Biomechanical and histological evaluation of four different implant macrogeometries in the early osseointegration process: An in vivo animal study

被引:8
|
作者
Gehrke, Sergio Alexandre [1 ,2 ]
Aramburu Junior, Jaime [1 ]
Treichel, Tiago Luis Eirles [3 ]
Dedavid, Berenice Anina [4 ]
机构
[1] Univ Catolica Murcia, Dept Biotechnol, Murcia 30107, Spain
[2] Biotecnos Technol & Sci, Dept Res, Montevideo 11100, Uruguay
[3] Univ Rio Verde, Fac Med Vet, Dept Surg, Rio Verde, Brazil
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, RS, Brazil
关键词
Implant macrogeometry; Implant stability; Osseointegration; Titanium implants; PRIMARY STABILITY; DENTAL IMPLANTS; SURFACE-MORPHOLOGY; PLACEMENT TORQUE; MACRO-DESIGN; DIMENSION; RABBIT;
D O I
10.1016/j.jmbbm.2021.104935
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to evaluate the effects of implant macrogeometry on the early period of the osseointegration process, comparing four different implant models through biomechanical and histological analysis after implantation in rabbit tibiae. Twenty New Zealand rabbits were used, evaluated at two different times (21 and 28 days) after installation of the implant. Eighty implants with different macrogeometries were used, forming four groups (n = 20 per group): cylindrical implants 04.1 mm and 8 mm in length (STRc group); cylindrical-conical implants 04.1 mm and 8 mm in length (STRt group); tapered implants 04.3 mm and 8 mm in length (NOBt group); and tapered implants with healing chambers 04.0 mm and 8 mm in length (MAEt group). Ten samples from each group were analyzed at each proposed time. The initial implant stability quotient (ISQ) was measured by resonance frequency analysis, both at the time of installation and at the time of sacrifice. In the histological sections, the percentage of bone-implant contact (BIC%), newly formed bone, osteoid matrix, and medullary spaces were measured in the pre-determined cortical and medullary bone portion for each sample. The three tapered implant groups (STRt, NOBt, and MAEt) showed higher values for the analyzed parameters in the early osseointegration period, in comparison with the cylindrical implant group (STRc). In all parameters, the three tapered groups showed no difference (p 0.05); however, all three tapered groups presented significant differences, when compared to the cylindrical group (p < 0.05). No correlation was detected between the parameters analyzed. Within the limitations of the present study, in all parameters analyzed, the tapered implants demonstrated greater results when compared to the cylindrical implants.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Comparison of four different techniques for performing an osteotomy A BIOMECHANICAL, RADIOLOGICAL AND HISTOLOGICAL STUDY ON RABBITS TIBIAS
    Elmadag, M.
    Uzer, G.
    Yildiz, F.
    Erden, T.
    Bilsel, K.
    Buyukpinarbasili, N.
    Usumez, A.
    Bozdag, E.
    Sen, C.
    BONE & JOINT JOURNAL, 2015, 97B (12): : 1628 - 1633
  • [32] Biomechanical Evaluation of a Femoral Implant for Hip Resurfacing Arthroplasty in Dogs: An Ex Vivo Study
    Perez Neto, Daniel M. G.
    Muzzi, Leonardo A. L.
    Santos, Fabio L.
    Muzzi, Ruthnea A. L.
    Kawamoto, Fernando Y. K.
    Mesquita, Luciane R.
    Minto, Bruno W.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2024,
  • [33] Evaluation of bone turnover after bisphosphonate withdrawal and its influence on implant osseointegration: an in vivo study in rats
    Fausto Frizzera
    Mario Henrique Arruda Verzola
    Rafael Scaf de Molon
    Guilherme Jose Pimentel Lopes de Oliveira
    Gabriela Giro
    Luis Carlos Spolidorio
    Rosa Maria Rodrigues Pereira
    Sotirios Tetradis
    Joni Augusto Cirelli
    Silvana Regina Peres Orrico
    Clinical Oral Investigations, 2019, 23 : 1733 - 1744
  • [34] Evaluation of bone turnover after bisphosphonate withdrawal and its influence on implant osseointegration: an in vivo study in rats
    Frizzera, Fausto
    Arruda Verzola, Mario Henrique
    de Molon, Rafael Scaf
    Pimentel Lopes de Oliveira, Guilherme Jose
    Giro, Gabriela
    Spolidorio, Luis Carlos
    Rodrigues Pereira, Rosa Maria
    Tetradis, Sotirios
    Cirelli, Joni Augusto
    Peres Orrico, Silvana Regina
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (04) : 1733 - 1744
  • [35] Evaluation of a New Titanium-Zirconium Dental Implant: A Biomechanical and Histological Comparative Study in the Mini Pig
    Gottlow, Jan
    Dard, Michel
    Kjellson, Fred
    Obrecht, Marcel
    Sennerby, Lars
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (04) : 538 - 545
  • [36] Comparison between four different suture configurations for rotator cuff repair: a biomechanical animal study
    Haroun, Yahia
    Sobhy, Mohamed H.
    Khater, Hany A.
    Khater, Ahmad H.
    SICOT-J, 2024, 10
  • [37] Impact of Different Titanium Implant Thread Designs on Bone Healing: A Biomechanical and Histometric Study with an Animal Model
    Alexandre Gehrke, Sergio
    Eliers Treichel, Tiago Luis
    Perez-Diaz, Leticia
    Calvo-Guirado, Jose Luis
    Aramburu, Jaime, Jr.
    Mazon, Patricia
    de Aza, Piedad N.
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (06)
  • [38] A Comparative Analysis Regarding the Osseointegration of Immediate Loaded Implants Using Two Different Implant Site Preparations: Erbium:Yttrium-Aluminum-Garnet Laser Versus Surgical Conventional Way-An In Vivo and Histological Animal Study
    Semez, Gianfranco
    Cescato, Alberto
    Luca, Ruxandra Elena
    Tonetti, Luca
    Todea, Darinca Carmen
    PHOTOBIOMODULATION PHOTOMEDICINE AND LASER SURGERY, 2021, 39 (01) : 70 - 80
  • [39] Biomechanical and Morphometric Evaluation of a Strontium-Incorporated Implant and Four Commercially Available Implants: A Study in Rabbits
    Wu, Ye-feng
    Lin, Guo-fen
    Zhang, Lie-fen
    He, Fu-ming
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (03) : 531 - 541
  • [40] Biomechanical evaluation of augmented and nonaugmented primary repair of the anterior cruciate ligament: an in vivo animal study
    Helmut Seitz
    Wofgang Pichl
    Veronika Matzi
    Thomas Nau
    International Orthopaedics, 2013, 37 : 2305 - 2311