Different impact factors for accurate oscillometric blood pressure measurement between sinus rhythm and atrial fibrillation

被引:8
|
作者
Xie, Feng [1 ]
Xu, Jinsong [2 ]
Liu, Huan [2 ]
Li, Xiaozhong [2 ]
Wu, Yanqing [2 ]
Su, Hai [2 ]
机构
[1] JiangXi Pingxiang Peoples Hosp, Dept Cardiovasc Med, Pingxiang, Peoples R China
[2] Nanchang Univ, Affiliated Hosp 2, Dept Cardiovasc Med, Nanchang, Jiangxi, Peoples R China
关键词
AGE;
D O I
10.1038/s41371-021-00512-9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This study was conducted to evaluate whether the impact factor on the accuracy of oscillometric blood pressure (BP) is different between the patients with atrial affiliation (AF) and sinus rhythm (SR). This study included 124 AF patients and 98 SR patients who underwent coronary arteriography. Upper arm oscillometric and intro-aortic BP were simultaneously measured three times, and the averages were recorded as final values, respectively. The difference between oscillometric and intro-aortic BP was recorded as delta BP. For reducing the influence of baseline BP on delta BP, a percentage difference (PD-BP) was calculated with the formula: PD-BP = delta BP/intro-aortic BP x 100%. The oscillometric SBP and DBP levels slightly underestimated intro-aortic BP (by 2.2/1.6 mmHg) in the SR group, but significantly underestimated (by 5.8/4.8 mmHg) in the AF group. Age was negatively correlated with delta SBP and positively with delta DBP in SR patients, but not correlated in AF patients. Otherwise, ventricular rate (VR) was negatively correlated with delta SBP or delta DBP in AF, which indicated that the accuracy of oscillometric BP declined as the VR increased. With intro-aortic BP as reference, the accuracy of oscillometric BP in AF patients is lower than SR patients. Meanwhile, age may impact the oscillometric BP accuracy in SR patients, but VR may impact that in AF patients.
引用
收藏
页码:785 / 790
页数:6
相关论文
共 50 条
  • [1] Different impact factors for accurate oscillometric blood pressure measurement between sinus rhythm and atrial fibrillation
    Feng Xie
    Jinsong Xu
    Huan Liu
    Xiaozhong Li
    Yanqing Wu
    Hai Su
    Journal of Human Hypertension, 2021, 35 : 785 - 790
  • [2] Performance of inflationary oscillometric blood pressure measurement in the presence of atrial fibrillation: comparison to sinus rhythm
    Maki, Yuichi
    Sakamoto, Yasumasa
    Abe, Risa
    Morozumi, Kohei
    Toyoda, Daisuke
    Kotake, Yoshifumi
    JOURNAL OF ANESTHESIA, 2025, 39 (02) : 292 - 298
  • [3] Accuracy of oscillometric blood pressure measurement in atrial fibrillation
    Feenstra, Rudolf K.
    Allaart, Cor P.
    Berkelmans, Gijs F. N.
    Westerhof, Berend E.
    Smulders, Yvo M.
    BLOOD PRESSURE MONITORING, 2018, 23 (02) : 59 - 63
  • [4] The impact of atrial fibrillation on accuracy of oscillometric blood pressure measurement: effect of ventricular rate
    Feng Xie
    Jingsong Xu
    Ling-lin Xia
    Xiao Luo
    Zhenzhen Jiang
    Yanqing Wu
    Hai Su
    Hypertension Research, 2020, 43 : 518 - 524
  • [5] The impact of atrial fibrillation on accuracy of oscillometric blood pressure measurement: effect of ventricular rate
    Xie, Feng
    Xu, Jingsong
    Xia, Ling-lin
    Luo, Xiao
    Jiang, Zhenzhen
    Wu, Yanqing
    Su, Hai
    HYPERTENSION RESEARCH, 2020, 43 (06) : 518 - 524
  • [6] Impact of Atrial Fibrillation on the Accuracy of Oscillometric Blood Pressure Monitoring
    Pagonas, Nikolaos
    Schmidt, Sven
    Eysel, Joerg
    Compton, Friederike
    Hoffmann, Clemens
    Seibert, Felix
    Hilpert, Justus
    Tschoepe, Carsten
    Zidek, Walter
    Westhoff, Timm H.
    HYPERTENSION, 2013, 62 (03) : 579 - 584
  • [7] Does Atrial Fibrillation Affect the Automated Oscillometric Blood Pressure Measurement?
    Stergiou, George S.
    Kollias, Anastasios
    Karpettas, Nikos
    HYPERTENSION, 2013, 62 (05) : E37 - E37
  • [8] Challenges in oscillometric blood pressure measurement in atrial fibrillation: looking for practical solutions
    Narkiewicz, Krzysztof
    Kjeldsen, Sverre E.
    Burnier, Michel
    Oparil, Suzanne
    BLOOD PRESSURE, 2018, 27 (01) : 1 - 2
  • [9] Response to Does Atrial Fibrillation Affect the Automated Oscillometric Blood Pressure Measurement?
    Pagonas, Nikolaos
    Westhoff, Timm H.
    HYPERTENSION, 2013, 62 (05) : E38 - E38
  • [10] Preliminary study on detection of atrial fibrillation during oscillometric blood pressure measurement
    Meza, M.
    2015 8TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2015, : 1174 - 1178