On the numerical investigation of cardiovascular balloon-expandable stent using finite element method

被引:28
|
作者
Azaouzi, M. [1 ]
Makradi, A. [1 ]
Petit, J. [2 ]
Belouettar, S. [1 ]
Polit, O. [2 ]
机构
[1] Ctr Rech Publ Henri Tudor, Adv Mat & Struct Dept, L-4002 Esch Sur Alzette, Luxembourg
[2] Univ Paris Ouest, LEME, F-92410 Ville Davray, France
关键词
Cardiovascular stent; Finite element analysis; Numerical simulation; Fatigue life prediction; Goodman diagram; FATIGUE; SIZE; COMPONENTS; BEHAVIOR; FRACTURE; DESIGN; STRUTS;
D O I
10.1016/j.commatsci.2013.05.043
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present paper shows an effective methodology which is based on Finite Element Analysis (FEA) for the fatigue life prediction (FLP) of a Balloon-Expandable (BE) stent made of stainless steel material (AISI316L). BE stent is a tubular, often mesh-like, structure which is expanded inside a diseased (stenosed) artery segment to restore blood flow and keep the vessel open following angioplasty. With design lives of 10-15 years, fatigue life prediction of these devices is critical for the designer, as fatigue failure may occur after deployment inside the blood vessel due to the heart beating (typically 4 x 10(7) cycles/year). Therefore, it is crucial to study the effect of stenting conditions and stent design on the fatigue life of BE stents. The objective of this paper is to provide quantitative measures of the stent's stress amplitude and mean stress which are generated by the cardiac pulse pressure. This allows prediction of the device's life and optimization of stent designs. In this paper, numerical investigations were conducted using an effective approach based on the well-known stress-based Goodman Diagram (GD) for the FLP of a given stent design. It has been demonstrated that the percentage of artery's expansion as well as the dimensions of the struts (the fundamental structural unit that forms the stent), have both an impact on the fatigue behavior after stent deployment. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:326 / 335
页数:10
相关论文
共 50 条
  • [1] Computational modeling of balloon-expandable stent deployment in coronary artery using the finite element method
    Umer, Muhammad
    Ali, Murtaza Najabat
    Mubashar, Aamir
    Mir, Mariam
    RESEARCH REPORTS IN CLINICAL CARDIOLOGY, 2019, 10 : 43 - 56
  • [2] Finite element analysis of the implantation of a balloon-expandable stent in a stenosed artery
    Liang, DK
    Yang, DZ
    Qi, M
    Wang, WQ
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (03) : 314 - 318
  • [3] Numerical investigations of the structural behavior of a balloon expandable stent design using finite element method
    Azaouzi, M.
    Makradi, A.
    Belouettar, S.
    COMPUTATIONAL MATERIALS SCIENCE, 2013, 72 : 54 - 61
  • [4] On the finite element modelling of balloon-expandable stents
    Jua, Feng
    Xia, Zihui
    Sasaki, Katsuhiko
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2008, 1 (01) : 86 - 95
  • [5] Finite element analysis of balloon-expandable coronary stent deployment: Influence of angioplasty balloon configuration
    Martin, David
    Boyle, Fergal
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2013, 29 (11) : 1161 - 1175
  • [6] Numerical study of the uniformity of balloon-expandable stent deployment
    Mortier, P.
    De Beule, M.
    Carlier, S. G.
    Van Impe, R.
    Verhegghe, B.
    Verdonck, P.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02):
  • [7] Finite Element Analysis of a Balloon-Expandable Stent and Superior Mesenteric Arterial Wall Interaction
    Knowles, Martyn
    Welch, Tre R.
    Timaran, Carlos H.
    Valentine, R. James
    Chuong, Cheng Jen
    Eberhart, Robert C.
    Reddy, Surendranath Veeram
    Nugent, Alan
    Forbess, Joseph A.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (06) : 1722 - 1723
  • [8] BALLOON-EXPANDABLE INTRAVASCULAR STENT
    PALMAZ, JC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 150 (06) : 1263 - 1269
  • [9] BALLOON-EXPANDABLE STENT OCCLUDER
    MOSS, JG
    LABORDE, JC
    CLEM, MF
    RIVERA, FJ
    ENCARNACION, CE
    LUTZ, JD
    RADIOLOGY, 1992, 185 : 134 - 134
  • [10] On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method
    Gervaso, Francesca
    Capelli, Claudio
    Petrini, Lorenza
    Lattanzio, Simone
    Di Virgilio, Luca
    Migliavacca, Francesco
    JOURNAL OF BIOMECHANICS, 2008, 41 (06) : 1206 - 1212