Non-normal distribution of radon and residual radon and short-term abnormal precursors of residual radon before major earthquakes

被引:3
|
作者
Jin, Xiaobing [1 ]
Bu, Junwei [5 ]
Qiu, Guilan [2 ]
Ma, Li [5 ]
Chen, Zhongming [5 ]
Chen, Tao [6 ]
Wu, Junwei [7 ]
Pan, Bo [7 ]
Ji, Hai [7 ]
Tian, Jingxuan [3 ]
Wu, Xiaoxiao [4 ]
Li, Zhipeng [2 ]
Zhang, Liang [1 ]
Liu, Chang [5 ]
Zhao, Xiaoli [1 ]
Cheng, Xiang [1 ]
机构
[1] Sichuan Meteorol Disaster Prevent Technol Ctr, Chengdu 610000, Sichuan, Peoples R China
[2] Sichuan Earthquake Bur, Chengdu 610000, Sichuan, Peoples R China
[3] Univ Hong Kong, Dept Mech Engn, Pokfulam Rd, Hong Kong, Peoples R China
[4] Hong Kong Univ Sci & Technol, Dept Phys, Kowloon, Clear Water Bay, Hong Kong, Peoples R China
[5] Sichuan Meteorol Bur, Chengdu 610072, Sichuan, Peoples R China
[6] Chinese Acad Scicences, Natl Space Sci Ctr, Zhongguancun Nanertiao 1,POB 8701, Beijing 100190, Peoples R China
[7] Chengdu Meteorol Bur, Chengdu 610000, Sichuan, Peoples R China
关键词
Precursor; Radon escaped from groundwater (C-Rn); Residual radon (C-Rr); Abnormaly; Non-normal distribution; GAS; GENERATION; ANOMALIES; EMANATION; CANNOT;
D O I
10.1007/s12145-022-00842-3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The basis of short-term earthquake prediction is the identification of reliable precursors. Anomaly of radon concentration escaped from groundwater (C-Rn) is often used as a traditional earthquake precursor. However, the thresholds of anomaly are still controversial. Using the data series of long-term C-Rn, the data series of residual radon concentration (C-Rr) was obtained to exclude periodic environmental interference, and the distribution of long-term C-Rn and C-Rr was tested. It is verified that the distribution of C-Rn and C-Rr does not conform with the traditional default normal distribution. Therefore, the box plot of non-normally distributed is used to redefine the anomaly threshold. The temporal and spatial analysis results of C-Rn and C-Rr show that before the Wenchuan, Lushan and Jiuzhaigou earthquakes, C-Rn and C-Rr show similar short-term anomaly patterns as follows: (1) With the approach of main shocks, the C-Rn and C-Rr near the epicenter/fault zone increase sharply and are accompanied by obvious positive anomalies. (2) The duration of anomalies is closely related to the location of the epicenter/fault zone and the observation station. (3) The anomaly of C-Rr which filtered out periodic environmental disturbance can reflect the abnormal precursor caused by tectonic geological activity before earthquake more accurately than the C-Rn anomaly. (4) The non-normal anomaly analysis method is more consistent with the mathematical definition than the normal distribution anomaly analysis method. Therefore, analyzing the abnormal threshold of residual radon which is non-normally distributed may be a reliable method for the analysis of radon anomalies before large earthquakes.
引用
收藏
页码:2495 / 2511
页数:17
相关论文
共 50 条
  • [21] The variations of radon and its short-term decay products in living rooms
    Jasaitis, D
    Peciuliene, M
    Girgzdys, A
    6TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING, VOLS 1 AND 2, 2005, : 114 - 117
  • [22] Quantification of the response delay of mobile radon-in-air detectors applied for detecting short-term fluctuations of radon-in-water concentrations
    E. Petermann
    M. Schubert
    The European Physical Journal Special Topics, 2015, 224 : 697 - 707
  • [23] Quantification of the response delay of mobile radon-in-air detectors applied for detecting short-term fluctuations of radon-in-water concentrations
    Petermann, E.
    Schubert, M.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2015, 224 (04): : 697 - 707
  • [24] PREDICTION OF LONG-TERM INDOOR RADON CONCENTRATION BASED ON SHORT-TERM MEASUREMENTS
    Stojanovska, Zdenka
    Ivanova, Kremena
    Bossew, Peter
    Boev, Blazo
    Zunic, Zora S.
    Tsenova, Martina
    Curguz, Zoran
    Kolarz, Predrag
    Zdravkovska, Milka
    Ristova, Mimoza
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2017, 32 (01): : 77 - 84
  • [25] Radon measurement uncertainty: Comparison between passive short-term and active measurement
    Reimer, G. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 277 (01) : 249 - 251
  • [26] Radon measurement uncertainty: Comparison between passive short-term and active measurement
    G. M. Reimer
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 277 : 249 - 251
  • [27] Do the earth tides have an influence on short-term variations in radon concentration?
    Barnet, I
    Prochazka, J
    Skalsky, L
    RADIATION PROTECTION DOSIMETRY, 1997, 69 (01) : 51 - 60
  • [28] Comment on 'An etched track detector for short-term screening measurements of radon' Reply
    Ibrahimi, Z-F
    Miles, J. C. H.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2009, 29 (03) : 450 - 451
  • [29] Comparison between long-term and short-term measurements for indoor radon risk mapping
    Tondeur, F
    Gerardy, I
    Natural Radiation Environment VII, 2005, 7 : 598 - 603
  • [30] SHORT-TERM ANNUAL VARIATIONS OF RADON CONCENTRATION IN WORKPLACES: SOME RESULTS IN A RESEARCH INSTITUTE
    Venoso, G.
    Ampollini, M.
    Antignani, S.
    Caprio, M.
    Carpentieri, C.
    Di Carlo, C.
    Bochicchio, F.
    RADIATION PROTECTION DOSIMETRY, 2020, 191 (02) : 138 - 143