Photoacoustic spectroscopic imaging of intra-tumor heterogeneity and molecular identification

被引:12
|
作者
Stantz, Keith M. [1 ,2 ]
Liu, Bo [1 ]
Cao, Minsong [1 ]
Reinecke, Dan [3 ]
Miller, Kathy [2 ]
Kruger, Robert [3 ]
机构
[1] Purdue Univ, W Lafayette, IN 47907 USA
[2] Indiana Univ, Indianapolis, IN 46204 USA
[3] Optosonics Inc, Indianapolis, IN USA
关键词
photoacoustic spectroscopy; oxyhemoglobin; idocyanine green; breast cancer; ovarian cancer;
D O I
10.1117/12.645106
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose. To evaluate photoacoustic spectroscopy as a potential imaging modality capable of measuring intra-tumor heterogeneity and spectral features associated with hemoglobin and the molecular probe indocyanine green (ICG). Material and Methods. Immune deficient mice were injected with wildtype and VEGF enhanced MCF-7 breast cancer cells or SKOV3x ovarian cancer cells, which were allowed to grow to a size of 6-12 mm in diameter. Two mice were imaged alive and after euthanasia for (oxy/deoxy)-hemoglobin content. A 0.4 mL volume of 1 mu g/mL concentration of ICG was injected into the tail veins of two mice prior to imaging using the photoacoustic computed tomography (PCT) spectrometer (Optosonics, Inc., Indianapolis, IN 46202) scanner. Mouse images were acquired for wavelengths spanning 700-920 nm, after which the major organs were excised, and similarly imaged. A histological study was performed by sectioning the organ and optically imaging the fluorescence distribution. Results. Calibration of PCT-spectroscopy with different samples of oxygenated blood reproduced a hemoglobin dissociation curve consistent with empirical formula with an average error of 5.6%. In vivo PCT determination of SaO(2) levels within the tumor vascular was measurably tracked, and spatially correlated to the periphery of the tumor. Statistical and systematic errors associated with hypoxia were estimated to be 10 and 13%, respectively. Measured ICG concentrations determined by contrast-differential PCT images in excised organs (tumor, liver) were approximately 0.8 mu g/mL, consistent with fluorescent histological results. Also, the difference in the ratio of ICG concentration in the gall bladder-to-vasculature between the mice was consistent with excretion times between the two mice. Conclusion. PCT spectroscopic imaging has shown to be a noninvasive modality capable of imaging intra-tumor heterogeneity of (oxy/deoxy)-hemoglobin and ICG in vivo, with an estimated error in SaO(2) at 17% and in ICG at 0.8 mu g/mL in excised tissue. Ongoing development of spectroscopic analysis techniques, probe development, and calibration techniques are being developed to improve sensitivity to both exogenous molecular probes and (oxy/deoxy)-hemoglobin fraction.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Intra-tumor heterogeneity from a cancer stem cell perspective
    Pramudita R. Prasetyanti
    Jan Paul Medema
    Molecular Cancer, 16
  • [32] Intra-tumor heterogeneity for endometrial cancer and its clinical significance
    Yin Fu-Fen
    Zhao Li-Jun
    Ji Xiao-Yu
    Duan Ning
    Wang Yan-Kui
    Zhou Jing-Yi
    Wei Li-Hui
    He Xiang-Jun
    Wang Jian-Liu
    Li Xiao-Ping
    中华医学杂志(英文版), 2019, 132 (13) : 1550 - 1562
  • [33] Intra-tumor heterogeneity for endometrial cancer and its clinical significance
    Yin, Fu-Fen
    Zhao, Li-Jun
    Ji, Xiao-Yu
    Duan, Ning
    Wang, Yan-Kui
    Zhou, Jing-Yi
    Wei, Li-Hui
    He, Xiang-Jun
    Wang, Jian-Liu
    Li, Xiao-Ping
    CHINESE MEDICAL JOURNAL, 2019, 132 (13) : 1550 - 1562
  • [34] Intra-Tumor Heterogeneity (ITH) in Acute Myeloid Leukemia (AML)
    Cerrano, Marco
    Passet, Marie
    Vasseur, Loic
    Rabian, Florence
    Rhame, Rhamy
    Lengline, Etienne
    Raffoux, Emmanuel
    Dhedin, Nathalie
    Cabannes-Hamy, Aurelie
    Rahal, Ilhem
    Sebert, Marie
    Cucuinni, Wendy
    Maarek, Odile
    Raimbault, Anna
    Mathis, Stephanie
    Celli-Lebras, Karine
    Ades, Lionel
    Fenaux, Pierre
    Boissel, Nicolas
    Soulier, Jean
    Dombret, Herve
    Sujobert, Pierre
    Clappier, Emmanuelle
    Itzykson, Raphael
    CLINICAL LYMPHOMA MYELOMA & LEUKEMIA, 2019, 19 : S237 - S237
  • [35] Understanding intra-tumor heterogeneity and tumor evolution to facilitate hepatocellular carcinoma therapy
    Xue, Ruidong
    Li, Ruoyan
    Zhang, Ning
    Bai, Fan
    TRANSLATIONAL CANCER RESEARCH, 2016, 5 : S604 - S605
  • [36] Intra-Tumor Genetic Heterogeneity in Wilms Tumor: Clonal Evolution and Clinical Implications
    Cresswell, George D.
    Apps, John R.
    Chagtai, Tasnim
    Mifsud, Borbala
    Bentley, Christopher C.
    Maschietto, Mariana
    Popov, Sergey D.
    Weeks, Mark E.
    Olsen, Oystein E.
    Sebire, Neil J.
    Pritchard-Jones, Kathy
    Luscombe, Nicholas M.
    Williams, Richard D.
    Mifsud, William
    EBIOMEDICINE, 2016, 9 : 120 - 129
  • [37] Imaging-based representation and stratification of intra-tumor heterogeneity via tree-edit distance
    Lara Cavinato
    Matteo Pegoraro
    Alessandra Ragni
    Martina Sollini
    Paola Anna Erba
    Francesca Ieva
    Scientific Reports, 12 (1)
  • [38] Assessing Intra-Tumor Hemodynamics and Oxygen Concentration Using Photoacoustic Computed Tomography
    Stantz, K.
    Cao, N.
    Shaffer, M.
    Miller, K. D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [39] Imaging-based representation and stratification of intra-tumor heterogeneity via tree-edit distance
    Cavinato, Lara
    Pegoraro, Matteo
    Ragni, Alessandra
    Ieva, Francesca
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [40] Novel voxel-wise textural feature analysis for intra-tumor heterogeneity characterization in PET imaging
    Le Pogam, Adrien
    Tixier, Florent
    Hatt, Mathieu
    Cheze-Le Rest, Catherine
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53