摘要
The objective of this study was to evaluate the CombiScope FTIR equipment based on Fourier Transform Infrared methodology (FTIR), to assess the content of milk urea nitrogen (MUN) in Brazil. Repeatability and reproducibility of CombiScope (TM) FTIR (Delta Instruments), and comparison with an enzymatic automated method (Chemspec (R) 150; Bentley Instruments) were tested to measure raw milk urea nitrogen (MUN). Additionally, MUN levels stability after storage of raw milk samples at 4 degrees C, and 20 degrees C for up to 15 days, and capability and precision to detect extraneous urea added as an adulterant to the milk were evaluated by FTIR equipment. There was a high correlation coefficient for the analysis of MUN by FTIR equipment, when compared with the automated enzymatic method, with no significant difference between both. MUN concentration in raw milk remained stable at temperatures of 4 degrees C for up to 15 days of storage, but after 3 days of storage at 20 degrees C there was an increase in the MUN levels. The CombiScope FTIR equipment proved to be a reliable method for analysis of MUN content in raw milk. However, results for MUN were not linear with the amount of extraneous urea added to raw milk, having a significant difference for samples when 40mg/dL of urea was added to milk.
引用
收藏
页码:1360 / 1366
页数:7
相关论文
共 50 条
  • [31] PHOTO-ACOUSTIC FOURIER-TRANSFORM INFRARED (FTIR) SPECTROSCOPY
    KRISHNAN, K
    HILL, SL
    WITEK, H
    KNECHT, J
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 96 - 98
  • [32] Edible Oil Discrimination by Fourier Transform Infrared (FTIR) Spectroscopy and Chemometrics
    Bunaciu, Andrei A.
    Vu, Dang Hoang
    Aboul-Enein, Hassan Y.
    ANALYTICAL LETTERS, 2024, 57 (03) : 445 - 455
  • [33] Role of Fourier transform infrared spectroscopy (FTIR) in the diagnosis of parathyroid pathology
    Das, Kaustuv
    Stone, Nicholas
    Kendall, Catherine
    Fowler, Clare
    Christie-Brown, J.
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2007, 4 (02) : 124 - 129
  • [34] FOURIER-TRANSFORM INFRARED (FTIR) SPECTROSCOPY FOR IDENTIFYING LACTOBACILLUS SPECIES
    CURK, MC
    PELADAN, F
    HUBERT, JC
    FEMS MICROBIOLOGY LETTERS, 1994, 123 (03) : 241 - 248
  • [35] Identification of lactic acid bacteria by Fourier Transform Infrared Spectroscopy (FTIR)
    Amiel, C
    Travert, J
    Curk-Daubie, MC
    Pichon, P
    Lefier, D
    Mariey, L
    SPECTROSCOPY OF BIOLOGICAL MOLECULES: NEW DIRECTIONS, 1999, : 563 - 564
  • [36] QUANTITATIVE DIFFUSE REFLECTANCE FOURIER-TRANSFORM INFRARED (FTIR) SPECTROSCOPY
    CARROLL, JE
    DOYLE, WM
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1981, 289 : 111 - 113
  • [37] Authentication of olive oil adulterated with vegetable oils using Fourier transform infrared spectroscopy
    Tay, A
    Singh, RK
    Krishnan, SS
    Gore, JP
    LEBENSMITTEL-WISSENSCHAFT UND-TECHNOLOGIE-FOOD SCIENCE AND TECHNOLOGY, 2002, 35 (01): : 99 - 103
  • [38] Detection of Milk Quality Utilizing Fourier Transform Infrared Spectroscopy
    Momin, Abdul
    Rohith, Chennoju Sai
    Pranav, Gattamaneni
    Sathwik, Puchalapalli
    Gangashctty, Suryakanth, V
    2024 4TH INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND SOCIAL NETWORKING, ICPCSN 2024, 2024, : 769 - 772
  • [39] Discriminant Analysis and Cluster Analysis of Biodiesel Fuel Blends Based on Fourier Transform Infrared Spectroscopy (FTIR)
    dos Santos, Victor Hugo J. M.
    Bruzza, Eduardo Do Canto
    de Lima, Jeane E.
    Lourega, Rogerio V.
    Rodrigues, Luiz F.
    ENERGY & FUELS, 2016, 30 (06) : 4905 - 4915
  • [40] Characteristics Analysis of the Thyroid Gland Surface of Normal Human with Fourier Transform Infrared (FTIR) Spectra
    Wu Min
    Zhang Wei-tao
    Tian Pei-rong
    Ling Xiao-feng
    Xu Zhi
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2016, 36 (10) : 3092 - 3096