Measurement of glucose concentrations of potato extract using a blood glucose test strip

被引:0
|
作者
Misener, GC
Gerber, WA
Tai, GCC
Embleton, EJ
机构
来源
CANADIAN AGRICULTURAL ENGINEERING | 1996年 / 38卷 / 01期
关键词
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A blood glucose test strip integrated into a modified circuit with a user-designed converter was evaluated as an efficient means to measure the amount of glucose in potato extract. The amount of glucose in potato extract was established using the HPLC method and the experimental monitor. The resulting output from the enzymatic reaction of the test strip was observed to be linear for potato extract with glucose concentrations from 5 to 50 mmol/L. A regression equation was developed using data from four replications of ten varieties of potatoes having different sugar levels. Determinations of glucose concentration with the experimental monitor and YSI on potato extract compared favourably (r = 0.87).
引用
收藏
页码:59 / 62
页数:4
相关论文
共 50 条
  • [41] Measurement of low glucose concentrations using a microelectrochemical enzyme transistor
    Bartlett, PN
    Wang, JH
    James, W
    ANALYST, 1998, 123 (02) : 387 - 392
  • [42] Reliable blood glucose measurement with the APEC glucose analyser
    Heinemann, L
    Weyer, C
    Stoffels, M
    Schaden, U
    Heise, T
    DIABETOLOGIA, 1997, 40 : 1400 - 1400
  • [43] Blood Glucose Measurement by Means of Glucoseoxidase-based Blood Glucose Test Strips - Clinical Relevance of Laboratory Concerns
    Pfuetzner, A.
    Kalasauske, U.
    Thome, N.
    DIABETES STOFFWECHSEL UND HERZ, 2022, 31 (05): : 285 - 288
  • [44] ENZYME STRIP METHOD OF BLOOD GLUCOSE DETERMINATION
    HOLLISTER, LE
    HELMKE, E
    WRIGHT, A
    DIABETES, 1966, 15 (09) : 691 - +
  • [45] A NEW VISUAL BLOOD-GLUCOSE STRIP
    CLARK, AJL
    BUNDOCK, J
    NEWALL, RG
    KEEN, H
    DIABETOLOGIA, 1982, 23 (05) : 466 - 466
  • [46] ENZYME-STRIP ESTIMATION OF BLOOD GLUCOSE
    CHRYSSOCHOOS, TJ
    WEISENFE.S
    DIABETES, 1965, 14 (07) : 452 - +
  • [47] RELATIVE CONSTANCY OF GLUCOSE AND INSULIN CONCENTRATIONS IN BLOOD OF PIGS UNDER CONDITIONS OF INTRAVENOUS GLUCOSE-TOLERANCE TEST
    SCHULKE, B
    TEGELER, G
    KORSCHEWITZ, I
    SCHROTER, C
    MONATSHEFTE FUR VETERINARMEDIZIN, 1979, 34 (09): : 340 - 343
  • [48] Influence of glucose test strip design on the accuracy of test results
    Velazquez, FR
    Wright, L
    Ko, VT
    DIABETES, 1999, 48 : A349 - A349
  • [49] GLUCOSE MEASUREMENT IN DILUTED BLOOD
    SCHELLER, FW
    PFEIFFER, D
    HINTSCHE, R
    DRANSFELD, I
    NENTWIG, J
    BIOMEDICA BIOCHIMICA ACTA, 1989, 48 (11-12) : 891 - 896
  • [50] MEASUREMENT OF BLOOD-GLUCOSE
    BURRIN, JM
    PRICE, CP
    ANNALS OF CLINICAL BIOCHEMISTRY, 1985, 22 (JUL) : 327 - 342