Magnetic resonance imaging of the zone of calcified cartilage in the knee joint using 3-dimensional ultrashort echo time cones sequences

被引:8
|
作者
Liu, Jin [1 ]
Wei, Yang [2 ]
Ma, Ya-Jun [3 ]
Zhu, Yan-Chun [3 ]
Zhou, Quan [1 ]
Zhao, Ying-Hua [1 ,3 ]
机构
[1] Southern Med Univ, Dept Radiol, Affiliated Hosp 3, Acad Orthoped, Guangzhou 510630, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Key Lab Med Image Proc, Sch Biomed Engn, Guangzhou 510515, Guangdong, Peoples R China
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
关键词
Ultrashort echo time; T2*relaxation time; Zone of calcified cartilage; Articular cartilage; ARTICULAR-CARTILAGE; SUBCHONDRAL BONE; RESOLUTION;
D O I
10.1097/CM9.0000000000000103
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The zone of calcified cartilage (ZCC) plays an important role in the pathogenesis of osteoarthritis (OA) but has never been imaged in vivo with magnetic resonance (MR) imaging techniques. We investigated the feasibility of direct imaging of the ZCC in both cadaveric whole knee specimens and in vivo healthy knees using a 3-dimensional ultrashort echo time cones (3D UTE-Cones) sequence on a clinical 3T scanner. Methods: In all, 12 cadaveric knee joints and 10 in vivo healthy were collected. At a 3T MR scanner with an 8-channel knee coil, a fat-saturated 3D dual-echo UTE-Cones sequence was used to image the ZCC, following with a short rectangular pulse excitation and 3D spiral sampling with conical view ordering. The regions of interests (ROIs) were delineated by a blinded observer. Single-component T2* and T2 values were calculated from fat-saturated 3D dual-echo UTE-Cones and a Carr-Purcell-Meiboom-Gill (T2 C:PMG) data using a semi-automated MATLAB code. Results: The single-exponential fitting curve of ZCC was accurately obtained with R2 of 0.989. For keen joint samples, the ZCC has a short T2* ranging from 0.62 to 2.55 ms, with the mean +/- standard deviation (SD) of 1.49 +/- 0.66 ms, and with 95% confidence intervals (CI) of 1.20-1.78 ms. For volunteers, the short T2* ranges from 0.93 to 3.52 ms, with the mean +SD of 2.09 +/- 0.56 ms, and the 95% CI is 1.43 to 2.74 ms in ZCC. Conclusions: The high-resolution 3D UTE-Cones sequence might be used to directly image ZCC in the human knee joint on a clinical 3T scanner with a scan time of more than 10 min. Using this non-invasive technique, the T2* relaxation time of the ZCC can he further detected.
引用
收藏
页码:562 / 568
页数:7
相关论文
共 50 条
  • [21] Dual inversion recovery ultrashort echo time (DIR-UTE) imaging and quantification of the zone of calcified cartilage (ZCC)
    Du, J.
    Carl, M.
    Bae, W. C.
    Statum, S.
    Chang, E. Y.
    Bydder, G. M.
    Chung, C. B.
    OSTEOARTHRITIS AND CARTILAGE, 2013, 21 (01) : 77 - 85
  • [22] Magnetic resonance imaging of the knee with ultrashort TE pulse sequences
    Gatehouse, PD
    Thomas, RW
    Robson, MD
    Hamilton, G
    Herlihy, AH
    Bydder, GM
    MAGNETIC RESONANCE IMAGING, 2004, 22 (08) : 1061 - 1067
  • [23] Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Fan, Shu-Juan
    Wong, Jonathan
    Xue, Yanping
    Cai, Zhenyu
    Chang, Eric Y.
    Corey-Bloom, Jody
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [24] Quantitative differentiation of tendon and ligament using magnetic resonance imaging ultrashort echo time T2*mapping of normal knee joint
    Okuda, Miho
    Kobayashi, Satoshi
    Toyooka, Kazu
    Yoshimizu, Rikuto
    Nakase, Junsuke
    Hayashi, Hiroyuki
    Ueda, Yu
    Gabata, Toshifumi
    ACTA RADIOLOGICA, 2022, 63 (11) : 1489 - 1496
  • [25] An Update in Qualitative Imaging of Bone Using Ultrashort Echo Time Magnetic Resonance
    Jerban, Saeed
    Chang, Douglas G.
    Ma, Yajun
    Jang, Hyungseok
    Chang, Eric Y.
    Du, Jiang
    FRONTIERS IN ENDOCRINOLOGY, 2020, 11
  • [26] Measurement of cartilage thickness in the human knee-joint by magnetic resonance imaging using a three-dimensional gradient-echo sequence
    Kladny, B
    Martus, P
    Schiwy-Bochat, KH
    Weseloh, G
    Swoboda, B
    INTERNATIONAL ORTHOPAEDICS, 1999, 23 (05) : 264 - 267
  • [27] Measurement of cartilage thickness in the human knee-joint by magnetic resonance imaging using a three-dimensional gradient-echo sequence
    B. Kladny
    P. Martus
    K. -H. Schiwy-Bochat
    G. Weseloh
    B. Swoboda
    International Orthopaedics, 1999, 23 : 264 - 267
  • [28] Ultrashort echo time magnetic resonance imaging of the osteochondral junction
    Lombardi, Alecio F.
    Guma, Monica
    Chung, Christine B.
    Chang, Eric Y.
    Du, Jiang
    Ma, Ya-Jun
    NMR IN BIOMEDICINE, 2023, 36 (02)
  • [29] Depiction of Achilles Tendon Microstructure In Vivo Using High-Resolution 3-Dimensional Ultrashort Echo-Time Magnetic Resonance Imaging at 7 T
    Han, Misung
    Larson, Peder E. Z.
    Liu, Jing
    Krug, Roland
    INVESTIGATIVE RADIOLOGY, 2014, 49 (05) : 339 - 345
  • [30] Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging
    Ren, Cui
    Zhu, Qiao
    Li, Qing
    Sommer, Stefan
    Zhang, Xianchang
    Yuan, Huishu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (06) : 4141 - 4154