Computational Fluid Dynamics Simulations of Contrast Agent Bolus Dispersion in a Coronary Bifurcation: Impact on MRI-Based Quantification of Myocardial Perfusion

被引:8
|
作者
Schmidt, Regine [1 ]
Graafen, Dirk [1 ]
Weber, Stefan [1 ]
Schreiber, Laura M. [1 ]
机构
[1] Johannes Gutenberg Univ Mainz, Univ Med Ctr, Dept Radiol, Sect Med Phys, D-55131 Mainz, Germany
关键词
POSITRON-EMISSION-TOMOGRAPHY; VESSEL WALL ELASTICITY; BLOOD-FLOW; MAGNETIC-RESONANCE; BYPASS GRAFT; MODEL; ADENOSINE; PARAMETERS; RESISTANCE; VELOCITY;
D O I
10.1155/2013/513187
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Contrast-enhanced first-pass magnetic resonance imaging (MRI) in combination with a tracer kinetic model, for example, MMID4, can be used to determine myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Typically, the arterial input function (AIF) required for this methodology is estimated from the left ventricle (LV). Dispersion of the contrast agent bolus might occur between the LV and the myocardial tissue. Negligence of bolus dispersion could cause an error in MBF determination. The aim of this study was to investigate the influence of bolus dispersion in a simplified coronary bifurcation geometry including one healthy and one stenotic branch on the quantification of MBF and MPR. Computational fluid dynamics (CFD) simulations were combined with MMID4. Different inlet boundary conditions describing pulsatile and constant flows for rest and hyperemia and differing outflow conditions have been investigated. In the bifurcation region, the increase of the dispersion was smaller than inside the straight vessels. A systematic underestimation of MBF values up to -16.1% for pulsatile flow and an overestimation of MPR up to 7.5% were found. It was shown that, under the conditions considered in this study, bolus dispersion can significantly influence the results of quantitative myocardial MR-perfusion measurements.
引用
收藏
页数:13
相关论文
共 43 条
  • [41] Velocity Measurement in Carotid Artery: Quantitative Comparison of Time-Resolved 3D Phase-Contrast MRI and Image-based Computational Fluid Dynamics
    Sarrami-Foroushani, Ali
    Esfahany, Mohsen Nasr
    Moghaddam, Abbas Nasiraei
    Rad, Hamidreza Saligheh
    Firouznia, Kavous
    Shakiba, Madjid
    Ghanaati, Hossein
    Wilkinson, Iain David
    Frangi, Alejandro Federico
    IRANIAN JOURNAL OF RADIOLOGY, 2015, 12 (04)
  • [42] The influence of flow distribution strategy for the quantification of pressure- and wall shear stress-derived parameters in the coronary artery: A CTA-based computational fluid dynamics analysis
    Shi, Yibing
    Zheng, Jin
    Zhang, Ying
    Sun, Quanlin
    Shen, Jinhua
    Gao, Yongguang
    Sun, Jingxi
    Yang, Ning
    Zhou, Xuanxuan
    Li, Suqing
    Weir-McCall, Jonathan R.
    Xia, Ping
    Teng, Zhongzhao
    JOURNAL OF BIOMECHANICS, 2023, 161
  • [43] In Vitro Validation of Flow Measurement With Phase Contrast MRI at 3 Tesla Using Stereoscopic Particle Image Velocimetry and Stereoscopic Particle Image Velocimetry-Based Computational Fluid Dynamics
    Khodarahmi, Iman
    Shakeri, Mostafa
    Kotys-Traughber, Melanie
    Fischer, Stefan
    Sharp, M. Keith
    Amini, Amir A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (06) : 1477 - 1485