Impact of vessel curvature on neointimal healing after stent implantation as assessed by optical coherence tomography

被引:3
|
作者
Fu, Yandong [1 ]
Zhang, Shaotao [1 ]
Du, Hongwei [1 ]
Li, Lulu [1 ]
Wang, Chao [1 ]
Zheng, Gonghui [1 ]
Wang, Yan [1 ]
Dong, Hui [1 ]
Jia, Haibo [1 ]
Yu, Bo [1 ]
机构
[1] Harbin Med Univ, Dept Cardiol, Affiliated Hosp 2, Harbin, Heilongjiang, Peoples R China
关键词
neointimal healing; optical coherence tomography; vessel curvature; ENDOTHELIAL SHEAR-STRESS; CORONARY-ARTERY-DISEASE; ELUTING STENT; FOLLOW-UP; RESTENOSIS; COVERAGE; WALL; PLAQUE; PROGRESSION; CORRELATE;
D O I
10.1097/MD.0000000000010518
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose:Previous studies have indicated that stent implantation could alter the vessel geometry, which may impact the neointimal healing process. Curvature is an important parameter for evaluating vessel geometry. The purpose of our study was to investigate the relationship between vessel curvature and neointimal healing after stent implantation. Methods:Fifty-nine patients with acute coronary syndrome (ACS) who underwent stent implantation were enrolled in the study. According to the post-percutaneous coronary intervention vessel curvature measured by quantitative coronary angiography, patients were divided into high (n=30) and low (n=29) curvature groups. Neointimal thickness and area together with the neointimal type were assessed by optical coherence tomography at a 6-month follow-up. Results:Baseline clinical characteristics were comparable between the 2 groups. The vessel curvature at pre- and 6-month follow-up was significantly higher in the high curvature group than the low curvature group. At 6-month follow-up, neointimal thickness (0.22 [0.08-0.32] mm vs. 0.10 [0.07-0.16] mm, P=.043) and neointimal area (1.86 [0.66-2.66] vs. 0.82 [0.60-1.41] mm(2), P=.030) were significantly higher in the high curvature group than the low curvature group. In the high curvature group, the incidence of the heterogeneous neointimal type was higher than that in the low curvature group (50.00% vs. 17.20%, respectively, P=.004), whereas the frequency of the homogeneous neointimal type was lower (43.30% vs. 82.80%, respectively, P=.004) in the high curvature group than the low curvature group. Conclusion:Higher vessel curvature after stent implantation may potentially have an impact on the neointimal healing with a higher incidence of heterogeneous neointimal.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Impact of Diabetes Mellitus on Vascular Healing Process After Everolimus-Eluting Stent Implantation: An Optical Coherence Tomography Study
    Hioki, Hirofumi
    Brugaletta, Salvatore
    Gomez-Lara, Josep
    Romaguera, Rafael
    Fuentes, Lara
    Cequier, Angel
    Herrera, Raul
    Jimenez-Quevedo, Pilar
    Otsuki, Shuji
    Masotti, Monica
    Sabate, Manel
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2022, 35 : 44 - 50
  • [42] DIFFERENCE BETWEEN CORONARY ANGIOSCOPY AND OPTICAL COHERENCE TOMOGRAPHY IN THE ASSESSMENT OF NEOINTIMAL FINDINGS AT FOLLOW UP AFTER STENT IMPLANTATION
    Taichi, Nakamura
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 1425 - 1425
  • [43] CORRELATION BETWEEN DEGREE OF NEOINTIMAL HYPERPLASIA AND INCIDENCE AND CHARACTERISTICS OF NEOATHEROSCLEROSIS AFTER STENT IMPLANTATION: AN OPTICAL COHERENCE TOMOGRAPHY STUDY
    Vergallo, Rocco
    Yonetsu, Taishi
    Lee, Stephen
    Uemura, Shiro
    Kato, Koji
    Jia, Haibo
    Abtahian, Farhad
    Tian, Jinwei
    Hu, Sining
    Aguirre, Aaron
    McNulty, Iris
    Lee, Hang
    Zhang, Shaosong
    Yu, Bo
    Porto, Italo
    Biasucci, Luigi
    Crea, Filippo
    Jang, Ik-Kyung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E1800 - E1800
  • [44] FEATURES OF NEOINTIMAL MORPHOLOGY OBSERVED BY OPTICAL COHERENCE TOMOGRAPHY BEYOND 3 YEARS AFTER EVEROLIMUS ELUTING STENT IMPLANTATION
    Yonetsu, Taishi
    Hamaya, Rikuta
    Ohya, Hiroaki
    Sumino, Yohei
    Fukuda, Tadashi
    Hada, Masahiro
    Usui, Eisuke
    Hoshino, Masahiro
    Kanaji, Yoshihisa
    Kakuta, Tsunekazu
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1242 - 1242
  • [45] CLOPIDOGREL RESISTANCE AND INTRA-STENT THROMBI ASSESSED BY OPTICAL COHERENCE TOMOGRAPHY AFTER DRUG-ELUTING STENT IMPLANTATION
    Fukuhara, Kenzo
    Okura, Hiroyuki
    Koyama, Terumasa
    Yamada, Ryotaro
    Kume, Teruyoshi
    Hayashida, Akihiro
    Neishi, Yoji
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1607 - A1607
  • [46] Coronary plaque response after drug eluting stent implantation assessed by serial optical coherence tomography analysis
    TIAN FengCHEN YundaiCHEN LianSUN ZhijunLIU ChangfuGUO JunJIN Qinhua WANG Jinda and GAI Luyue Department of CardiologyChinese Peoples Liberation Army General HospitalBeijing China
    中华医学杂志(英文版), 2011, (22) : 3752 - 3756
  • [47] "Baumkuchen" Structure Assessed by Optical Coherence Tomography After 15 Years of Bare-Metal Stent Implantation
    Yukimitsu, Nozomu
    Hioki, Hirofumi
    Kyono, Hiroyuki
    Nagura, Fukuko
    Kozuma, Ken
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (23) : 2431 - 2432
  • [48] Coronary plaque response after drug eluting stent implantation assessed by serial optical coherence tomography analysis
    Tian Feng
    Chen Yun-dai
    Chen Lian
    Sun Zhi-jun
    Liu Chang-fu
    Guo Jun
    Jin Qin-hua
    Wang Jin-da
    Gai Lu-yue
    CHINESE MEDICAL JOURNAL, 2011, 124 (22) : 3752 - 3756
  • [49] Automated detection of vessel lumen and stent struts in intravascular optical coherence tomography to evaluate stent apposition and neointimal coverage
    Nam, Hyeong Soo
    Kim, Chang-Soo
    Lee, Jae Joong
    Song, Joon Woo
    Kim, Jin Won
    Yoo, Hongki
    MEDICAL PHYSICS, 2016, 43 (04) : 1662 - 1675
  • [50] Evaluation of aneurysm after coronary stent implantation by optical coherence tomography
    Karabay, Can Yucel
    Kocabay, Gonenc
    Tasar, Onur
    Kalayci, Arzu
    Guler, Ahmet
    Kirma, Cevat
    KARDIOLOGIA POLSKA, 2013, 71 (06) : 659 - 659