Conventionally-fractionated image-guided intensity modulated radiotherapy (IG-IMRT): a safe and effective treatment for cancer spinal metastasis

被引:32
|
作者
Gong, Youling [2 ,3 ]
Wang, Jin [3 ]
Bai, Sen [4 ]
Jiang, Xiaoqin [4 ]
Xu, Feng [1 ]
机构
[1] Sichuan Univ, W China Hosp, Tumor Ctr, Dept Abdominal Oncol, Chengdu 610041, Sichuan Prov, Peoples R China
[2] Sichuan Univ, W China Hosp, State Key Lab Biotherapy, Chengdu 610041, Sichuan Prov, Peoples R China
[3] Sichuan Univ, W China Hosp, Tumor Ctr, Dept Thorac Oncol, Chengdu 610041, Sichuan Prov, Peoples R China
[4] Sichuan Univ, W China Hosp, Tumor Ctr, Radiat & Phys Ctr, Chengdu 610041, Sichuan Prov, Peoples R China
关键词
D O I
10.1186/1748-717X-3-11
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Treatments for cancer spinal metastasis were always palliative. This study was conducted to investigate the safety and effectiveness of IG-IMRT for these patients. Methods: 10 metastatic lesions were treated with conventionally-fractionated IG-IMRT. Daily kilovoltage cone-beam computed tomography (kV-CBCT) scan was applied to ensure accurate positioning. Plans were evaluated by the dose-volume histogram (DVH) analysis. Results: Before set-up correction, the positioning errors in the left-right (LR), superior-inferior (SI) and anterior-posterior (AP) axes were 0.3 +/- 3.2, 0.4 +/- 4.5 and -0.2 +/- 3.9 mm, respectively. After repositioning, those errors were 0.1 +/- 0.7, 0 +/- 0.8 and 0 +/- 0.7 mm, respectively. The systematic/random uncertainties ranged 1.4-2.3/3.0-4.1 before and 0.1-0.2/0.7-0.8 mm after online set-up correction. In the original IMRT plans, the average dose of the planning target volume (PTV) was 61.9 Gy, with the spinal cord dose less than 49 Gy. Compared to the simulated PTVs based on the pre-correction CBCT, the average volume reduction of PTVs was 42.3% after online correction. Also, organ at risk (OAR) all benefited from CBCT-basedset- up correction and had significant dose reduction with IGRT technique. Clinically, most patients had prompt pain relief within one month of treatment. There was no radiation-induced toxicity detected clinically during a median follow-up of 15.6 months. Conclusion: IG-IMRT provides a new approach to treat cancer spinal metastasis. The precise positioning ensures the implementation of optimal IMRT plan, satisfying both the dose escalation of tumor targets and the radiation tolerance of spinal cord. It might benefit the cancer patient with spinal metastasis.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Image-guided intensity-modulated radiation therapy (IG-IMRT) with helical tomotherapy for prostate cancer - Importance of patient registration for alignment
    Desai, S. S.
    McGary, J. E.
    Teh, B. S.
    Smiedala, M.
    Grant, W.
    Paulino, A. C.
    Butler, E. B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S379 - S379
  • [12] Image-guided, intensity-modulated radiation therapy (IG-IMRT) for skull base chordoma and chondrosarcoma: preliminary outcomes
    Sahgal, Arjun
    Chan, Michael W.
    Atenafu, Eshetu G.
    Masson-Cote, Laurence
    Bahl, Gaurav
    Yu, Eugene
    Millar, Barbara-Ann
    Chung, Caroline
    Catton, Charles
    O'Sullivan, Brian
    Irish, Jonathan C.
    Gilbert, Ralph
    Zadeh, Gelareh
    Cusimano, Michael
    Gentili, Fred
    Laperriere, Normand J.
    NEURO-ONCOLOGY, 2015, 17 (06) : 889 - 894
  • [13] Preliminary clinical outcomes of daily ultrasound image-guided intensity modulated radiation therapy (IG-IMRT) in the treatment of primary cancers of the gallbladder.
    Fuller, CD
    Wong, A
    Cavanaugh, SX
    Thomas, CR
    Salter, B
    Fuss, M
    JOURNAL OF CLINICAL ONCOLOGY, 2005, 23 (16) : 354S - 354S
  • [14] Image-guided intensity modulated radiation therapy (IG-IMRT) for extrahepatic cholangiocarcinoma: Results from a mature case control comparison with conventional radiotherapy (CRT)
    Fuller, C. D.
    Starling, G. D.
    Wong, A.
    Wang, S. J.
    Thomas, C. R.
    Fuss, M.
    EJC SUPPLEMENTS, 2007, 5 (04): : 273 - 274
  • [15] Image-guided, fractionated intensity modulated cranial radiotherapy for the treatment of patients with brain metastases
    Rogers, S.
    Schwyzer, L.
    Egli, P.
    Fujak, E.
    Rabe, E.
    Schuerkens, J.
    Busch, B.
    Ziese, S.
    Khan, S.
    Roelcke, U.
    Lutters, G.
    Bodis, S.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 746 - 747
  • [16] Is Daily Image-guided Radiotherapy (IGRT) Really Necessary in the Treatment of Head and Neck Cancer with Intensity-modulated Radiotherapy (IMRT)?
    Marsano, J. G.
    Won, S.
    Li, B.
    Sreeraman, R.
    Michaud, A.
    Perks, J.
    Purdy, J. A.
    Chen, A. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S638 - S639
  • [17] The technical feasibility of an image-guided intensity-modulated radiotherapy (IG-IMRT) to perform a hypofractionated schedule in terms of toxicity and local control for patients with locally advanced or recurrent pancreatic cancer
    Son, Seok Hyun
    Song, Jin Ho
    Choi, Byung Ock
    Kang, Young-nam
    Lee, Myung Ah
    Kang, Ki Mun
    Jang, Hong Seok
    RADIATION ONCOLOGY, 2012, 7
  • [18] The technical feasibility of an image-guided intensity-modulated radiotherapy (IG-IMRT) to perform a hypofractionated schedule in terms of toxicity and local control for patients with locally advanced or recurrent pancreatic cancer
    Seok Hyun Son
    Jin Ho Song
    Byung Ock Choi
    Young nam Kang
    Myung Ah Lee
    Ki Mun Kang
    Hong Seok Jang
    Radiation Oncology, 7
  • [19] A review of image-guided intensity-modulated radiotherapy for spinal tumors
    Yamada, Yoshiya
    Lovelock, D. Michael
    Bilsky, Mark H.
    NEUROSURGERY, 2007, 61 (02) : 226 - 235
  • [20] Image-guided and intensity-modulated radiosurgery for patients with spinal metastasis
    Ryu, S
    Yin, FF
    Rock, J
    Zhu, JE
    Chu, A
    Kagan, E
    Rogers, L
    Ajlouni, M
    Rosenblum, M
    Kim, JH
    CANCER, 2003, 97 (08) : 2013 - 2018