Development of an immobilization and detection method of Enterobacter sakazakii from powdered infant formula

被引:31
|
作者
Zhou, Yanhong [1 ,2 ,3 ]
Wu, Qingping [1 ]
Xu, Xiaoke [1 ]
Yang, Xiaojuan [1 ]
Ye, Yingwang [1 ,3 ,4 ]
Zhang, Jumei [1 ]
机构
[1] Guandong Inst Microbiol, Guangdong Prov Key Lab Microbiol Culture Collect, Guangzhou 510070, Guangdong, Peoples R China
[2] Chinese Acad Sci, Wuhan Inst Virol, Wuhan 430071, Peoples R China
[3] Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
[4] Chinese Acad Sci, S China Sea Inst Oceanol, Guangzhou 510301, Guangdong, Peoples R China
关键词
Enterobacter sakazakii; immobilization; duplex PCR; powdered infant formula;
D O I
10.1016/j.fm.2008.04.001
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Enterobacter sakazakii is an emerging opportunistic pathogen that is associated with rare but life-threatening cases of meningitis, necrotizing enterocolitis, and sepsis in premature and full-term infants. In the present study, a procedure was developed for immobilization of E. sakazakii with zirconium hydroxide coupled with detection by a species-specific duplex PCR, based on 16s-23s rDNA internal transcribed spacer (ITS) and ompA gene. Specificity of duplex PCR was tested against two-type strains, six isolates of E. sakazakii and other eight non-E. sakazakii species. When pure culture of E. sakazakii was used for immobilization, total recovery rate ranged from 79.4% to 99.6% of input bacteria, and the detection limit of duplex PCR was 3 x 10(5) CFU/ml. Different levels of E. sakazakii were inoculated into 90 ml reconstituted powdered infant formula (PIF), and detection limit of duplex PCR was 3 x 10(0) CFU/ ml with 24-30h enrichment after immobilization. When the experiment was performed in the presence of 10(2) CFU/ml Salmonella typhimurium, the detection limit of duplex PCR was not affected after enrichment. Seven out of 13 commercial PIF were detected positive by duplex PCR after immobilization, while only three were positive by biological methods. This study demonstrates that the combination of immobilization method with duplex PCR is easy, rapid, and efficient, and may have applications for the detection of E. sakazakii in more PIF samples. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:648 / 652
页数:5
相关论文
共 50 条
  • [31] Temperature effects on the growth of enterobacter Sakazakii in powdered infant formulas
    Chan, GM
    PEDIATRIC RESEARCH, 2004, 55 (04) : 385A - 385A
  • [32] Individual cell lag time distributions of Cronobacter (Enterobacter sakazakii) and impact of pooling samples on its detection in powdered infant formula
    Miled, Rabeb Bennour
    Guillier, Laurent
    Neves, Sandra
    Augustin, Jean-Christophe
    Colin, Pierre
    Besse, Nathalie Gnanou
    FOOD MICROBIOLOGY, 2011, 28 (04) : 648 - 655
  • [33] Response to 'On the risk of Enterobacter sakazakii in infant milk formula'
    Iversen, C
    Forsythe, S
    TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2004, 15 (02) : 101 - 102
  • [34] Inactivation of Enterobacter sakazakii in reconstituted infant formula by monocaprylin
    Nair, MKM
    Joy, J
    Venkitanarayanan, KS
    JOURNAL OF FOOD PROTECTION, 2004, 67 (12) : 2815 - 2819
  • [35] Growth and survival of Enterobacter sakazakii in human breast milk with and without fortifiers as compared to powdered infant formula
    Lenati, Raquel F.
    O'Connor, Deborah L.
    Hebert, Karine C.
    Farber, Jeffrey M.
    Pagotto, Franco J.
    INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2008, 122 (1-2) : 171 - 179
  • [36] Incidence, survival, and growth of Enterobacter sakazakii in infant formula
    NazarowecWhite, M
    Farber, JM
    JOURNAL OF FOOD PROTECTION, 1997, 60 (03) : 226 - 230
  • [37] Thermal inactivation of Enterobacter sakazakii in rehydrated infant formula
    Edelson-Mammel, SG
    Buchanan, RL
    JOURNAL OF FOOD PROTECTION, 2004, 67 (01) : 60 - 63
  • [38] Specific detection of Cronobacter sakazakii in powdered infant formula using ssDNA aptamer
    Kim, Hye Ri
    Kim, Myunghee
    Kim, Byoung Chan
    ANALYST, 2021, 146 (11) : 3534 - 3542
  • [39] Powder Infant Formula Milk Contaminated with Enterobacter sakazakii
    Oonaka, Kenji
    Furuhata, Katsunori
    Hara, Motonobu
    Fukuyama, Masafumi
    JAPANESE JOURNAL OF INFECTIOUS DISEASES, 2010, 63 (02) : 103 - 107
  • [40] SENSITIVE AND RAPID DETECTION OF ENTEROBACTER SAKAZAKII IN INFANT FORMULA BY LOOP-MEDIATED ISOTHERMAL AMPLIFICATION METHOD
    Liu, Chao
    Zheng, Wenjie
    Zhang, Hongwei
    Hou, Yanmei
    Liu, Yin
    JOURNAL OF FOOD SAFETY, 2009, 29 (01) : 83 - 94