Additive Manufacturing of Ankle-Foot Orthosis with Predefined Ankle Stiffness-A Case Report

被引:2
|
作者
Vasiliauskaite, Egle [1 ,2 ]
Van Paepegem, Wim [3 ]
Deckers, Jan Patrick [4 ]
Vermandel, Miguel
Forward, Malcolm [1 ,2 ]
Plasschaert, Frank [1 ]
机构
[1] Univ Ghent, Dept Phys Med & Orthopaed Surg, C Heymanslaan 10,P5, B-9000 Ghent, Belgium
[2] Univ Ghent, Dept Elect & Informat Syst, Ghent, Belgium
[3] Univ Ghent, Dept Mat Sci & Engn, Ghent, Belgium
[4] V GO Grp NV, Wetteren, Belgium
基金
芬兰科学院;
关键词
AFO; gait; printing; drop foot; personalized; CEREBRAL-PALSY; GAIT; CHILDREN; WALKING; MODEL;
D O I
10.1097/JPO.0000000000000336
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: The success of orthotic interventions depends on how well an individual patient's needs are identified and addressed. In this prospective study, we addressed the following question: Is it possible to additively manufacture an ankle-foot orthosis (AFO) with predefined ankle stiffness that would decrease excessive plantarflexion in the dropfoot gait? Materials and Methods: A child with unilateral drop foot was recruited for this study and took part in three gait assessments. In the first gait assessment, the "optimal" AFO stiffness was determined using a hinged AFO with adjustable ankle stiffness. A leafspring-type AFO with predefined optimal ankle stiffness was then virtually designed and additively manufactured. The impact of this orthosis on the patient's gait before and after 6 weeks of acclimatization period was evaluated in the second and the third gait assessments, respectively. Results: A hinged orthosis with an ankle stiffness of 0.009 N center dot m center dot deg(-1)center dot kg(-1) was deemed to be the optimal for the study patient. The ankle stiffness of the additively manufactured AFO was 0.008 N center dot m center dot deg(-1)center dot kg(-1). This orthosis decreased patient's excessive plantarflexion, but its impact was moderately inferior compared with that of the optimal hinged orthosis. Conclusions: Despite having the same ankle stiffness, hinged AFO and leaf-spring AFO did not produce the same gait pattern. Therefore, to prescribe an optimal AFO, a better understanding of subject-AFO interaction in walking is needed.
引用
收藏
页码:310 / 318
页数:9
相关论文
共 50 条
  • [41] A Review of Additive Manufacturing Studies for Producing Customized Ankle-Foot Orthoses
    Silva, Rui
    Veloso, Antonio
    Alves, Nuno
    Fernandes, Cristiana
    Morouco, Pedro
    [J]. BIOENGINEERING-BASEL, 2022, 9 (06):
  • [42] A Backstepping Control Design for An Active Ankle-Foot Orthosis
    Savas, Yagiz
    Kirtas, Oguzhan
    Basturk, Halil
    Samur, Evren
    [J]. 2017 IEEE 56TH ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2017,
  • [43] Fuel Efficiency of a Portable Powered Ankle-Foot Orthosis
    Boes, Morgan K.
    Islam, Mazharul
    Li, Yifan David
    Hsiao-Wecksler, Elizabeth T.
    [J]. 2013 IEEE 13TH INTERNATIONAL CONFERENCE ON REHABILITATION ROBOTICS (ICORR), 2013,
  • [44] Experimental and computational analysis of composite ankle-foot orthosis
    Zou, Dequan
    He, Tao
    Dailey, Michael
    Smith, Kirk E.
    Silva, Matthew J.
    Sinacore, David R.
    Mueller, Michael J.
    Hastings, Mary K.
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2014, 51 (10): : 1525 - 1535
  • [45] The effect of rotational speed on ankle-foot orthosis properties
    Totah, Deema
    Barton, Kira
    Gates, Deanna H.
    [J]. JOURNAL OF BIOMECHANICS, 2021, 123
  • [46] Neuromechanical adaptation to hopping with an elastic ankle-foot orthosis
    Ferris, DP
    Bohra, ZA
    Lukos, JR
    Kinnaird, CR
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2006, 100 (01) : 163 - 170
  • [47] Experimental Evaluation of a Portable Powered Ankle-Foot Orthosis
    Shorter, Kenneth A.
    Li, Yifan
    Morris, Emily A.
    Kogler, Geza F.
    Hsiao-Wecksler, Elizabeth T.
    [J]. 2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 624 - 627
  • [48] Effect of Shoes on Stiffness and Energy Efficiency of Ankle-Foot Orthosis: Bench Testing Analysis
    Kobayashi, Toshiki
    Gao, Fan
    LeCursi, Nicholas
    Foreman, K. Bo
    Orendurff, Michael S.
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (06) : 460 - 463
  • [49] Instrumented Ankle-Foot Orthosis: Toward a Clinical Assessment Tool for Patient-Specific Optimization of Orthotic Ankle Stiffness
    Bolus, Nicholas B.
    Teague, Caitlin N.
    Inan, Omer T.
    Kogler, Geza F.
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2017, 22 (06) : 2492 - 2501
  • [50] A modified passive-dynamic ankle-foot orthosis: can it prevent amputation and arthrodesis in patients with ankle-foot trauma?
    Jonkergouw, Niels
    de Kruijff, Loes G. M.
    Bongers, Rogier E. G.
    Swaan, Michiel W.
    Holtslag, Herman R.
    van der Meer, Alfred
    van der Wurff, Peter
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2022, 142 (10) : 2719 - 2726