - 231
  • [25] Long-Term Clinical Outcome and Performance of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Replacement
    Scotti, Andrea
    Fovino, Luca Nai
    Massussi, Mauro
    Cardaioli, Francesco
    Rodino, Giulio
    Montonati, Carolina
    Continisio, Saverio
    Boiago, Mauro
    Diliberti, Alessandro
    Benedetti, Alice
    Lorenzoni, Giulia
    Gregori, Dario
    Matsuda, Yuji
    Cacciavillani, Luisa
    Pavei, Andrea
    Masiero, Giulia
    Napodano, Massimo
    Fraccaro, Chiara
    Fabris, Tommaso
    Iliceto, Sabino
    Tarantini, Giuseppe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B23 - B23
  • [26] Contemporary Transcatheter Aortic Valve Replacement Experience With Third-generation Balloon-expandable Versus Self-expanding Devices
    Rogers, Toby
    Steinvil, Arie
    Koifman, Edward
    Buchanan, Kyle
    Alraies, Chadi
    Okubagzi, Petros
    Torguson, Rebecca
    Ben-Dor, Itsik
    Pichard, Augusto
    Satler, Lowell
    Waksman, Ron
    JACC-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (03) : S66 - S66
  • [27] THROMBOCYTOPENIA AFTER TRANSCATHETER AORTIC VALVE REPLACEMENT: A COMPARISON BETWEEN BALLOON-EXPANDABLE AND SELF-EXPANDING PROSTHESIS
    Pujol-Lopez, Margarida
    Hernandez-Enriquez, Marco
    Andrea, Rut
    Regueiro, Ander
    Antoni Gomez-Hospital, Joan
    Romaguera, Rafael
    Cequier, Angel
    Sabate, Manel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1040 - 1040
  • [28] 1-Year Outcomes of Transcatheter Aortic Valve Replacement Using a Self-Expanding vs Balloon-Expandable Transcatheter Aortic Valve
    Kim, Won-Keun
    Pellegrini, Costanza
    Eckel, Clemens
    Renker, Matthias
    Grothusen, Christina
    Choi, Yeong-Hoon
    Charitos, Efstratios I.
    Duesmann, Charlotte
    Blumenstein, Johannes
    Rheude, Tobias
    Sossalla, Samuel
    Joner, Michael
    Moellmann, Helge
    JACC-CARDIOVASCULAR INTERVENTIONS, 2025, 18 (01) : 32 - 40
  • [29] Self-expanding and balloon-expandable transfemoral transcatheter aortic valve replacement: in-hospital outcomes in Germany
    Oettinger, V.
    Zehender, M.
    Bode, C.
    Kaier, K.
    Muehlen, C. Von Zur
    Stachon, P.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2174 - 2174
  • [30] Procedural Aspects of Transcatheter Aortic Valve Replacement: Comparison Between Balloon-Expandable and Self-Expanding Devices
    Andreka, Judit
    Stark, Cosima
    Deharo, Pierre
    Adamaszek, Martin
    Regueiro, Ander
    Prunea, Dan
    Maaroufi, Anass
    Ruzsa, Zoltan
    Cuisset, Thomas
    Schmidt, Albrecht
    Brugaletta, Salvatore
    Toth, Gabor
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B385 - B385