Accuracy of Eclipse Electron Macro Monte Carlo Dose Algorithm for Use in Bolus Electron Conformal Therapy

被引:0
|
作者
Carver, R. [1 ]
Popple, R. [2 ]
Antolak, J. [3 ]
Sprunger, C. [4 ]
Benhabib, S. [2 ]
Hogstrom, K. [1 ,4 ]
机构
[1] Mary Bird Perkins Canc Ctr, Baton Rouge, LA USA
[2] Univ Alabama Birmingham, Birmingham, AL USA
[3] Mayo Clin, Rochester, MN USA
[4] Louisiana State Univ, Baton Rouge, LA 70803 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-E-T-356
引用
收藏
页码:306 / 306
页数:1
相关论文
共 50 条
  • [11] Bolus Electron Conformal Therapy
    Antolak, J.
    Antolak, J.
    Kavanaugh, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E643 - E643
  • [12] Quantitative evaluation of dosimetric uncertainties in electron therapy by measurement and calculation using the electron Monte Carlo dose algorithm in the Eclipse treatment planning system
    Ali, Imad
    Alsbou, Nesreen
    Ahmad, Salahuddin
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (01):
  • [13] Benchmarking of Eclipse Electron Monte Carlo Dose Calculation Algorithm for Smaller Fields and Anthropomorphic Challenges
    Muller, L.
    Ahmad, S.
    Johnson, D.
    MEDICAL PHYSICS, 2018, 45 (06) : E430 - E431
  • [14] Dosemetric Uncertainties in the Electron Monte Carlo Dose Calculation Algorithm in the Eclipse Treatment Planning System
    Kendall, E.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2018, 45 (06) : E249 - E250
  • [15] Electron Monte Carlo Dose Calculation in Eclipse for Siemens Linear Accelerators
    Fix, M. K.
    Cygler, J. E.
    Vandervoort, E.
    Karle, H.
    Tertel, J.
    Frei, D.
    Volken, W.
    Born, E. J.
    Manser, P.
    MEDICAL PHYSICS, 2009, 36 (06) : 2621 - +
  • [16] Evaluation of the eclipse electron Monte Carlo dose calculation for small fields
    Xu, Zhigang
    Walsh, Sarah E.
    Telivala, Tejas P.
    Meek, Allen G.
    Yang, Guozhen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (03): : 75 - 85
  • [17] Electron Monte Carlo Dose Calculation in Eclipse for Elekta Linear Accelerators
    Fix, M. K.
    Frei, D.
    Volken, W.
    Neuenschwander, H.
    Born, E. J.
    Manser, P.
    MEDICAL PHYSICS, 2010, 37 (06) : 3283 - +
  • [18] Evaluation of an electron Monte Carlo dose calculation algorithm for electron beams
    Hu, Ye Angela
    Song, Haijun
    Chen, Zhe
    Zhou, Sumin
    Yin, Fang-Fang
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (03): : 1 - 15
  • [19] Validation and Clinical Experience of Eclipse Electron Monte Carlo Algorithm (EMC)
    Pokharel, S.
    Rana, S.
    MEDICAL PHYSICS, 2014, 41 (06) : 303 - 303
  • [20] Development of Electron Dose Calculation Engine and Optimiaation Algorithm to Implement a Bolus Optimizaiton System for Clinical Electron Conformal Therapy
    Chung, J. B.
    Kang, S. W.
    Cho, W.
    Han, M. J.
    MEDICAL PHYSICS, 2024, 51 (10) : 7953 - 7953