Exactrac X-ray imaging during stereotactic radiotherapy of bone metastases. Comparison with kV-CBCT

被引:0
|
作者
Henni, A. Hadj [1 ]
Thureau, S. [1 ]
Colard, E. [1 ]
Bulot, G. [1 ]
Roge, M. [1 ]
Hanzen, C. [1 ]
Gensanne, D. [1 ]
机构
[1] Ctr Henri Becquerel, Radiotherapy, Rouen, France
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-1761
引用
收藏
页码:S1487 / S1488
页数:2
相关论文
共 50 条
  • [1] ExacTrac X-Ray 6D Imaging During Stereotactic Body Radiation Therapy of Spinal and Nonspinal Metastases
    Henni, Ahmed Hadj
    Gensanne, David
    Bulot, Guillaume
    Roge, Maximilien
    Mallet, Romain
    Colard, Elyse
    Daras, Marie
    Hanzen, Chantal
    Thureau, Sebastien
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [2] ExacTrac X-Ray 6D Imaging During Stereotactic Body Radiation Therapy of Spinal and Nonspinal Metastases
    Henni, Ahmed Hadj
    Gensanne, David
    Bulot, Guillaume
    Roge, Maximilien
    Mallet, Romain
    Colard, Elyse
    Daras, Marie
    Hanzen, Chantal
    Thureau, Sebastien
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2023, 22
  • [3] Setup error and residual error analysis of ExacTrac X-ray image guidance system in stereotactic radiotherapy for brain metastases
    Hua, Wei
    Xu, Bing
    Zhang, Xianwen
    Zhang, Xizhi
    Chen, Tingting
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (04)
  • [4] Bone heterogeneity in kV x-ray radiotherapy
    Chow, J.
    Grigorov, G.
    MEDICAL PHYSICS, 2012, 39 (07) : 4628 - 4628
  • [5] Comparison of Inter-Fraction Setup Uncertainty of Two Commercially- Available, Cranial Immobilization Masks Using KV-CBCT and ExacTrac® Imaging Systems
    Nayebi, N.
    Gutierrez, A.
    Papanikolaou, N.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Analysis of application X-ray radiation up to 250 kV for stereotactic radiosurgery and radiotherapy
    Kumahov, M.
    Kotkin, A.
    Gorlachev, G.
    EJC SUPPLEMENTS, 2005, 3 (02): : 414 - 414
  • [7] Comparison of Varian TrueBeam Cone-Beam CT and BrainLab ExacTrac X-Ray for Cranial Radiotherapy
    Li, J.
    Shi, W.
    Andrews, D.
    Werner-Wasik, M.
    Lu, B.
    Yu, Y.
    Dicker, A.
    Liu, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3415 - 3415
  • [8] 4D-CBCT (Symmetry Elekta X-ray) for ITV generation in thoracic stereotactic radiotherapy
    Marcucci, S.
    Caravatta, L.
    Rosa, C.
    Nuzzo, M.
    Di Tommaso, M.
    Taraborrelli, M.
    Di Carlo, C.
    Di Guglielmo, F. C.
    Gasparini, L.
    Adorante, N.
    Genovesi, D.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1676 - S1677
  • [9] An algorithm for kilovoltage x-ray dose calculations with applications in kV-CBCT scans and 2D planar projected radiographs
    Pawlowski, Jason M.
    Ding, George X.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (08): : 2041 - 2058
  • [10] 200 kV x-ray source for radiotherapy and imaging: preliminary results and discussion
    Stalbaum, Tyler
    Boyd, Douglas
    Weil, Michael
    Chen, Hong
    Plies, Michael
    Song, Samuel
    Ziskin, Vitaliy
    Bazalova-Carter, Magdalena
    Boone, John
    Daly, Megan
    Partain, Larry
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312