Reducing ExacTrac intrafraction imaging uncertainty for prostate stereotactic body radiotherapy using a pre-treatment CBCT

被引:2
|
作者
Jordan, Barry [1 ]
Munoz, Luis [1 ]
Colyer, Christopher [1 ]
机构
[1] St Andrews Hosp Oncol, GenesisCare, Adelaide, SA, Australia
关键词
ExacTrac; CBCT; SBRT; Intrafraction; Prostate; IGRT; BEAM COMPUTED-TOMOGRAPHY; GUIDED RADIOTHERAPY; RADIATION-THERAPY; ORGAN MOTION; MULTIINSTITUTIONAL CONSORTIUM; GEOMETRIC ACCURACY; RADIOPAQUE MARKERS; IMPLANTED MARKERS; FIDUCIAL MARKERS; CANCER;
D O I
10.1007/s13246-022-01121-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study evaluated the intrafractional auto-matching uncertainties of prostate-implanted fiducial markers when using the ExacTrac v6.5 (Brainlab, Feldkirchen, Germany) X-ray stereoscopic system. A customised phantom with 3 implanted gold seeds was initially positioned at the isocentre using a cone beam CT (CBCT) prior to intrafractional imaging. Progressive offsets were applied to the phantom in all six directions (3 translational, 3 rotational) of 0 mm, 1 mm, 2 mm, 0 degrees, 1 degrees and 2 degrees. Subsequently, the ability of the ExacTrac image-matching functions to detect and correct these offsets was tested. For comparison, this procedure was repeated, but without a CBCT for pre-treatment positioning. The auto-matching uncertainties when a CBCT was introduced into the workflow were significantly reduced, and overall, the auto-matching statistics using the implanted marker (seeds) matching function was found to be more precise than the bony anatomy function in-phantom. The total standard deviations for the translational shifts using the implanted marker and bony anatomy functions respectively were 0.1 mm and 0.3 mm vertically, 0.1 mm and 0.3 mm longitudinally, and 0.1 mm and 0.4 mm laterally. The standard deviations for the rotational shifts using the implanted marker and bony anatomy matching functions respectively were 0.2 degrees and 1.2 degrees for the yaw (angle vert), 0.3 degrees and 1.1 degrees for the pitch (angle long), and 0.2 degrees and 1.2 degrees for the roll (angle lat) directions. The reduced uncertainties from introducing a CBCT for initial localisation resulted in decreased probability of inhibits due to false positives during treatment.
引用
收藏
页码:547 / 558
页数:12
相关论文
共 50 条
  • [1] Reducing ExacTrac intrafraction imaging uncertainty for prostate stereotactic body radiotherapy using a pre-treatment CBCT
    Barry Jordan
    Luis Muñoz
    Christopher Colyer
    Physical and Engineering Sciences in Medicine, 2022, 45 : 547 - 558
  • [2] An assessment of the ExacTrac intrafraction imaging capabilities for flattening filter free prostate stereotactic body radiotherapy
    Rijken, James
    Sidhom, Mark
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (03) : 849 - 855
  • [3] An assessment of the ExacTrac intrafraction imaging capabilities for flattening filter free prostate stereotactic body radiotherapy
    James Rijken
    Mark Sidhom
    Physical and Engineering Sciences in Medicine, 2020, 43 : 849 - 855
  • [4] Intrafraction Motion Management of CBCT Guided Online Stereotactic Adaptive Prostate Cancer Radiotherapy
    Huang, Y.
    Zhao, B.
    Noora, B. S.
    Gallagher, I.
    Doemer, A. J.
    Thind, K.
    Feldman, A. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E138 - E139
  • [5] Magnetic Resonance Imaging Guidance Mitigates the Effects of Intrafraction Prostate Motion During Stereotactic Body Radiotherapy for Prostate Cancer
    Hegde, John V.
    Cao, Minsong
    Yu, Victoria Y.
    Kishan, Amar U.
    Shaverdian, Narek
    Lamb, James
    Steinberg, Michael L.
    CUREUS, 2018, 10 (04):
  • [6] Evaluation of Intrafraction Motion During Spine Stereotactic Body Radiotherapy Using Pre and Post Treatment Cone Beam Computed Tomography
    Magnelli, A.
    Qi, P.
    Balik, S.
    Zhuang, T.
    Chao, S.
    Suh, J.
    Xia, P.
    MEDICAL PHYSICS, 2019, 46 (06) : E333 - E333
  • [7] Pre-treatment Simulation of Target Motion for Frameless Intracranial Stereotactic Radiosurgery Treatments using the Novalis Exactrac System
    Opp, D.
    Feygelman, V.
    Sarangkasiri, S.
    Walker, L.
    Brem, S.
    Chinnaiyan, P.
    Forster, K.
    Yu, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S602 - S602
  • [8] Predicting intrafraction displacement of the prostate during a five-fraction radiotherapy regimen: Implications for stereotactic body radiotherapy
    Quon, H. C.
    Loblaw, D. A.
    Cheung, P.
    Cesta, A.
    Holden, L.
    Tang, C. I.
    Pang, G.
    Morton, G.
    Mamedov, A.
    Deabreu, A.
    JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (07)
  • [9] Exactrac X-ray imaging during stereotactic radiotherapy of bone metastases. Comparison with kV-CBCT
    Henni, A. Hadj
    Thureau, S.
    Colard, E.
    Bulot, G.
    Roge, M.
    Hanzen, C.
    Gensanne, D.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1487 - S1488
  • [10] Clinical Experience on the Treatment of Lung and Liver Lesions with Stereotactic Body Radiotherapy using a Novalis Exactrac Adaptive Gating Technique
    Rubio, M. C.
    Hernando, O.
    Sanchez, E.
    Garcia-Aranda, M.
    Valero, J.
    Lopez, M.
    Zucca, D.
    Perez Moreno, J. M.
    Fernandez Leton, P.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S16 - S16