Near infrared heterodyne radiometer for continuous measurements of atmospheric CO2 column concentration

被引:18
|
作者
Deng, Hao [1 ,2 ]
Yang, Chenguang [1 ]
Wang, Wei [1 ]
Shan, Changgong [1 ,2 ]
Xu, Zhenyu [1 ]
Chen, Bing [1 ]
Yao, Lu [1 ,2 ]
Hu, Mai [1 ]
Kan, Ruifeng [1 ,2 ,3 ]
He, Yabai [1 ]
机构
[1] Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Key Lab Environm Opt & Technol, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Hefei 230022, Anhui, Peoples R China
[3] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Jilin, Peoples R China
关键词
Carbon dioxide; Column concentration; Laser heterodyne radiometer (LHR); Distributed feedback (DFB) diode laser; COOLING RATES; SPECTRORADIOMETRY; EMISSION; NORTHERN; METHANE; FLUXES;
D O I
10.1016/j.infrared.2019.06.002
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report a laser heterodyne radiometer (LHR) using a distributed feedback (DFB) diode laser operating in the near infrared region as the local oscillator to continuously measure atmospheric carbon dioxide (CO2) column concentration, which has a spectral resolution of 0.09 cm(-1). The measurements for three consecutive days show that the averaged CO(2 )column concentration are 411.5 ppm, 410.4 ppm and 409.5 ppm, respectively. The averaged measurement precision is 1.6% by analyzing the standard deviation of CO2 column concentration. The relative error of 0.3% is estimated by comparing to CO2 average column concentration derived from GOSAT data on October 31, 2018 during the same measurement period. Moreover, the CO2 results are in good agreement with those measured by the ground-based Fourier transform spectrometer (FTS) simultaneously. The results prove the capacity and the reliability of the developed near infrared LHR to monitor the time series of regional CO2.
引用
收藏
页码:39 / 44
页数:6
相关论文
共 50 条
  • [41] Near miss: the importance of the natural atmospheric CO2 concentration to human historical evolution
    David Archer
    Climatic Change, 2016, 138 : 1 - 11
  • [42] Near miss: the importance of the natural atmospheric CO2 concentration to human historical evolution
    Archer, David
    CLIMATIC CHANGE, 2016, 138 (1-2) : 1 - 11
  • [43] INTERANNUAL VARIATION OF ATMOSPHERIC CO2 CONCENTRATION
    THOMPSON, ML
    ENTING, IG
    PEARMAN, GI
    HYSON, P
    JOURNAL OF ATMOSPHERIC CHEMISTRY, 1986, 4 (01) : 125 - 155
  • [44] Development of a laser heterodyne spectroradiometer for high-resolution measurements of CO2, CH4, H2O and O2 in the atmospheric column
    Deng, Hao
    Yang, Chenguang
    Xu, Zhenyu
    Li, Mingxing
    Huang, An
    Yao, Lu
    Hu, Mai
    Chen, Bing
    He, Yabai
    Kan, Ruifeng
    Liu, Jianguo
    OPTICS EXPRESS, 2021, 29 (02) : 2003 - 2013
  • [45] Ability analysis of spatial heterodyne spectrometer in atmospheric CO2 detection
    Wu J.
    Wang X.
    Fang Y.
    Xiong W.
    Shi H.
    Qiao Y.
    Guangxue Xuebao/Acta Optica Sinica, 2011, 31 (01):
  • [46] An attempt at estimating Paris area CO2 emissions from atmospheric concentration measurements
    Breon, F. M.
    Broquet, G.
    Puygrenier, V.
    Chevallier, F.
    Xueref-Remy, I.
    Ramonet, M.
    Dieudonne, E.
    Lopez, M.
    Schmidt, M.
    Perrussel, O.
    Ciais, P.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2015, 15 (04) : 1707 - 1724
  • [47] Traceability in routine chemical measurements: an example of application in the determination of CO2 at atmospheric concentration
    M. Sega
    Margherita Plassa
    Elena Amico di Meane
    Accreditation and Quality Assurance, 2001, 6 : 306 - 309
  • [48] On the statistical optimality of CO2 atmospheric inversions assimilating CO2 column retrievals
    Chevallier, F.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2015, 15 (19) : 11133 - 11145
  • [49] CORRECTING AIRBORNE SCANNING INFRARED RADIOMETER MEASUREMENTS FOR ATMOSPHERIC EFFECTS
    BOUDREAU, RD
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1973, 54 (04): : 292 - 292
  • [50] Traceability in routine chemical measurements:: an example of application in the determination of CO2 at atmospheric concentration
    Sega, M
    Plassa, M
    de Meane, EA
    ACCREDITATION AND QUALITY ASSURANCE, 2001, 6 (07) : 306 - 309