Biomechanical and histological evaluation of four different implant macrogeometries in the early osseointegration process: An in vivo animal study

被引:8
|
作者
Gehrke, Sergio Alexandre [1 ,2 ]
Aramburu Junior, Jaime [1 ]
Treichel, Tiago Luis Eirles [3 ]
Dedavid, Berenice Anina [4 ]
机构
[1] Univ Catolica Murcia, Dept Biotechnol, Murcia 30107, Spain
[2] Biotecnos Technol & Sci, Dept Res, Montevideo 11100, Uruguay
[3] Univ Rio Verde, Fac Med Vet, Dept Surg, Rio Verde, Brazil
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, RS, Brazil
关键词
Implant macrogeometry; Implant stability; Osseointegration; Titanium implants; PRIMARY STABILITY; DENTAL IMPLANTS; SURFACE-MORPHOLOGY; PLACEMENT TORQUE; MACRO-DESIGN; DIMENSION; RABBIT;
D O I
10.1016/j.jmbbm.2021.104935
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to evaluate the effects of implant macrogeometry on the early period of the osseointegration process, comparing four different implant models through biomechanical and histological analysis after implantation in rabbit tibiae. Twenty New Zealand rabbits were used, evaluated at two different times (21 and 28 days) after installation of the implant. Eighty implants with different macrogeometries were used, forming four groups (n = 20 per group): cylindrical implants 04.1 mm and 8 mm in length (STRc group); cylindrical-conical implants 04.1 mm and 8 mm in length (STRt group); tapered implants 04.3 mm and 8 mm in length (NOBt group); and tapered implants with healing chambers 04.0 mm and 8 mm in length (MAEt group). Ten samples from each group were analyzed at each proposed time. The initial implant stability quotient (ISQ) was measured by resonance frequency analysis, both at the time of installation and at the time of sacrifice. In the histological sections, the percentage of bone-implant contact (BIC%), newly formed bone, osteoid matrix, and medullary spaces were measured in the pre-determined cortical and medullary bone portion for each sample. The three tapered implant groups (STRt, NOBt, and MAEt) showed higher values for the analyzed parameters in the early osseointegration period, in comparison with the cylindrical implant group (STRc). In all parameters, the three tapered groups showed no difference (p 0.05); however, all three tapered groups presented significant differences, when compared to the cylindrical group (p < 0.05). No correlation was detected between the parameters analyzed. Within the limitations of the present study, in all parameters analyzed, the tapered implants demonstrated greater results when compared to the cylindrical implants.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Can changes in implant macrogeometry accelerate the osseointegration process?: An in vivo experimental biomechanical and histological evaluations
    Alexandre Gehrke, Sergio
    Aramburu, Jaime Junior
    Perez-Diaz, Leticia
    do Prado, Tales Dias
    Dedavid, Berenice Anina
    Mazon, Patricia
    De Aza, Piedad N.
    PLOS ONE, 2020, 15 (05):
  • [2] The effect of different implant macrogeometries and surface treatment in early biomechanical fixation: An experimental study in dogs
    Coelho, Paulo G.
    Granato, Rodrigo
    Marin, Charles
    Teixeira, Hellen S.
    Suzuki, Marcelo
    Valverde, Guilherme B.
    Janal, Malvin N.
    Lilin, Tomas
    Bonfante, Estevam A.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (08) : 1974 - 1981
  • [3] Biomechanical and histological evaluation of the osseointegration capacity of two types of zirconia implant
    Han, Jian-min
    Hong, Guang
    Lin, Hong
    Shimizu, Yoshinaka
    Wu, Yuhan
    Zheng, Gang
    Zhang, Hongyu
    Sasaki, Keiichi
    International Journal of Nanomedicine, 2016, 11 : 6507 - 6516
  • [4] Biomechanical and histological evaluation of four different titanium implant surface modifications: an experimental study in the rabbit tibia
    Luis Calvo-Guirado, Jose
    Satorres, Marta
    Negri, Bruno
    Ramirez-Fernandez, Piedad
    Eduardo Mate-Sanchez, Jose
    Delgado-Ruiz, Rafael
    Gomez-Moreno, Gerardo
    Abboud, Marcus
    Romanos, Georgios E.
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (05) : 1495 - 1505
  • [5] Clinical and histological efficacy of a new implant surface in achieving early and stable osseointegration: An in vivo study
    Nevins, Myron
    Chen, Chia-Yu
    Khang, Wahn
    Kim, David M.
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2024, 17 (03)
  • [6] Evaluation of implant osseointegration by nonlinear dynamic response: In vivo animal studies.
    Ramp, LC
    Reddy, MS
    Jeffcoat, RL
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 2518 - 2518
  • [7] Biomechanical Evaluation of Implant Osseointegration After Guided Bone Regeneration With Different Bone Grafts
    Gunes, Nedim
    Gul, Mehmet
    Dundar, Serkan
    Tekin, Samet
    Bozoglan, Alihan
    Ozcan, Erhan Cahit
    Karasu, Necmettin
    Toy, Vesile Elif
    Bingul, Muhammet Bahattin
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (04) : 1545 - 1548
  • [8] Biomechanical and Histological Analysis of Titanium (Machined and Treated Surface) Versus Zirconia Implant Materials: An In Vivo Animal Study
    Alexandre Gehrke, Sergio
    Carlos Prados-Frutos, Juan
    Prados-Privado, Maria
    Luis Calvo-Guirado, Jose
    Aramburu Junior, Jaime
    Perez-Diaz, Leticia
    Mazon, Patricia
    Manuel Aragoneses, Juan
    De Aza, Piedad N.
    MATERIALS, 2019, 12 (06):
  • [9] Influence of implant surface topography on early osseointegration: A histological study in human jaws
    Shibli, Jamil Awad
    Grassi, Sauro
    de Figueiredo, Luciene Cristina
    Feres, Magda
    Marcantonio, Elcio, Jr.
    Iezzi, Giovanna
    Piattelli, Adriano
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2007, 80B (02) : 377 - 385
  • [10] Osseointegration improves bone–implant interface of pedicle screws in the growing spine: a biomechanical and histological study using an in vivo immature porcine model
    Kanako Shiba
    Hiroshi Taneichi
    Takashi Namikawa
    Satoshi Inami
    Daisaku Takeuchi
    Yutaka Nohara
    European Spine Journal, 2017, 26 : 2754 - 2762