UVC Germicidal Units: Determination of Dose Received and Parameters to be Considered for N95 Respirator Decontamination and Reuse

被引:12
|
作者
Kohli, Indermeet [1 ,2 ]
Lyons, Alexis B. [1 ]
Golding, Bob [3 ]
Narla, Shanthi [1 ]
Torres, Angeli E. [1 ]
Parks-Miller, Angela [1 ]
Ozog, David [1 ]
Lim, Henry W. [1 ]
Hamzavi, Iltefat H. [1 ]
机构
[1] Henry Ford Hlth Syst, Dept Dermatol, Photomed & Photobiol Unit, Detroit, MI 48202 USA
[2] Wayne State Univ, Dept Phys & Astron, Detroit, MI 48202 USA
[3] Daavlin, Bryan, OH USA
关键词
D O I
10.1111/php.13322
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The COVID-19 pandemic has resulted in an international shortage of personal protective equipment including N95 filtering facepiece respirators (FFRs), resulting in many institutions using ultraviolet germicidal irradiation (UVGI) technology for N95 FFR decontamination. To ensure proper decontamination, it is crucial to determine the dose received by various parts of the FFR in this process. Recently, our group customized a UVGI unit for N95 decontamination. With experimental and theoretical approach, this manuscript discusses the minimum dose received by various parts of the N95 respirator after one complete decontamination cycle with this UVGI unit. The results demonstrate that all parts of the N95 FFR received at least 1 J cm(-2)after one complete decontamination cycle with this unit. As there are a variety of UVGI devices and different types of FFRs, this study provides a model by which UVC dose received by different areas of the FFRs can be accurately assessed to ensure proper decontamination for the safety of healthcare providers.
引用
收藏
页码:1083 / 1087
页数:5
相关论文
共 50 条
  • [21] Effects of Ultraviolet Germicidal Irradiation (UVGI) on N95 Respirator Filtration Performance and Structural Integrity
    Lindsley, William G.
    Martin, Stephen B., Jr.
    Thewlis, Robert E.
    Sarkisian, Khachatur
    Nwoko, Julian O.
    Mead, Kenneth R.
    Noti, John D.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2015, 12 (08) : 509 - 517
  • [22] Design, Implementation, and Evaluation of an N95 Respirator Decontamination and Reuse Program for Healthcare Workers During the COVID-19 Pandemic
    Ntiforo, Corrie A.
    McDougal, April N.
    DeMaet, Mary Ann
    Mayer-Diaz, Malissa A.
    Newton, Je T'Aime M.
    Dacso, Matthew M.
    HEALTH SECURITY, 2023, 21 (01) : 11 - 21
  • [23] Impact of extended use and decontamination with vaporized hydrogen peroxide on N95 respirator fit
    Lieu, Anthony
    Mah, Jordan
    Zanichelli, Veronica
    Exantus, Rose Carmel
    Longtin, Yves
    AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (12) : 1457 - 1461
  • [24] Efficacy and Safety of Weekly Ultraviolet Germicidal Irradiation for the Reuse of N95 Filtering Respirators
    Nakamoto, Keitaro
    Saraya Sr, Takeshi
    Ishikawa, Narishige
    Mikura, Sunao
    Yoshida, Yuki
    Fukukawa, Naokatsu
    Taneoka, Takako
    Shimasaki, Teppei
    Kurai, Daisuke
    Ishii, Haruyuki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [25] Determination of the optimal time for N95 respirator for aerosol infection control
    Du, Jian
    Zhang, Lijie
    Liu, Yuhong
    Shu, Wei
    Ma, Yan
    Gao, Jingtao
    Li, Liang
    MEDICINE, 2020, 99 (50) : E23709
  • [26] Incidence of Fit Test Failure During N95 Respirator Reuse and Extended Use
    Wang, Ralph C.
    Degesys, Nida F.
    Fahimi, Jahan
    Jin, Chengshi
    Rosenthal, Efrat
    Lazar, Ann A.
    Yaffee, Anna Q.
    Peterson, Susan
    Rothmann, Richard E.
    Jones, Courtney M. C.
    Tolia, Vaishal
    Shah, Manish N.
    Raven, Maria C.
    JAMA NETWORK OPEN, 2024, 7 (01)
  • [27] Decontamination and reuse of N95 filtering facemask respirators: A systematic review of the literature
    Rodriguez-Martinez, Carlos E.
    Sossa-Briceno, Monica P.
    Cortes, Jorge A.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (12) : 1520 - 1532
  • [28] Scalable, effective, and rapid decontamination of SARS-CoV-2 contaminated N95 respirators using germicidal ultraviolet C (UVC) irradiation device
    Rathnasinghe, Raveen
    Karlicek, Robert F.
    Schotsaert, Michael
    Koffas, Mattheos
    Arduini, Brigitte L.
    Jangra, Sonia
    Wang, Bowen
    Davis, Jason L.
    Alnaggar, Mohammed
    Costa, Anthony
    Vincent, Richard
    Garcia-Sastre, Adolfo
    Vashishth, Deepak
    Balchandani, Priti
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [29] Scalable, effective, and rapid decontamination of SARS-CoV-2 contaminated N95 respirators using germicidal ultraviolet C (UVC) irradiation device
    Raveen Rathnasinghe
    Robert F. Karlicek
    Michael Schotsaert
    Mattheos Koffas
    Brigitte L. Arduini
    Sonia Jangra
    Bowen Wang
    Jason L. Davis
    Mohammed Alnaggar
    Anthony Costa
    Richard Vincent
    Adolfo García-Sastre
    Deepak Vashishth
    Priti Balchandani
    Scientific Reports, 11
  • [30] Validation of N95 Filtering Facepiece Respirator Decontamination Methods Available at a Large University Hospital
    Wigginton, Krista R.
    Arts, Peter J.
    Clack, Herek L.
    Fitzsimmons, William J.
    Gamba, Mirko
    Harrison, Katherine R.
    LeBar, William
    Lauring, Adam S.
    Li, Lucinda
    Roberts, William W.
    Rockey, Nicole C.
    Torreblanca, Jania
    Young, Carol
    Anderegg, Loic G.
    Cohn, Amy M.
    Doyle, John M.
    Meisenhelder, Cole M.
    Raskin, Lutgarde
    Love, Nancy G.
    Kaye, Keith S.
    OPEN FORUM INFECTIOUS DISEASES, 2021, 8 (02):